Loading...
HomeMy WebLinkAboutSDP200800179 Review Comments Final Site Plan and Comps. 2009-05-08� OF AL ,. vIRGI1`IZP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: Plan preparer: Owner /Applicant: Plan received date: Rev 1: Date of comments: Rev 1: Reviewer: A. Final Site Plan Three Notch'd Center [SDP200800179] NP Engineering [email: nat.perkins@,gmail.co LLC [email: Unknown] 16 December 2008 10 March 2009 26 January 2009 8 May 2009 John P. Diez — Engineering Technician 1. Please provide date of topography. [18- 32.6.6, 14 -302, Policy for date] (Rev.]) Comment has been addressed. 2. Please state the location of the benchmark on the coversheet. (Rev.]) Comment has been addressed. 3. Please provide all existing easements (access, drainage, sight, sanitary easements, etc.) with deed book references, locations, and dimensions. [18- 32.6.6, 14 -302] (Rev.]) Comment has been addressed. 4. Please provide a legend showing all symbols and abbreviations used on the plans. (Rev.]) Comment has been addressed. 5. Please provide a VDOT designation (PE -1, CG -9a, etc) to all entrances. (Rev.]) Comment has been addressed. 6. Please provide proposed topography on the entrance of the west side of the lot. The entrance cannot exceed 4% grade for a distance of 40' from the intersected street, measured anywhere in the entrance. [18- 4.12.17] (Rev.]) Comment has not been addressed. Parts of the plan appear to have both l' and 2' contours. Please clarify and make contour numbers more legible. 7. Please provide sight distance lines at the entrances, less than . 0 x speed limit intersected streets, measured from a point 10' off the edge of pavement of the intersected street. (Rev.]) Comment has been addressed. 8. VDOT approval must be maintained for any plan affecting right -of -way. (Rev.]) Comment has not been addressed 9. The proposed loading space should be adjacent to the structure and needs to have minimum dimensions of 12'x25' [18- 4.12 -13] (Rev.]) Comment has been addressed. 10. Please label the hatched area by Three Notch' d Road on sheet 5. (Rev.]) Comment has been addressed. 11. Sidewalks abutting parking must be 6' wide, or bumper blocks must be provided. Please refer to the Design Standards Manual. (Rev.]) Comment has been addressed. 12. Please provide arrows indicating direction of flow for all existing and proposed storm sewers. (Rev.]) Comment has been addressed. Albemarle County Community Development Engineering Review Comments Page 2 of 2 13. Please provide throat length for each drop inlet. (RevJ) Comment has not been addressed. The throat length for Structure #3 seems to be out of scale. It seems that a 14' throat length would overlap with the filterra facility and the light post. Please revise. 14. Please clarify if STR -6 is a manhole or an inlet. (RevJ) Comment has been addressed. 15. Please provide an end section for the outlet to the stormwater detention facility. (Rev.]) Comment has been addressed. B. Stormwater Management Plan 16. Please submit Stormwater Management plans with details and calculations. Please refer to the Virginia Stormwater Management Handbook. (Rev 1) Comment has been addressed. 17. The storm sewer pipes from Structure #3 through Structure #1 do not match with those of the storm sewer profile. 18. Please provide proposed pipe and inlet drainage map showing watershed limits, acreage, hydrologic coefficient, time of concentration, and destination structure for each drainage area. 19. Please provide general stormwater notes. Please refer to the Design Standards Manual. 20. Please provide a larger scale of the post - development drainage area. C. Erosion and Sediment Control Plan 21. Please submit Erosion and Sediment Control plans with details. Please refer to the Virginia Erosion and Sediment Control Handbook. (Rev. 1) Comment has been addressed. 22. Please provide erosion and sediment control notes. Please refer to the Design Standards Manual.