HomeMy WebLinkAboutSDP200800056 Review Comments Final Site Plan and Comps. 2008-07-16From: Hamidi, Ajmal [ Ajmal.Hamidi @VDOT.virginia.gov]
Sent: Wednesday, July 16, 2008 1:45 PM
To: Jonathan Sharp
Cc: Denunzio, Joel D., P.E.
Subject: SDP 200 -00056 WICKHAM POND BLOCK 2 FINAL SITE PLAN
SDP 200 -00056 WICKHAM POND BLOCK 2 FINAL SITE PLAN
Mr. Jonathon Sharp,
We have reviewed the above site plan and have the following comments:
• The two CG -11 commercial entrances to the site have widths of only 24 ft. Since
all the dumpsters for the site will be located in the underground parking garage,
trash - pickup trucks must use these entrances. It is doubtful that these entrances
can safely accommodate such single -unit (SU) trucks. We request that turning
movement diagrams be submitted to show they can.
• Profiles are needed for the two CG -11 commercial entrances to ensure that they
have acceptable grades.
• The pavement design for the commercial entrances should be provided.
• What appears to be a loading dock is shown in the plans on the southwest corner
of the site. For which vehicle has this loading area been design? A turning
movement diagram needs to be shown. This loading area should be designed so
that no vehicles on Wickham Way, a public road, need to back up into it.
• The intersection sight distance for the entrance at Wickham Way requires a line of
sight of 280 ft.; however, the plans show 100 ft. sight distance lines at this
intersection.
• Indicate which VDOT standard is proposed for the sidewalk ramp at the
intersection of Wickham Place and Wickham Way.
• The depth of the flow at the inlet should be given in Table 7 of sheet 7 to show
that no overtopping of the curb occurs.
If you have any questions regarding any of the above comments, please contact Joel
DeNunzio or me.
Thanks,
A.J. Hamidi
Tech III
Charlottesville Residency,
(434) 293 -0011