HomeMy WebLinkAboutSDP200800060 Review Comments No Submittal Type Selected 2008-05-07II
COMMONWEALTH OF VIRGINIA
DEPARTMENT OF TRANSPORTATION
1601 Orange Road
Culpeper, Virginia 22701
David S. Ekern, P.E. VirginiaDOT.org
COMMISSIONER
May 7, 2008
Mr. Glenn Brooks
Department of Engineering and Development
401 McIntire Rd.
Charlottesville, VA 22902
Subject: Site Review Meeting Comments May 8, 2008 site review meeting
Dear Mr. Brooks:
Below are VDOT's comments on the Site Plans for the May 8, 2008 Site Review Committee
Meeting:
SDP - 2008 -00059 Olinva and sons -Maior (Megan Yaniglos)
• No comments
SDP - 2008 -00060 First Church of the Nazarene - Preliminary (Summer Frederick)
• VDOT has previously reviewed the configuration and location of the turn land and
entrance and it does appear to be in accordance with past meetings and comments from
VDOT.
• The construction of VDOT project 0022 - 002 -104 will begin May 12th, 2008. This plan
needs to, and appears to be, designed to the changes by the intersection project. Final
plans should show the proposed intersection project and how the proposed turn lane and
entrance will tie in to that project. VDOT has provided the developer the survey data and
that needs to be shown on the final plan.
SDP - 2008 -00061 Easrlysville Business Park -Final (Summer Frederick)
• The sag vertical curve at station 21 +44 needs to have a minimum k value of 17.
• Outlet protection at Al should be class II rip rap
SDP - 2008 -00064 Georgetown/Hydraulic Professional Offices - Preliminary (Lisa Glass)
• Previous comments have been made for ZMA- 2006 -00014 that still need to be addressed
and are:
C--,-
�i'EARS OF
Tit
AHSPORiAikOH El[C4LEHCE
a 9-D G 2 0 0 6
• This plan must be coordinated with the VDOT project for Georgetown Road. The project
manager has been forwarded a copy of this plan. The applicants engineer should contact
VDOT for coordination.
• It is very undesirable to have the entrance in the functional area of the intersection,
however, a previous meeting with the engineer and the county determined that this is the
best solution at this site for Hydraulic Road. The only other option is to access the site
from Georgetown Road.
• The plan needs to show the intersection of 656 and 743 and show details of turn
movements, lane widths, storage lengths, etc. All projected and existing traffic needs to
be shown on the plan.
• Sight lines need to be shown for the entrance to the site and also for the existing
intersection at 656/743.
• Vehicles heading northbound on Hydraulic trying to turn left into the site is a dangerous
situation and needs to be addressed with the site plan.
• Proposed traffic needs to be shown on the site plan to determine is a Chapter 527 study
needs to be done.
SDP - 2008 -00065 Moser Radiation Therapy Ctr -Maior (Gerald Gatobu)
• LTACH access management plan should be completed prior to any site plan approvals.
SDP - 2008 -00066 Hunters Way Site Plan Amendment -Maior (Lisa K Glass)
• The plan needs to include calculations for outlet velocity on YD 1 and outlet protection
details. Also include ditch calculations.
SUB - 2008 -00102 Handley Farm Estates(10 -19) lots -Final (Megan Yaniglos)
• No comments.
Please request the applicants provide a written description of revisions with re- submissions. If you
have any questions or comments, please contact me prior to sharing these comments with the
applicants.
Sincerely,
Joel DeNunzio, P.E.
Residency Program Manager
VDOT Charlottesville Residency
434 - 293 -0011
cc Bill Fritz, David Benish, Juan Wade, Elaine Echols, Joan McDowell, Judith Wiegand,
Margaret Maliszewski, David Pennock, Francis McCall, Jon Sharp, Summer Frederick, Patrick
Lawrence, and John Giometti