Loading...
HomeMy WebLinkAboutSDP200800086 Review Comments Waiver, variation or substitution requirement 2008-06-23From: Glenn Brooks Sent: Monday, June 23, 2008 11:06 AM To: Francis MacCall; Judith Wiegand Cc: Amy Pflaum Subject: Willow Glen variation requests I have reviewed the list of 15 rezoning variation requests submitted with site plan (SDP200800086). I have only a few issues that need to be identified: 1. There is an issue regarding adequate turnaround on Trudeau Court. It appears this needs to be adjusted. 2. The removal of the small pond on the west side of Shannon Glen Court (Road D) appears problematic. This appears to leave this drainage area with a "bio - swale" instead. It does not appear that this is equivalent, as the swale will appear to have more maintenance and design issues. It appears difficult to get adequate bottom width, and it will have lot -to -lot maintenance, easement and drainage problems. This is expected to be an area for resident's storage, landscaping, decks, patios, etc. 3. The reduction in size of the primary stormwater pond must be evaluated in more detail with the final WPO plan. It is not clear that this is a given. 4. The proposed additional bio- detention pond appears redundant. It is close enough to units to have maintenance issues and this area drains to the larger pond anyway. This significantly reduces its value. Glenn Brooks, P.E. County Engineer Albemarle County