HomeMy WebLinkAboutSDP200800086 Review Comments Final Site Plan and Comps. 2008-08-20From: Amy Pflaum Sent: Wednesday, August 20, 2008 11:35 AM To: 'msilman @terraconceptspc.com' Subject: FW: SDP - 2008 -00086 Willow Glen Marty, I received Alan's out of office reply, so I am forwarding to you these new comments I just received from VDOT on the Willow Glen project. -Amy From: Hamidi, Ajmal [ mailto: Ajmal.Hamidi @VDOT.virginia.gov] Sent: Wednesday, August 20, 2008 10:59 AM To: Francis MacCall Cc: Denunzio, Joel D., P.E.; Philip Custer Subject: SDP - 2008 -00086 Willow Glen SDP - 2008 -00086 Willow Glen Francis MacCall, We have reviewed the road plans for the Willow Glen subdivision and have the following comments in addition to those provided for the June 19th, 2008 Site Review Committee Meeting: The curve data for the horizontal alignment of the public roads need to be provided, especially the centerline radii. The minimum centerline radius for a subdivision street with a design speed of 25 mph is 200'. The centerline radius of Heathrow Glen Circle appears to be approximately 177' (this dimension is not shown on sheet 10). The profiles should show vertical curves at the intersection tie -ins. Several intersection tie -ins currently do not show vertical curves connecting grade changes. For example, no vertical curve is shown where Willow Glen Drive ties into Dickerson Road, where Shannon Glen Drive ties into Towncenter Drive, or where Prestwick Glen Drive ties into Heathrow Glen Cycle. The radius of the curbs at the entrance to the site from Towncenter Drive is not shown. The radius must be sufficiently large so that the entrance would be able to accommodate its design vehicle. The sight distance lines need to be shown for the intersections within the subdivision. The intersection sight distance for roads with a 25 mph design speed is 280'. Of particular concern is the intersection of Shannon Glen Ct. and Heathrow Glen Circle which does not appear to have sufficient sight distance on the right side. The intersection sight distance lines for the entrance off Towncenter Drive also need to be shown. CG -12 standard ramps are needed at the intersection of Shannon Glen Court and Towncenter Drive. A flexible pavement design worksheet must be completed for each public subdivision road. This worksheet can be found on Appendix IV of the VDOT Pavement Design Guide. The typical road sections on sheets 16 and 17 show incorrect dimensions. For example, on the typical section C16 (Heathrow Glen Circle) the travelway width is shown as 25' even though each lane width is 131. On typical section D16 (Shannon Glen Court) the travelway is shown as 26' even though it consists of two 13' lanes and two 2' wide gutter pans. The dimensions shown on all the typical sections should be correct. According to Appendix B of the VDOT Road Design Manual, trees should be restricted from corners for distances of 30' in all directions in order to maintain sight distance. This recommendation is not being observed at a few intersections such as Shannon Glen Court & Towncenter Drive or Heathrow Glen Circle & Shannon Glen Drive. Except at corners, small trees may be planted within 3' of the back of curb on streets with design speeds of 20mph or less, or on streets with on- street parking. The following comments were provided in the June 19th, 2008 Site Review Committee Meeting: Sheet 7 - the entrance to Route 606 needs to have a layout as shown in The Minimum Standards of Entrances to State Highways with adequate tapers and curb offsets. Previous comments recommended a turn lane off Hollymead. The pavement width on Heathrow Glenn Circle should be reduced in area where there will be no on- street parking. The layout will cause a situation with parking in the driveways where the sidewalk will not and cannot be used because cars will be parked on the sidewalk. This should be reconfigured. The driveway entrances should be a CG -9D standard. Material Reports for the con -span should be submitted to VDOT ASAP to ensure adequate design. We have reviewed the drainage plans for this development and have the following comments: Underdrains (VDOT standard UD -4) are needed underneath the curb and gutter of roadway sections where the traffic volume is greater than or equal to 1000 vpd. Sag inlets E15, E14 -1 & 03 have longitudinal approach gutter slopes greater than 0.001 ft. /ft. Please have the engineer explain why slopes ranging from 0.016 to 0.072 were used. The pipe line from SDA3 to SDA2 has a slope greater than 16 %. This line needs to be flattened or install anchor blocks added at every other joint. The 96 "x48" arch pipe (con span) from SDJ2 to SDJ1 is under a private street and should not require the design conditions outlined in HDA 06 -02. If you have any questions, please contact Joel DeNunzio at (434) 293 -0011 ext. 120. Thanks, A.J. Hamidi, EIT Tech III Charlottesville Residency (434) 293 -0011