HomeMy WebLinkAboutSDP200800125 Review Comments Final Site Plan and Comps. 2008-11-14Pavilions at Pantops Phase III SDP - 2008- 00125From: Denunzio, Joel D., P.E. [ Joel .Denunzio @VDOT.virginia.gov] Sent: Friday, November 14, 2008 2:00 PM To: Amy Pflaum Subject: Pavilions at Pantops Phase III SDP - 2008 -00125 Pavilions at Pantops Phase III SDP - 2008 -00125 Amy, I have reviewed the above plan and have the following comments: Roads are proposed to be private. VDOT review of roads is not necessary. The open cutting of Verona Dr. for the sanitary sewer should be avoided. When Verona Dr. is accepted for state maintenance, this cut will require a mill and overlay of the pavement for 100 feet wither side of the cut. The entrance dimensions and profile appear to meet the standards for a commercial entrance. ITE trip generation numbers need to be added to the plan Sight distance triangles must be shown at the entrance to Verona Dr. in accordance with the requirements in the Minimum Standards of Entrances to State Highways. Any sight lines that fall outside of the ROW on Verona must be within a sight distance easement. Clear zone easements must be set 8 feet behind the face of curb along the entire frontage of the property to ensure the lateral offset requirements in the VDOT Road Design Manual. If you have any questions, please let me know. Thanks, Joel Joel DeNunzio, P.E. Staff Engineer 434 - 293 -0011 Ext. 120 joel.denunzio @vdot.virginia.gov