Loading...
HomeMy WebLinkAboutSDP200600125 Review Comments Appeal to BOS 2009-01-23ALBEMARLE COUNTY PLANNING STAFF REPORT SUMMARY Project Name: SDP2006 -125 Vandine Plaza Staff: Amy Pflaum, Engineer Preliminary — Entrance Requirement Waiver Planning Commission Public Hearing: Board of Supervisors Hearing: February 3, 2009 Not applicable Owners: AUTO, LLC Applicant: Justin Shimp, Dominion Development Resources Acreage: 2.52 acres Rezone from: Not applicable Special Use Permit for: Not applicable TMP: Tax Map 45, Parcels 100, 101, and 101 B By -right use: C -1 (Commercial) Location: Located on W. Rio Road [Rte. # 631 ] approximately 0.1 miles southeast of its intersection with Berkmar Drive [Rte. #1403]. Magisterial District: Rio Proffers /Conditions: No Requested # of Dwelling Lots: N/A DA — X RA— Proposal: Request a waiver from the requirements Comp. Plan Designation: Regional Service of Section 4.12.17.b "Entrances to parking areas in Urban Area 1 from public streets" of the Zoning Ordinance Character of Property: Undeveloped area Use of Surrounding Properties: adjacent to commercial and single - family Commercial and single - family residential (R6). development. Factors Unfavorable: Factors Favorable: 0 Design measures do not satisfy the technical requirements of the ordinance. None. • A possible alternative has not been explored. RECOMMENDATION: Denial STAFF PERSON: Amy Pflaum, Engineer PLANNING COMMISSION: February 3, 2009 AGENDA TITLE: SDP2006 -125 Vandine Plaza Preliminary - Entrance Requirement Waiver APPLICANT: Justin Shimp, Dominion Development Resources PROPERTY OWNER(S): Auto, LLC APPLICANT'S PROPOSAL: Per County Code Section 18- 4.12.2.d, the applicant is requesting a Planning Commission review of the denial of the administrative waiver request. The applicant has requested a waiver for relief from providing an adequate entrance landing as required per County Code Section 18.4.12.17.b. This section requires that an adequate landing and/or grade transition shall be provided for vehicle access aisles at the intersection with public streets to allow for stopping of vehicles and sight distance. The approach grade should not exceed 4% for a distance of not less than 40 feet from the edge of the street being intersected. The existing access does not meet the requirements of the Code. The first 40 feet from the edge of Rio Road West slopes downward at up to 15%. COMPREHENSIVE PLAN: The Comprehensive Plan designates this property as Regional Service in Urban Area 1. REASON FOR PLANNING COMMISSION REVIEW: Per County Code Section 18- 4.12.2.d, the applicant is requesting a Planning Commission review of the denial of the administrative waiver request which was made to waive the requirements of Section 18- 4.12.17.b Entrances to parking areas from public streets. PLANNING AND ZONING HISTORY: On December 11, 2006, an application was filed for preliminary site plan approval for construction of two retail buildings totaling 26,866 square feet on 2.52 acres zoned C -1 (Commercial) and EC (Entrance Corridor). Staff comments required the applicant to explore the ability to upgrade the existing shared entrance that served this property and the neighboring commercial property (TMP 45 -102). The existing entrance does not meet the technical criteria of Section 18- 4.12.17.b for entrances to parking areas from public streets, particularly the requirement of an adequate landing — a grade no more than four (4) percent for a distance of not less than forty (40) feet measured from the edge of the street or road being intersected. On April 29, 2008 the applicant asked for a waiver of the requirements of Section 18- 4.12.17.b. Staff administratively reviewed the waiver (please see attached memo from Amy Pflaum to Bill Fritz, dated May 30, 2008) and it was denied. On December 3, 2008 the applicant submitted a letter from the owner of Photoworks (existing retail shop on TMP 45 -102) stating his preference that no reconstruction of the existing entrance takes place. The applicant also submitted a letter from VDOT stating that only one shared entrance will be allowed 2 to serve Photoworks and the proposed Vandine Plaza property. Based on these two limitations, the applicant is stating that no alternatives exist other than allowing Vandine Plaza to be served by the existing sub - standard entrance. DISCUSSION: The County has previously suggested to the applicant that a new shared entrance could be constructed within the Vandine Plaza site to serve the new development and Photoworks. This entrance could be constructed to meet the standards of the Ordinance. During construction, the sub - standard entrance to Photoworks could remain opened and undisturbed. Once construction of the new entrance is complete, the sub - standard entrance could be closed. This presents a safer alternative, not only for the future traffic anticipated at the Vandine Plaza site, but also the construction traffic that will be entering and exiting the site while it is being built. The Photoworks owner is not amenable to reconstruction of the existing entrance, but has not presented an opinion regarding a new shared entrance. VDOT has stated that the entrance may be relocated, as long as only one entrance remains to serve both properties. The applicant has not demonstrated that the option to provide a new shared entrance for both sites is unattainable. SUMMARY AND RECOMMENDATION: Staff review has resulted in unfavorable findings: Unfavorable factors: 1. The existing condition does not satisfy the technical requirements of the ordinance and it therefore presents a safety concern. 2. The alternative of designing and constructing a new shared entrance that meets the requirements of the ordinance has not been explored by the applicant. Staff recommends denial of this waiver. ATTACHMENTS: A. Site Plan B. Location/Detail Maps C. Applicant Justification D. Staff comments on waiver request: E1_wvr_ADP_Vandine Plaza.doc