HomeMy WebLinkAboutWPO200400044 Review Comments Stormwater Management Plan 2008-10-22ALg�,��
�'IRGINZ�
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4126
Project: WPO- 2004 - 00044, Old Trail Golf Clubhouse
Plan preparer: Collins Engineering, PE; Collins Engineering fax 434.245.0100
Email (scott @collins - engineering.com)
Owner or rep.: March Mountain Properties fax 434.245.0300
Date received: 19 September 2008
Date of Comment: 22 October 2008
Engineer: John P. Diez
The SWM for Old Trail Golf Clubhouse, received on 19 September 2008, have been reviewed. The plans
cannot be approved as submitted and will require the following corrections before approval can be granted:
A. Stormwater management plan:
1. Engineering review policy states that the riser crest stays within weir flow control during the 10yr.
storm. In this case, the head of the riser is acting as an orifice instead of a weir.
2. Drainage areas over 50 acres make use of more than one hydrologic method to verify computations
of peak flow.
3. Water quality calculations were not reviewed because contributions to the Licking Hole Basin
suffices for the clubhouse's water quality requirement. Future projects needing to use those facilities
will need to provide calculations at the time of submittal.
Once these comments have been addressed, please submit 2 copies of the revised plans,
calculations, and narratives to Current Development Engineering.
Current Development Engineering is available from 2:30 -4 PM on Thursdays to discuss these review
comments. Please contact John P. Diez at 434 - 296 -5832 ext. 3025 or email Odiez @albemarle.org) to
schedule an appointment.