HomeMy WebLinkAboutSDP200800130 Review Comments No Submittal Type Selected 2008-09-11c��pF AL &FA9'P
�'IRGINIP
County of Albemarle
Department of Community Development
Memorandum
To: Ammy George
From: Gerald Gatobu, Senior Planner
Division: Zoning and Current Development
Date: Septemberl I'h 2008
Subject: SDP2008 -00130 University of Virginia Long Term Acute Care
The County of Albemarle Division of Zoning and Current Development will grant or recommend approval of
the final site plan referred to above once the following comments have been addressed: [Each comment is
preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise
specified.]
❑ 32.5.6 The preliminary /final site plan shall contain the following information:
❑ b. Written schedules or data as necessary to demonstrate that the site can accommodate the proposed use,
including:
Maximum number of employees: Add a note indicating the number of employees to be
working/employed at the hospital
Maximum height of all structures; Please send me the drawing that showed the building elevations I
used to determine the setbacks.
Schedule of parking including maximum amount required and amount provided; [will be
addressed by the Zoning Administrator per the parkin sg tudyl. Additionally, there are about two parking
spaces that extend beyond the property line of TMP 59 -23B into TMP 59 -23B 1.Section 4.12.16.b
Design of spaces. All parking spaces shall be designed so that no part of any vehicle will extend over
any lot line, right -of -way line, sidewalk, walkway, and driveway or aisle space. Please consider
redesigning the parking spaces close to the concrete loading and utility area.
LIGHTING PLAN REVIEW CHECKLIST
❑
Lumen level (3000 or more must be full cutoff) Cut Sheets have been
provided. This has been addressed.
❑
Bulb/lamp location (must be totally within house to be full cutoff)
Please note
Luminaire schedule
❑
Catalog # coordinated with cut sheets
Please include a luminaire schedule on the lighting plan. This will help
coordinate the catalog # with the cutsheets. The maintenance factor and
other variables can also be easily identified from a luminaire schedule.
F-1
Fixture quantity /types coordinated with quantity /types on lighting plan
It is difficult to locate fixtures and types on the lighting plan. The fixture
symbols and their associated labels are too small. Please make the fixture
symbols much bigger. Additionally, consider breaking down the fixtures
shown per the property or site e.g. Fixtures in TMP 59 -23B1 and those in
TMP59 -23B.
❑
Pole height/mounting height (ARB)
Not Applicable
❑
Colors /finishes (ARB)
Not applicable
❑
Tilt (must be 0 for full cutoff)
Please make sure all fixtures are full cut off,
Fixture locations
❑
Location conflicts with trees, utilities, etc.
The location of the lights must /shall not conflict with trees and utilities. The
boundary of TPM 59 -23B1 shown on the lighting plan is incorrect. A
boundary line adjustment was done and the lighting plan needs to reflect the
change.
❑
Coordination with other site plan sheets
The proposed fixtures need to be shown on other site plan sheets to make
sure that there are no conflicts.
❑
Shielding issues (freestanding signs, wall fixtures, etc.)
Please note that all future /intended freestanding signs, and proposed wall
fixtures must be shielded.
Photometric plan
Adjacent zoning
This does not raise any issues /comments
Property lines
As has been noted above, the boundary of TPM 59 -23B1 shown on the
lighting plan is incorrect. A boundary line adjustment was made and the
lighting lan needs to reflect the change.
❑
Excessive spillover
I have two areas close to the 30 foot access easement that may have some
excessive spillover i.e. >0.5 ootcandles.
❑
Excessive lighting levels (ARB)
Not applicable
❑
Maintenance factor = 1.0
Maintenance factor should be I.0
❑
Standard lighting notes
Thank you. (I found the note on page C2)
Landscape Plan Checklist
Section 32.7.9.6: STREET TREES
The Street tree requirement has been adequately met with this site plan.
Section 32.7.9.7: PARKING LOT LANDSCAPING
❑ (b) Interior landscaping: Exclusive of the requirements of section 32.7.9.7 (a) and (c), an area equal to
five (5) percent of the paved parking and vehicular circulation area shall be landscaped with trees or
shrubs.
❑ (b) This shall include one (1) large or medium shade tree per ten (10) parking spaces or portion
thereof, if five (5) spaces or more.
Thank you, this has been adequately addressed.
Section 32.7.9.9: TREE CANOPY
❑a. The foregoing notwithstanding, a minimum tree canopy shall be provided in accordance with this section.
"Tree canopy" or "tree cover" shall include all areas of coverage by plant material exceeding five (5) feet in
height at a maturity of ten (10) years after planting. Selection of species for planting shall be in accord with
section 32.7.9.4
❑ (a) Specifications for plantings shall be in accord with section 32.7.9.5
❑ (b) Existing trees to be preserved in accordance with section 32.7.9.4(b) together with trees required
under sections 32.7.9.6, 32.7.9.7 and 32.7.9.8 shall count toward satisfaction of the minimum tree
canopy.
❑b. The following minimum requirements shall apply:
❑1. Ten (10) percent tree canopy for a site to be developed with commercial, office or industrial
uses;
Thank you, this has been adequately addressed.
❑d. Where existing trees are maintained, a canopy bonus shall be granted as follows:
❑ 1. The area of canopy shall be calculated at ten (10) years of additional maturity;
❑2. The resultant area shall be multiplied by a factor of 1.25.
Thank you, this has been adequately addressed.
Comments
Symbols in the key (Planting schedule for 23B1) and the trees they represent on the site plan do not match.
HQSN- Oak leaf Hydrangea is shown as HQ
IVLH- Henry's Garnet Sweet spire is shown as ILH. The 10 year canopy allowance is incorrect.
QP- Pin Oak is shown as OP. 10 year coverage is incorrect.
VCC — Dwarf Korean Spice Viburnum is not in the plant canopy calculation table.
Please contact Gerald Gatobu at the Division of Zoning and Current Development at 296 -5832 ext.3385 for
further information.