HomeMy WebLinkAboutSDP200800086 Review Comments Final Site Plan and Comps. 2008-06-18II
COMMONWEALTH OF VIRGINIA
DEPARTMENT OF TRANSPORTATION
1601 Orange Road
Culpeper, Virginia 22701
David S. Ekern, P.E. VirginiaDOT.org
COMMISSIONER
June 18, 2008
Mr. Glenn Brooks
Department of Engineering and Development
401 McIntire Rd.
Charlottesville, VA 22902
Subject: Site Review Meeting Comments June 19th, 2008 site review meeting
Dear Mr. Brooks:
Below are VDOT's comments on the Site Plans for the June 19th, 2008 Site Review Committee
Meeting:
SDP - 2006 -00079 Berkmar Business Park - Reinstatement (Francis MacCall)
• There is no work proposed within the ROW for Berkmar Drive on this project.
• The site is currently served by right and left turn lanes which should accommodate the
traffic needs for this development.
SDP - 2008 -00066 Hunters Way Site Plan Amendment- Maior(Lisa K Glass)
• The projected traffic volumes need to be shown.
• The existing entrance to the site does not meet the current minimum width standard for a
commercial entrance.
• Include calculations for pipe YD -1 outlet velocity and the ditch and culvert under the
entrance.
Rivanna Commercial Park/Phase II- Prelim. (Summer Frederick)
• Show sight distances at the private entrance to Route 1570, Northside Drive.
• Label the route number on Northside Drive.
• Show the projected traffic form the sight and the existing traffic on Northside Dr and
include warrants for right and left turn lanes.
• The entrance must be designed in accordance with The Minimum Standards of Entrances
to State Highways, the Road Design Manual, and the Road and Bridge Standards.
• The profile at the connection to the state road needs to be on the plan.
��i'EARS OF
Tit
AHSPORiAikOH El[C4LEHCE
a 9-D G 2 0 0 6
SDP - 2008 -00086 Willow Glenn -Final Francis MacCall)
• Sheet 7 — the entrance to Route 606 needs to have a layout as shown in The Minimum
Standards of Entrances to State Highways with adequate tapers and curb offsets.
• Previous comments recommended a turn lane off Hollymead.
• The pavement width on Heathrow Glenn Circle should be reduces in area where there
will be no on street parking. The layout will cause a situation with parking in the
driveways where the sidewalk will not and cannot be used because cars will be parked on
the sidewalk. This are should be reconfigured.
• The driveway entrances should be a CG -91) standard.
• Material Reports for the con -span should be submitted to VDOT ASAP to ensure
adequate design.
• I need to complete the drainage review and will provide comments once I am finished.
SUB - 2008 -00138 Westhall V lots 93 -125 Final (Patrick Lawrence)
• It looks like there is a storm drain easement on the corner of lot 112 for pipe D -19 to D-
20 that needs to be labeled on sheet 3A.
Please request the applicants provide a written description of revisions with re- submissions. If you
have any questions or comments, please contact me prior to sharing these comments with the
applicants.
Sincerely,
Joel DeNunzio, P.E.
Residency Program Manager
VDOT Charlottesville Residency
434 - 293 -0011
cc Bill Fritz, David Benish, Juan Wade, Elaine Echols, Joan McDowell, Judith Wiegand,
Margaret Maliszewski, David Pennock, Francis McCall, Jon Sharp, Summer Frederick, Patrick
Lawrence, and John Giometti