HomeMy WebLinkAboutSDP200800059 Review Comments Major Amendment, Preliminary Plan 2008-05-07II COMMONWEALTH OF VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper, Virginia 22701 David S. Ekern, P.E. VirginiaDOT.org COMMISSIONER May 7, 2008 Mr. Glenn Brooks Department of Engineering and Development 401 McIntire Rd. Charlottesville, VA 22902 Subject: Site Review Meeting Comments May 8, 2008 site review meeting Dear Mr. Brooks: Below are VDOT's comments on the Site Plans for the May 8, 2008 Site Review Committee Meeting: SDP - 2008 -00059 Olinva and sons -Maior (Megan Yaniglos) • No comments SDP - 2008 -00060 First Church of the Nazarene - Preliminary (Summer Frederick) • VDOT has previously reviewed the configuration and location of the turn land and entrance and it does appear to be in accordance with past meetings and comments from VDOT. • The construction of VDOT project 0022 - 002 -104 will begin May 12th, 2008. This plan needs to, and appears to be, designed to the changes by the intersection project. Final plans should show the proposed intersection project and how the proposed turn lane and entrance will tie in to that project. VDOT has provided the developer the survey data and that needs to be shown on the final plan. SDP - 2008 -00061 Easrlysville Business Park -Final (Summer Frederick) • The sag vertical curve at station 21 +44 needs to have a minimum k value of 17. • Outlet protection at Al should be class II rip rap SDP - 2008 -00064 Georgetown/Hydraulic Professional Offices - Preliminary (Lisa Glass) • Previous comments have been made for ZMA- 2006 -00014 that still need to be addressed and are: C--,- �i'EARS OF Tit AHSPORiAikOH El[C4LEHCE a 9-D G 2 0 0 6 • This plan must be coordinated with the VDOT project for Georgetown Road. The project manager has been forwarded a copy of this plan. The applicants engineer should contact VDOT for coordination. • It is very undesirable to have the entrance in the functional area of the intersection, however, a previous meeting with the engineer and the county determined that this is the best solution at this site for Hydraulic Road. The only other option is to access the site from Georgetown Road. • The plan needs to show the intersection of 656 and 743 and show details of turn movements, lane widths, storage lengths, etc. All projected and existing traffic needs to be shown on the plan. • Sight lines need to be shown for the entrance to the site and also for the existing intersection at 656/743. • Vehicles heading northbound on Hydraulic trying to turn left into the site is a dangerous situation and needs to be addressed with the site plan. • Proposed traffic needs to be shown on the site plan to determine is a Chapter 527 study needs to be done. SDP - 2008 -00065 Moser Radiation Therapy Ctr -Maior (Gerald Gatobu) • LTACH access management plan should be completed prior to any site plan approvals. SDP - 2008 -00066 Hunters Way Site Plan Amendment -Maior (Lisa K Glass) • The plan needs to include calculations for outlet velocity on YD 1 and outlet protection details. Also include ditch calculations. SUB - 2008 -00102 Handley Farm Estates(10 -19) lots -Final (Megan Yaniglos) • No comments. Please request the applicants provide a written description of revisions with re- submissions. If you have any questions or comments, please contact me prior to sharing these comments with the applicants. Sincerely, Joel DeNunzio, P.E. Residency Program Manager VDOT Charlottesville Residency 434 - 293 -0011 cc Bill Fritz, David Benish, Juan Wade, Elaine Echols, Joan McDowell, Judith Wiegand, Margaret Maliszewski, David Pennock, Francis McCall, Jon Sharp, Summer Frederick, Patrick Lawrence, and John Giometti