Loading...
HomeMy WebLinkAboutSDP200800086 Review Comments Final Site Plan and Comps. 2008-06-18II COMMONWEALTH OF VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper, Virginia 22701 David S. Ekern, P.E. VirginiaDOT.org COMMISSIONER June 18, 2008 Mr. Glenn Brooks Department of Engineering and Development 401 McIntire Rd. Charlottesville, VA 22902 Subject: Site Review Meeting Comments June 19th, 2008 site review meeting Dear Mr. Brooks: Below are VDOT's comments on the Site Plans for the June 19th, 2008 Site Review Committee Meeting: SDP - 2006 -00079 Berkmar Business Park - Reinstatement (Francis MacCall) • There is no work proposed within the ROW for Berkmar Drive on this project. • The site is currently served by right and left turn lanes which should accommodate the traffic needs for this development. SDP - 2008 -00066 Hunters Way Site Plan Amendment- Maior(Lisa K Glass) • The projected traffic volumes need to be shown. • The existing entrance to the site does not meet the current minimum width standard for a commercial entrance. • Include calculations for pipe YD -1 outlet velocity and the ditch and culvert under the entrance. Rivanna Commercial Park/Phase II- Prelim. (Summer Frederick) • Show sight distances at the private entrance to Route 1570, Northside Drive. • Label the route number on Northside Drive. • Show the projected traffic form the sight and the existing traffic on Northside Dr and include warrants for right and left turn lanes. • The entrance must be designed in accordance with The Minimum Standards of Entrances to State Highways, the Road Design Manual, and the Road and Bridge Standards. • The profile at the connection to the state road needs to be on the plan. ��i'EARS OF Tit AHSPORiAikOH El[C4LEHCE a 9-D G 2 0 0 6 SDP - 2008 -00086 Willow Glenn -Final Francis MacCall) • Sheet 7 — the entrance to Route 606 needs to have a layout as shown in The Minimum Standards of Entrances to State Highways with adequate tapers and curb offsets. • Previous comments recommended a turn lane off Hollymead. • The pavement width on Heathrow Glenn Circle should be reduces in area where there will be no on street parking. The layout will cause a situation with parking in the driveways where the sidewalk will not and cannot be used because cars will be parked on the sidewalk. This are should be reconfigured. • The driveway entrances should be a CG -91) standard. • Material Reports for the con -span should be submitted to VDOT ASAP to ensure adequate design. • I need to complete the drainage review and will provide comments once I am finished. SUB - 2008 -00138 Westhall V lots 93 -125 Final (Patrick Lawrence) • It looks like there is a storm drain easement on the corner of lot 112 for pipe D -19 to D- 20 that needs to be labeled on sheet 3A. Please request the applicants provide a written description of revisions with re- submissions. If you have any questions or comments, please contact me prior to sharing these comments with the applicants. Sincerely, Joel DeNunzio, P.E. Residency Program Manager VDOT Charlottesville Residency 434 - 293 -0011 cc Bill Fritz, David Benish, Juan Wade, Elaine Echols, Joan McDowell, Judith Wiegand, Margaret Maliszewski, David Pennock, Francis McCall, Jon Sharp, Summer Frederick, Patrick Lawrence, and John Giometti