HomeMy WebLinkAboutSDP200800128 Review Comments Final Site Plan and Comps. 2008-10-31COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, Room 227
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832
October 31, 2008
BRW Architects
c/o Bruce Wardell
112 Fourth St NE
Charlottesville, VA 22902
RE: ARB2008 -00048 UVA Long Term Acute Care Hospital
Tax Map 59, Parcels 23B, 23131, 23C1, 23D and 23F
Dear Mr. Wardell:
Fax (434) 972 -4126
I have reviewed the revised ARB submittal for the above - referenced application, which included: architectural sheet
A4.1 with revision date of 9/25/08 and ARB submittal site drawing sheets L1.1 — L1.15 revised 9/25/08. 1 have the
following comments:
1. On the ARB plans, there are 4 existing Pine trees to remain located north of the Kirtley building. These trees do
not have any tree protection. Grading is proposed through some of these trees, such that it seems unlikely that
they would survive. Also, the Current Development plans don't show these trees as existing. Please correct and
clarify this.
2. There are 4 existing trees to remain in the island east of the LTACH service area. They have no tree protection.
Grading is shown through one of them, such that it seems unlikely that it would survive. Please correct and
clarify grading and add tree protection.
3. On the ARB plans, tree protection fencing is shown for some, but not all, of the existing trees to remain that are
located between the Kirtly parking area and the EC, and between the proposed LTACH building and the EC.
Please extend the tree protection fencing to protect all the trees to remain along the EC south of Kirtley and
LTACH.
4. 1 understand that the sewer issue at the north side of the site has been resolved and the existing trees in that
area will remain. Please update the plans accordingly.
5. The ARB lighting plans appear to include some inconsistencies: The OA fixture catalog number appears as
L5924 in the schedule and as L4554 on the cut sheet; colors are not indicated for the fixtures on the LTACH
site; the MWC and MWB fixtures have catalog numbers of 101 in the schedule and 102 on the cut sheets; the
OA1 fixtures on the west side of SIEG may be in an easement. Please correct, clarify, add and coordinate this
information.
6. The ELA (OA and OA1) light fixture is a traditional style fixture. Similar fixtures have previously had issues
meeting the full cutoff definition. In visiting the ELA website to confirm the full cutoff nature of the fixture, the
available information has confused the issue. Clicking on L4554 redirects the viewer to the L4554BH fixture.
That fixture is not identified as full cutoff. Furthermore, ELA specifically identifies some fixtures as "Dark Sky
Compliant ", which is not the same as full cut -off, and the L4554 fixture is not identified in this way. Revise the
OA and OA1 fixtures to emit less than 3000 lumens, or revise the fixtures to full cutoff fixtures, or obtain a
waiver from the Planning Commission for the proposed non -full- cutoff fixtures.
7. The ARB plans include the Moser site with its proposed landscaping; however, the Moser planting plan has
changed, so the LTACH /SIEG plan is no longer accurate in this regard. You may prefer to include a note on the
plan in the vicinity of the Moser site that references the Moser site plan for final landscaping, rather than
continuing to update the LTACH /Sieg plans with Moser revisions.
8. On the Sieg plan, the various sheets provide varying references to the material for the channel at the base of
the retaining wall /weir. The material for the channel is supposed to be field stone to match the walls — not
standard rip rap. All notes should be adjusted accordingly; please check all sheets. The ARB had asked for
planting in this area. I understand that Engineering will not allow this. I will mention this to the ARB and let you
know if there are further requirements.
9. A dumpster has been added to the Sieg site. Dumpster details appear in the ARB submittal on Sheet L1.15.
Detail B indicates that the gates will be stained dark gray. Detail A does not mention a stain for the enclosure
panel. Are only the gates to be stained? Detail D is also called " Dumpster Enclosure Gate" and is an aluminum
picket fence. This type of fence is an unusual choice for a dumpster. Where is this intended to be used? I will
mention the addition of the dumpster and the proposed finish of the enclosure to the ARB and I will let you
know if there are additional requirements.
10. A materials schedule was included on the architectural elevations as requested. The proposed bricks are listed
as: 1: Old Virginia 24 Colonial, 2: Old Virginia 183 Georgetown, and 3: Lawrenceville 023. The bricks previously
referenced were: 1: Old Virginia Flashed Virginia Rose, 2: Deep red brick, and 3: Dark red /black brick. Without
samples of the bricks that are listed in the current schedule, I can't confirm that they are the same as those
approved by the ARB. Please submit samples for confirmation. Also, the documentation on the actual glass
sample notes the color as "Harmony Graylite E- 159 ", not "E -158" as noted in the schedule. Please revise the
schedule to E -159. Finally, please note that the copy of the LTACH elevations does not clearly show the pattern
intended for the large brick panels on the south elevation. The drawings submitted with the building permit
application will need to clearly show that the pattern is the one that was approved by the ARB.
Please provide:
1. Two full sets of revised drawings addressing each of the bulleted comments listed above. Include updated ARB
revision dates on each drawing and an ARB approval signature panel.
2. A memo including detailed responses indicating how each condition has been satisfied. If changes other than
those requested have been made, identify those changes in the memo also. Highlighting the changes in the
drawing with "clouding" or by other means will facilitate review and approval.
3. The attached "Revised Application Submittal" form. This form must be returned with your revisions to ensure
proper tracking and distribution.
When staff's review of this information indicates that all conditions of approval have been met, a Certificate of
Appropriateness may be issued. If you have any questions, please do not hesitate to contact me.
Sincerely,
Margaret Maliszewski
Principal Planner
cc: Keith Whipple, McKee Carson, 301 East High Street, Charlottesville, VA 22902
UVA Facilities Planning & Capital Dev., PO BOX 800799, Charlottesville, VA 22908
University Of Virginia Health Services Found., 500 Ray C Hunt Dr., Charlottesville, VA 22903
Gerald Gatobu, Current Development
ARB File
�'JRGI1�1�
COUNTY OF ALBEMARLE
Department of Community Development
REVISED APPLICATION SUBMITTAL
This form must be returned with your revisions to ensure proper tracking and distribution. County staff has indicated below
what they think will be required as a resubmission of revisions. If you need to submit additional information please explain on
this form for the benefit of the intake staff. All plans must be collated and folded to fit into legal size files, in order to be
accepted for submittal.
TO: Margaret Maliszewski DATE:
PROJECT NAME: ARB2008 -00048 UVA Long Term Acute Care Hospital
Submittal Type Requiring Revisions ( ) indicates submittal Code
County Project Number
# Copies
Erosion & Sediment Control Plan (E &S)
# Copies
Distribute To:
Mitigation Plan (MP)
1
Margaret
Maliszewski
Waiver Request (WR)
Stormwater Management Plan (SWMP)
Road Plan (RP)
Private Road Request, with private /public comparison
(PRR)
Private Road Request — Development Area (PRR -DA)
Preliminary Site Plan (PSP)
Final Site Plan (or amendment) (FSP)
Final Plat (FP)
Preliminary Plat (PP)
Easement Plat (EP)
Boundary Adjustment Plat (BAP)
Rezoning Plan (REZ)
Special Use Permit Concept Plan (SP -CP)
Reduced Concept Plan (R -CP)
Proffers (P)
Bond Estimate Request (BER)
Draft Groundwater Management Plan (D -GWMP)
Final Groundwater Management Plan (F -GWMP)
Aquifer Testing Work Plan (ATWP)
Groundwater Assessment Report (GWAR)
Architectural Review Board (ARB)
ARB2008 -0048
Other: Please explain
(For staff use only)
Submittal Code
# Copies
Distribute To:
Submittal Code
# Copies
Distribute To:
ARB
1
Margaret
Maliszewski