HomeMy WebLinkAboutWPO200800098 Review Comments Road Plan and Comps. 2008-12-04WPO- 2008 -00098 Gillispie DevelopmentFrom: Denunzio, Joel D., P.E. [ Joel .Denunzio @VDOT.virginia.gov] Sent: Thursday, December 04, 2008 2:54 PM To: Patrick Lawrence Cc: Amy Pflaum Subject: WPO- 2008 -00098 Gillispie Development Pat, I have reviewed the above plan and have the following comments: Comments provided on Dec. 28, 2007 under SUB - 2007 -00286 have not been addressed. Any sight distance lines that fall outside of the ROW or prescriptive easement need to be within a sight distance easement. The culvert under the proposed road is shown on the plan as 15 inches and calculated as 12 inches. The minimum diameter should be 15 inches. The minimum cover on the pipe needs to be 2 feet in accordance with VDOT PC -1 standard. The design headwater elevation needs to be 18 inches below the shoulder as shown in Chapter 8 of the VDOT Drainage Manual. Please let me know if you have any questions. Thanks, Joel Joel DeNunzio, P.E. Staff Engineer 434 - 293 -0011 Ext. 120 joel.denunzio @vdot.virginia.gov