Loading...
HomeMy WebLinkAboutSUB200800102 Review Comments Final Plat 2008-06-11*-&A County of Albemarle Department of Community Development Memorandum To: Megan Yaniglos, Current Development Project Planner From: Phil Custer, Current Development engineering review Date: 4 June 2008 Subject: Handley Farm Final Plat (SUB- 2008 - 00102) The final plat for Handley Farm has been reviewed. The following comments are provided. 1. At the time of the expiration of the preliminary plat for this project, the applicant had approved road, ESC, SWM, and mitigation plans (WPO- 2007 -00047 and SUB - 2006 - 00243). It appears that the alignment of the road and lot layout is exactly the same as in the approved plans. Therefore, there are no SWM or road plan concerns for this preliminary plat. 2. The applicant needs to correctly show the stream buffers on the plan. Please refer to the county GIS -web application for latest buffer locations. The buffer disturbance shown on the plan will be allowed in accordance with sections 17 -320, 17 -321, and 17 -322 of the Water Protection Ordinance. A mitigation plan has already been submitted, approved, and bonded. (Rev. 1) Comment addressed. Stream buffers are shown correctly 3. A stream buffer is not needed over the pond in lots 2 and 3. (Rev. 1) Comment addressed. Stream buffers are shown correctly 4. Please show existing topography, critical slopes, and building sites. [14- 302A9, 14- 302Al2] (Rev. 1) Comment addressed. A map showing existing topography and critical slopes related to the building sites was provided as a supplement to the plat set. All critical slope disturbances were exempt when the preliminary plat was first reviewed under Section 18- 4.2.6.c. 5. (Rev. 1) Comment withdrawn. 6. (Rev. 1) A deed of dedication and easement is needed for all required drainage easements associated with this final plat. Please refer to the County's website for the most recent forms and procedural guidelines that need to be followed when submitting a deed of dedication and easement. The wording shown for the drainage easements on the Deed of Dedication and Easement needs to be exactly the same as the wording on the final plat. [DMJ 7. (Rev. 1) With the required changes, please make sure that the revision date of the revised plat matches the date of the plat shown on the deed of dedication and easement. /DM/ 8. (Rev. 1) Drainage easements from the streets must be dedicated to public use. [14 -431] 9. (Rev. 1) Please extend all drainage easements to the parent parcel property line or a stream. 10. (Rev. 1) The pond on Parcel 3 is not considered a SWM facility and will not require an easement and access path. 11. (Rev. 1) The stormwater management ponds on the residue parcel and lots 2 + 3 will require the following changes to their easements: a. Metes and bounds are needed to describe the easement location around both ponds and their accessways. The "IOft off of the pond surface level" is not adequate. The easements should also include other pertinent information like the spillways and embankments. b. The SWM easement on lots 2 and 3 should be shown on sheet 4. c. Labels on the final plat for the SWM facilities should match the referenced descriptions in the deed documents submitted to the county. File: E2_fpt_PBC_sub200800102