HomeMy WebLinkAboutSDP200700116 Review Comments Final Site Plan and Comps. 2008-10-08 (3)� OF AL vIRGINIP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: Hunters Hall Final Site Plan [SDP200700116] Plan preparer: Todd Philipp, Dominion Development Resources [tphilipp @ddrva.com] Owner or rep.: Virginia Land Company, Tucker Hurt [] Plan received date: 18 Aug 2008 Date of comments: 3 Oct 2008 Reviewer: Amy Pflaum, Current Development Engineering The Final Site Plan for Hunters Hall, submitted on 18 August 2008, has been reviewed. The plans cannot be approved as submitted and will require the following changes /corrections prior to final approval. Final Site Plan (SDP200700116) 1. The Tax Map Parcel Number is incorrect on the Title Sheet, it should be 49D. 2. This plan should be stamped & signed by a licensed professional. [18- 32.6.1] 3. Please provide a date of the topographic information: All topography should be at least visually field verified by the designer within the last year. [18- 32.6.6] 4. Please label all existing easements with deed book references. [ 18- 32.6.6] 5. Existing improvements are difficult to see on the plans, please adjust the shading and relocate any overlapping text. 6. It appears a guard rail is necessary around the proposed travelway in the south west corner. [18- 32.7.2] 7. New temporary construction and utility easements are shown in within the designated Tree Preservation Area. Will construction within these easements affect the tree preservation? 8. Is there an existing access easement over the access road, or does it have a private right -of -way? 9. The grading of the turn - around in the southern corner should be revised to crown the asphalt in order to direct flow to the two proposed filterras. The current proposed grading appears to direct flow directly into the sump inlet. 10. Please show sight distance triangles at the entrance. 11. Please show all existing and proposed easements, with labels and dimensions, on the site plan sheet. [18- 32.7.4] 12. Please provide a VDOT designation for the proposed curbing on the site plan. [18 -4.12] 13. If possible, please provide a sidewalk for access from the 4 proposed parking spaces in the front of the lot to the proposed building. 14. Please label the existing streets with route numbers, street names and pavement and right -of -way widths on the site plan sheet. [18- 32.6.6] 15. Please dimension and label the proposed stop -bar on the site plan. Drainage Profiles (SDP200700116) 16. Please provide profiles and stationing on the plan view of the proposed channels. 17. It is difficult to see the existing ground on the profiles, please adjust the shading. 18. Please show all utility crossings in the profiles, the proposed storm sewer crosses a proposed 6" waterline in the plan view. Albemarle County Community Development Engineering Review Comments Page 2 of 2 19. Please label all drainage structures with a VDOT designation in the profiles. 20. The proposed storm sewer is tying into an existing pipe that is at a 22% slope, does this existing pipe have anchors? Drainage Computations (SDP200700116) 21. Please remove the proposed improvements from the Pre - Developed Drainage Area sheet. 22. The proposed improvements significantly alter the drainage areas to the existing drainage structures. Please provide pre and post - development calculations using the SCS method for the 12" culvert under the entrance, the existing grate inlet in the southern corner of the lot and its 18" outfall pipe, ST -1 and its existing 18" outfall pipe, and the existing 30" culvert under Hunters Way. (Please see attached PDF' s) Water Protection Ordinance 23. A Water Protection Ordinance application including Erosion & Sediment Control and Stormwater Management plans must be submitted, reviewed, and approved prior to the approval of the Final Site Plan. 24. This submittal should include copies of manufacturer's approval of the plan for the filterras and the raintank. 25. Stormwater maintenance easements are necessary over the raintank and filterras and to provide for access to them. 26. A Stormwater Management Maintenance Agreement must be submitted to the County. 27. It appears that half of the proposed site is not being captured by stormwater treatment facilities. Please propose more filterra units or redirect flow to those already shown on the plans. Once these comments have been addressed, please submit 2 copies of the revised plans and reports to Current Development Engineering. Current Development Engineering is available from 2:30 -4 PM on Thursdays to discuss these review comments. Please contact Amy Pflaum at 434 - 296 -5832 ext. 3069 or email apflaum @albemarle.org to schedule an appointment. \ \Cob- dts01 \cityviewlnk\Docs \2007 Applications \2007 SDPs \SDP200700116 Hunters Hall\E3_fsp_ADP_07_116_Hunters Hall.doc