Loading...
HomeMy WebLinkAboutSDP200900034 Review Comments Major Amendment, Final Site Plan 2009-05-08*—&A County of Albemarle Department of Community Development Memorandum From: Max Greene, Current Development engineering review Date: 7 May 2009 Subject: Martha Jefferson Outpatient Care Center (SDP200900034) The preliminary site plan has received Engineering review. The following comments are to address the Engineering concerns with the plan. The following items will be adequately addressed prior to preliminary approval: 1. Please submit a SWM Modified Simple Method worksheet for review. 2. SWM Plan should be clarified to show the currently existing site conditions and the proposed changes to impervious areas. All previous site conditions are superfluous to the approval process. ( Stormwater protection cannot be grandfathered.) 3. Please clarify the location of loading spaces as required. [18- 4.12.13] The following items will be adequately addressed prior to final site plan approval: 4. VDOT approval is required for the proposed impacts to public travelways. 5. Unobstructed sight distance lines at entrances, less than 10' x Speed Limit of intersected streets, measured from a point 10' off the edge of pavement of the intersected street. 6. E &SC and SWM protection plans and fees are required for review. [17 -302, 17 -303] The Proposed E &SC plan does not appear to work as shown and will require modification to reduce the burden on the contractor. This office suggests a meeting to discuss engineering concerns. Current Development Engineering is available from 2:30 -4 PM on Thursdays to discuss these review comments. Please contact Max Greene at 434 - 296 -5832 ext. 3283 or email =reene @albemarle.org to schedule a Thursday afternoon appointment. 7. Paved construction entrance will be required. This office recommends utilizing the existing pavement for the construction entrance. 8. Dumpster pad detail or specification to be a minimum 4" stone base and 6" concrete of 3000psi at 28 days, or stronger, reinforced with a minimum grid of wire reinforcing or #4 bars at 12" on center. [Specs are policy] 9. Proposed slopes steeper than 3:1 will have low maintenance (not grass) ground cover specified on the plan. [Policy] 10. Drainage profiles and matching drainage computations required. [14 -311, 18 -32] 11. Please supply copies of manufacturer's approval of the plan for any manufactured stormwater management facilities (filterra, stormfilter, sandfilter, etc.) [Policy] 12. A completed copy of the Standard Stormwater Maintenance Agreement and fee for recordation for the stormwater facilities is required prior to final approval. [17 -304E] The forms and instructions can be found on the Community Development Department Web site on www.albemarle.org . 13. Albemarle Design Standards Manual contains a checklist with additional requirements for Final site plan approval. file: El_psp_MRG_Martha Jefferson Outpatient Care Center (Proffit Rd.).doc