Loading...
HomeMy WebLinkAboutWPO200900010 Review Comments Erosion Control Plan 2009-03-24ALg�,�� �'IRGINZ� COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: WPO- 2009 - 00010, Meadow Creek Sanitary Sewer Interceptor ESC plans Plan preparer: William Judy; Greeley and Hansen Owner or rep.: Michelle Simpson; Rivanna Water and Sewer Authority Date received: 19 February 2009 Date of Comment: 24 March 2009 Engineer: Phil Custer The ESC plans for the upgrade to the Meadow Creek Sanitary Sewer Interceptor, received on 19 February 2009, have been reviewed. The plans cannot be approved as submitted and will require the following changes /corrections prior to final approval. A. General review comments: 1. This review is only for the portion of the ESC plan within the County. ESC measures within the city limits must be reviewed and approved by the city. 2. The aerials over the streams are regulated by 18 -30.3 Flood Hazard Overlay District Section of the Zoning Ordinance and require a special use permit to be approved by the County Board of Supervisors (please see the determination from the Zoning Department). A letter of map amendment through FEMA will likely be a condition of approval. [18 -30.3] (link to application) 3. Please provide proof of permanent and temporary easements from the owners of all county parcels affected by construction operations. If permanent easements already exist, please provide the deedbook and page number in the plan view sheets. If new permanent easements are needed, please provide the necessary plats. Temporary construction easements can be an email or letter from the property owner stating the proposed work outside of the permanent utility easement is allowed on his/her parcel. 4. Please provide the FEMA map number and date for the floodplain. 5. The FEMA floodplain should be shown at the elevations specified in the latest map. 6. Please provide the source, date, and benchmark of the topography. 7. Please provide approval from the Army Corps of Engineers for the proposed work within the streams and wetlands. 8. VDOT approval is required. At this time, VDOT comments have not yet been received. B. ESC review comments: 1. All construction entrances must be shown as 12ft by 70ft in the plan. 2. Please provide a note on sheet C5 at the City /County line that construction access to the interceptor from Sta. 64 +50 to 72 +50 is from Holmes Ave. and was reviewed and approved by the City of Charlottesville. There are two stream crossings (SC) proposed on sheet C6. Please specify the design of each of these crossings. It appears that due to the size and characteristics of both drainage areas, a temporary bridge will be required for each. The stream crossings should be located outside of the area needed to construct the sewer lines. Engineering review recommends accessing this area of the project from the west through TMP 61 -192 because a prolonged construction entrance at that section of Rio Road may be problematic. 4. Please provide dewatering structure symbols at the other two utility stream crossings. 5. Please show the existing vegetation, existing tree lines, and proposed treelines on the plan. [DM] 6. Please provide a staging and parking area on the plan. 7. On sheet G1, please add a note to the Barrier Tape designator (BT) and linestyle that it is to double as the limits of construction line. 8. Please provide a stream crossing at Sta. 93 +00. Please provide the design of this stream crossing. What will the permanent solution for the sewer crossing of this stream be since the pipe appears to be obstructing the existing stream flow? 9. Please end the limits of construction line at the end of Contract A. 10. The ESC bond will be computed once all comments have been addressed. Please contact me at 434 - 296 -5832 ext. 3072 or email pcuster @albemarle.org if you have any questions. File: El_esc_PBC_WP02009 -00010 Meadowcreek Interceptor.doc