HomeMy WebLinkAboutSDP200800123 Review Comments Final Site Plan and Comps. 2008-08-26� OF AL
,. vIRGI1`IZP
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, Room 227
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4126
Project:
Plan preparer:
Owner or rep.:
Plan received date
Date of comments:
Reviewer:
Crozet Station/Phase I — Final
Ashley Cooper /Atwood Architects
CROZET SHOPPING CENTER LLC
05 August 2008
26 August 2008
Max Greene, Sam Brownfield
SDP200800123
[fax (434) 295 -24131
[fax unknown]
The Final Site Plan for Crozet Station, Phase 1 — Final submitted 05 August 2008 has received
Engineering review. The following design manual checklist items will be adequately addressed
prior to final approval.
Application information:
1. Submit a completed copy of the standard stormwater maintenance agreement and fee for
recordation for any stormwater management facilities. [17 -304E]
2. Copies of manufacturer's approval of the plan for any manufactured stormwater
management facilities. [Policy] Most structural SWMBMP distributors will verify
adequacy of design per their specifications and send a letter of approval /disapproval that
will become a part of County records.
Existing conditions information:
3. Show date and source of the topographic information: All topography should be at least
visually field verified by the designer within the last year [18- 32.6.6, 14 -302, Policy for
date]
4. Show all existing easements (access, drainage, sight, sanitary easements, etc.) with deed
book references, locations and dimensions [18- 32.6.6, 14 -302]
Proposed plan view information:
5. Show proposed slopes steeper than 3:1 have low maintenance (not grass) ground cover
specified on the plan [Policy]
Entrances and right -of -way improvements: [per VDOT Subdivision Street Requirements]
6. Show all entrances with a VDOT designation (PE -1, CG -9a, etc)
7. VDOT approval for any plan affecting public right -of -way.
Parking and circulation: [ 18 -4.12]
8. Show VDOT designations on all parking areas and travelways with curbing (CG -2, CG-
6)
Plan detail information:
Engineering Review Comments
Page 2 of 2
9. Show dumpster pad detail or specification to be a minimum 4" stone base and 6" concrete
of 3000psi at 28 days, or stronger, reinforced with a minimum grid of wire reinforcing or
#4 bars at 12" on center. [specs are policy]
10. Show details for any pipes or drainage structures through or under walls, showing
endwalls, casings, or structural measures to bridge pipes or structures.
Drainage profiles:
11. Show concrete inlet shaping (IS -1) specified on all structures with a 4' or greater drop.
12. Please make sure all inlet spreads are less than 10' from structure.
13. Please show overland relief path incase of inlet failure.
Water protection comments will be forthcoming due to submittal dates.
File: E1_fsp_MRG_Crozet Station, Phase 1, Final.doc