HomeMy WebLinkAboutSDP200800051 Review Comments Minor Amendment 2008-04-28�pF .AI,g COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: Innovation Dr. Entran. Improvements [SDP200800051, WP0200800010] Primary Contact: Mike Stumbaugh, UVA Foundation [email: mrs6c @virginia.edu] Plan Preparer: David Anhold, Anhold Associates [email: danhold @hu heg s.net] Plan received date: 18 Feb 2008 (ESC plans) 25 Mar 2008 (MIA plans) Date of comments: 21 Mar 2008 (ESC plans) 28 Apr 2008 (MIA plans) Reviewer: Jonathan Sharp [phone: 566 -2578] A. Minor Amendment (Apr 28 2008 comments) 1. Trees cannot be located in drainage easements. Easements do not have to be centered over pipes. The lines can be anywhere within the center third of the easement. Drainage easements must be recorded prior to minor amendment approval. 2. The proposed ditch must be in a drainage easement to the property line. 3. The labels for "top of wall" are labeled `BW" instead of "TW" 4. Slopes steeper than 3:1 require non grassed low maintenance ground cover. 5. Please provide inlet calculations and ditch calculations. 6. Please provide inlet shaping in each proposed manhole /inlet. 7. Walls over 4 feet in height require safety railing. Engineering recommends lowering the wall to 4 feet in height. 8. This plan is a minor amendment to SDP200600107 — Northern Fire and Rescue Station #2 — Final. B. Erosion Control Plan (Mar 212008 comments) 9. A minor amendment to the existing site plan on site is required and must be approved prior to a grading permit can be issued for the proposed improvements. 10. The ESC narrative refers to a separate Stormwater Management Plan for this site. I do not see any proposed Stormwater Management. Please clarify. 11. Please provide accurate current existing topography at the time of submittal, including all existing site features, and any recent disturbances, all at a legible scale. This area is currently being disturbed for the ESC plan associated with the Northern Fire Station. The grading permit appears to include areas proposed to be disturbed with this submittal. This plan should be coordinated with the Northern Fire Station Plan: SDP200600107 and WP0200600034. The plan should also be coordinated with any plans for the Lewis and Clark Road Plans/ESC /SWM plans. 12. Please provide the date and source of the topographic information: All topography should be at least visually field verified. The topography in the field may be changed due to the current work going on at the site. 13. Please provide a benchmark location, elevation and datum for topography. 14. Please show all existing easements (access, drainage, sight, sanitary easements, etc.) with deed book references, locations and dimensions. 15. Please show the County ESC notes on the plans, verbatim. 16. Please show a construction entrance (CE) on the plans. Albemarle County Community Development Engineering Review Comments Page 2 of 2 17. Please show the dust control symbol (DC) on the plans. 18. Please show the temporary (TS) and permanent (PS) stabilization symbol on the plans. 19. Please show existing drainage divides on the plans. 20. Please show a stockpile location on the plans. 21. Please show a staging and parking area on the plans. 22. Please provide a paved construction entrance detail on the plans. A copy of the detail can be found following the review comments. 23. An E &S bond will be computed by the County once the plans have been approved.