HomeMy WebLinkAboutSDP200700116 Review Comments Final Site Plan and Comps. 2008-10-08 (3)� OF AL
vIRGINIP
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4126
Project: Hunters Hall Final Site Plan [SDP200700116]
Plan preparer: Todd Philipp, Dominion Development Resources [tphilipp @ddrva.com]
Owner or rep.: Virginia Land Company, Tucker Hurt []
Plan received date: 18 Aug 2008
Date of comments: 3 Oct 2008
Reviewer: Amy Pflaum, Current Development Engineering
The Final Site Plan for Hunters Hall, submitted on 18 August 2008, has been reviewed. The plans cannot
be approved as submitted and will require the following changes /corrections prior to final approval.
Final Site Plan (SDP200700116)
1. The Tax Map Parcel Number is incorrect on the Title Sheet, it should be 49D.
2. This plan should be stamped & signed by a licensed professional. [18- 32.6.1]
3. Please provide a date of the topographic information: All topography should be at least visually field
verified by the designer within the last year. [18- 32.6.6]
4. Please label all existing easements with deed book references. [ 18- 32.6.6]
5. Existing improvements are difficult to see on the plans, please adjust the shading and relocate any
overlapping text.
6. It appears a guard rail is necessary around the proposed travelway in the south west corner. [18-
32.7.2]
7. New temporary construction and utility easements are shown in within the designated Tree
Preservation Area. Will construction within these easements affect the tree preservation?
8. Is there an existing access easement over the access road, or does it have a private right -of -way?
9. The grading of the turn - around in the southern corner should be revised to crown the asphalt in
order to direct flow to the two proposed filterras. The current proposed grading appears to direct
flow directly into the sump inlet.
10. Please show sight distance triangles at the entrance.
11. Please show all existing and proposed easements, with labels and dimensions, on the site plan sheet.
[18- 32.7.4]
12. Please provide a VDOT designation for the proposed curbing on the site plan. [18 -4.12]
13. If possible, please provide a sidewalk for access from the 4 proposed parking spaces in the front of
the lot to the proposed building.
14. Please label the existing streets with route numbers, street names and pavement and right -of -way
widths on the site plan sheet. [18- 32.6.6]
15. Please dimension and label the proposed stop -bar on the site plan.
Drainage Profiles (SDP200700116)
16. Please provide profiles and stationing on the plan view of the proposed channels.
17. It is difficult to see the existing ground on the profiles, please adjust the shading.
18. Please show all utility crossings in the profiles, the proposed storm sewer crosses a proposed 6"
waterline in the plan view.
Albemarle County Community Development
Engineering Review Comments
Page 2 of 2
19. Please label all drainage structures with a VDOT designation in the profiles.
20. The proposed storm sewer is tying into an existing pipe that is at a 22% slope, does this existing
pipe have anchors?
Drainage Computations (SDP200700116)
21. Please remove the proposed improvements from the Pre - Developed Drainage Area sheet.
22. The proposed improvements significantly alter the drainage areas to the existing drainage structures.
Please provide pre and post - development calculations using the SCS method for the 12" culvert
under the entrance, the existing grate inlet in the southern corner of the lot and its 18" outfall pipe,
ST -1 and its existing 18" outfall pipe, and the existing 30" culvert under Hunters Way. (Please see
attached PDF' s)
Water Protection Ordinance
23. A Water Protection Ordinance application including Erosion & Sediment Control and Stormwater
Management plans must be submitted, reviewed, and approved prior to the approval of the Final
Site Plan.
24. This submittal should include copies of manufacturer's approval of the plan for the filterras and the
raintank.
25. Stormwater maintenance easements are necessary over the raintank and filterras and to provide for
access to them.
26. A Stormwater Management Maintenance Agreement must be submitted to the County.
27. It appears that half of the proposed site is not being captured by stormwater treatment facilities.
Please propose more filterra units or redirect flow to those already shown on the plans.
Once these comments have been addressed, please submit 2 copies of the revised plans and reports to
Current Development Engineering.
Current Development Engineering is available from 2:30 -4 PM on Thursdays to discuss these review
comments. Please contact Amy Pflaum at 434 - 296 -5832 ext. 3069 or email apflaum @albemarle.org to
schedule an appointment.
\ \Cob- dts01 \cityviewlnk\Docs \2007 Applications \2007 SDPs \SDP200700116 Hunters Hall\E3_fsp_ADP_07_116_Hunters Hall.doc