Loading...
HomeMy WebLinkAboutSDP200900034 Review Comments No Submittal Type Selected 2009-05-18�'IRGINZP COUNTY OF ALBEMARLE Department of Community, Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 DATE: May 12`x', 2009 Rachel McKinney [RK &K] 801 E Main Street Richmond, VA, 23219. RE: SDP - 2009 -00034 Martha Jefferson Outpatient Care-Center Dear Madam, The Site Review Committee has reviewed the development proposal referenced above. Preliminary comments for the following divisions of the Department of Community Development and other agencies, as applicable, are attached: Albemarle County Division of Zoning & Current Development (Planner) Albemarle County Division of Zoning & Current Development (Engineer) Albemarle County Division .of Planning (ARB Planner) Albemarle County Division of Planning (Development Area Planner) Albemarle County Division of Inspections (Building Official) Virginia Department of Transportation (VDOT). Albemarle County Service Authority (ACSA). Albemarle County Geographic and Data Services (GDS) Albemarle County Fire and Rescue Comments reflect information available at the time the development proposal was reviewed, and should not be considered final. However, the Site Review Committee has attempted to identify all issues that could affect approval of the proposed project. Please make the revisions that have been identified as necessary for preliminary approval by the Site Review Committee. If you choose not to make the requested revisions, please submit in writing justification for not incorporating such revisions. Submit eight (8) full size copies and one (1) 11" x 17" copy to the Department of Community Development including responses to each of the attached comments of the Site Review Committee by Monday, June 1", '2009. Failure to submit this information by this date will result in suspension of the review schedule. Review will resume when revisions are submitted along with a reinstatement fee of $65. Please contact me at your earliest convenience if you have questions or require additional information. Gerald Gatobu, Principal Planner County of Albemarle Department of Community Development Current Development 401 McIntire Road Charlottesville, VA 22902 -4596 Phone: (434)296 -5832 Ext 3385 Fax: (434)972 -4126 U �ulu �'rRGLNZP County of Albemarle Department of Community Development Memorandum To: Rachel McKinney (RK &K) From: Gerald Gatobu, Principal Planner Division: Zoning and Current Development Date: May 18, 2009 Subject: SDP2009 -00034 Martha Jefferson Outpatient Care Center Major/Preliminary Site Plan The County of Albemarle Division of Zoning and Current Development will grant or recommend approval of the major /preliminary site plan referred to above once the following comments have been addressed: [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] ❑ 32.5.6 The preliminary site plan shall contain the following information: ❑ a. The name of the development: Include the site plan number SDP2009 -00034 to the site plan for current and future reference. ❑ c. If phasing is planned, phase lines and proposed timing of development. Required parking will have to be available for the existing use at all times, therefore, the plan will have to be carefully phased to manage parking for the existing use and parking for the proposed addition. ❑ 1. Location of other existing and proposed utilities and utility easements. Are there any proposed utility easements with the new addition? ❑ n. Location and dimensions of all existing and proposed improvements including: Outdoor lighting: A lighting plan'that complies with the lighting requirements of section 4.17 of the Albemarle County Code will be required at final site plan stage if outdoor lighting is proposed. Loading and service areas together with the proposed paving material types for all walks, parking lots and driveways; Loading spaces shall be provided in addition to and exclusive of any parking requirement on the basis of (1) space for the first eight-thousand (8,000) square-feet of office space plus one (1) space for each additional twenty thousand (20,000) square feet of office space. Please show the location and the required number of loading spaces for the use. Signs: New /proposed signs for the facility should not be shown on this site plan. Signs are approved during sign permit application review. The location of any proposed signs will be approved during sign permit review. � IHGIt��P County of Albemarle Department of Community Development Memorandum From: Max Greene, Current Development engineering review Date: 7 May 2009 Subject: Martha Jefferson Outpatient Care Center (SDP200900034) The preliminary site plan has received Engineering review. The following comments are to address the Engineering concerns with the plan. The following items will be adequately addressed prior to preliminary approval: -1. Please submit a SWM Modified Simple Method worksheet for review. 2. SWM Plan should be clarified to show the currently existing site conditions and the proposed changes to impervious areas. All previous site conditions are superfluous to the approval process. ( Stormwater protection cannot be grandfathered.) 3. Please clarify the location of loading spaces as required. [18- 4.12.13] The following items will be adequately addressed prior to final site plan approval: 4. VDOT approval is required for the proposed impacts to public travelways. 5. Unobstructed sight distance lines at entrances, less than 10' x Speed Limit of intersected streets, measured from a point 10' off the edge of pavement of the intersected street. 6. E &SC and SWM protection plans and fees are required for review. [17-302,17-303] The Proposed E &SC plan does not appear to work as shown and will require modification to reduce the burden on the contractor. This office suggests a meeting to discuss engineering concerns. Current Development Engineering is available from 2:30 -4 PM on Thursdays to discuss these review comments. Please contact Max Greene at 434 - 296 -5832 ext. 3283 or email m eene ,albemarle.org to schedule a Thursday afternoon appointment. 7. Paved construction entrance will be required. This office recommends utilizing the existing pavement for the construction entrance. 8. Dumpster pad detail or specification to be a minimum 4" stone base and 6" concrete of 3000psi at 28 days, or stronger, reinforced with a minimum grid of wire reinforcing or #4 bars at 12" on center. [Specs are policy] 9. Proposed slopes steeper than 3:1 will have low maintenance (not grass) ground cover specified on the plan. [Policy] 10. Drainage profiles and matching drainage computations required. [14 -311, 18 -32] 11. Please supply copies of manufacturer's approval of the plan for any manufactured stormwater management facilities (filterra, stormfilter, sandfilter, etc.) [Policy] 12. A completed copy of the Standard Stormwater Maintenance Agreement and fee for recordation for the stormwater facilities is required prior to final approval. [17 -304E] The forms and instructions can be found on the Community Development Department Web site on www.albemarle.ora . 13. Albemarle Design Standards Manual contains a checklist with additional requirements for Final site plan approval. sJkl: '.:. .. >J�E: ^: i.t.3.... e'X15' €:: %:.;: ::I' >:li.:E. ?ilipai.(i-vCan: (P ReM.kk Si: Albemarle County Service Serving '4 Conserving. TO: Gerald Gatobu FROM: Gary Whelan, Civil Engineer DATE: `May 11, 2009 RE: Site Plan Technical Review for: Martha Jefferson Outpatient Care Center (Proffitt) SDP2000900034 TM32A 2 =1 A The below checked items apply to this site. X 1. This site plan is within the Authority's jurisdictional area for: X A. Water and sewer B. Water only C. Water only to existing structure D. Limited service X 2. An 8 inch water line is located on site. 3. Fire flow from, nearest public hydrant, located distant from this site plan, is Gpm + at 20 psi residual. X 4. An 8 inch sewer line is located on site. 5. An Industrial Waste Ordinance survey form must be completed. X 6. No improvements or obstructions shall be placed within existing or future easements. 7. and plans are currently under review. 8. and plans have been received and approved._ X 9. No plans are required. -10. Final and plans are required for our review and approval prior to granting tentative approval. 11. Final site plan may /may not be signed. 12. RWSA approval for water and /or sewer connections. '13. City of Charlottesville approval for sewer. Comments: Backflow prevention is required. Provide a plumbing fixture count to size the meter. The site plan does not show or incorrectly shows: meter locations water line size waterline locations sewer line size sewer line locations expected wastewater flows easements expected water demands 168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 - Fax (434) 979 -0698 www.serviceauthoriy.org �II0III COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 April 24, 2009 Scott J Swanson AIA Gresham, Smith and Partners 10 South Sixth St. Suite '100 Richmond VA 23219 RE: ARB2009 =00018 Martha Jefferson Hospital — 29 North /Proffit Additions Tax Map 32A, Section 2 Parcel 1A Dear Mr. Swanson: The Albemarle County Architectural Review Board, at its meeting on April 20, 2009, completed a preliminary review of the above -noted request to renovate an existing building, construct an addition to the building, and expand required site improvements including parking. The Board offered the following comments for the benefit of the applicant's next submittal. Please note that the following comments are those that have been identified atthis time. Additional comments may be added or eliminated based on further review and changes to the plan. 1. Revise Sheet A.301 Elevationsto include a schedule listing all proposed materials and colors. The schedule should include the manufacturer's name, product ID, and color for all proposed materials. Revise the building elevations to clearly indicate the location of each material. Revise the design of the southeast porte- cochere to either more effectively integrate with the architecture of the building or identify itself as a pavilion -like element. Revise all applicable drawings to clearly indicate the proposed materials and colors. 2. Revise Sheet A.301 Elevations to include a dashed outline delineating the height and location of the rooftop equipment. Dimension the drawing to show the distance from the top of the equipment to the top of the screen. Add a note to Sheet A.301 Elevations and Sheet 2 of 3 Layout & Utility Plan stating: All rooftop equipment shall not be visible from the Route 29N Entrance Corridor. 3. Revise Sheet LL -1 Landscape Plan to include details of all plant materials proposed for the bio- filter adjacent to the southwest boundary. A planting design that disguises the utilitarian purpose of this facility would be appropriate. 4. Revise the Existing Conditions Plan, Layout & Utility Plan and Grading & Drainage Plan to show the location, species, and size of all existing trees and shrubs. Delineate the plantings that are to remain and those that are to be removed. Provide an Erosion and Sediment Control Plan delineating the limits of grading and clearing and the location and method of tree protection. Revise the Landscape Plan by showing all existing planting that is to remain, identified for species and size. 5. Revise all applicable drawings by reducing the number of parking spaces by 3 for a total of 198 spaces. Achieve this reduction by converting 3 equidistant parking spaces, currently shown along the perimeter of the western most parking lot, facing Route 29, to 3 individual planting islands with large canopy trees. 6. Revise Sheet LL -1 Landscape Plan to show a total of 8 London Plane trees, 35' on center, along the Route 29N frontage. 7. Revise Sheet LL -1 Landscape Plan to show a total of 4 Crimson King Red Maple trees, .2 1/2' in caliper, 40' on center, along the perimeter of the parking lot adjacent to the Proffit Road right -of -way. Revise the drawing to show trees, 40' on center, 21/2" in caliper, along the edge of the curvilinear parking proposed in the southwest corner of the site. 8. Revise Sheet LL -1 Landscape Plan to show the following: • The location of the existing overhead power line /easement along the Route 29N frontage. The proposed underground stormwater management system. The proposed sanitary sewer connection west of the addition. • The proposed underground fire (water) line east of the addition. The proposed grading as shown on Sheet 3 of 3 Grading & Drainage Plan. The location of all proposed site lighting. If site lighting is not proposed, add a note on the drawing to that effect. 9. Revise the location and /or type of street trees along the Route 29N Corridor to avoid conflicts with overhead utilities. Revise Sheet LL -1 Landscape Plan to include the following note: All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height, the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant. 10. Revise Sheet LL -1 Landscape Plan by replacing the linear planting of Compacta Hollies, shown along the perimeter of the existing /proposed parking lot west of the existing /proposed buildings, with a wider planting area whose outer (EC) edge parallels the Route 29N Corridor. Provide plant material within this planting area that includes a mix of shrub types and heights (4 species minimum), arranged in a less structured, natural layout. 11. Revise Sheet LL -1 Landscape Plan by showing a mix of shrub species, with varying heights, around the foundation of the proposed addition. Revise the planting proposal in the area formed by the south elevation of the existing structure, the west elevation of the proposed addition, and the adjacent curvilinear parking with a proposal that includes more planting, with a mix of plant types and species that will serve, as viewed from the Corridor, as a visual transition between the existing and proposed buildings. 12. For all proposed signage, provide a complete sign package addressing all of the criteria outlined in the ARB Sign Review Checklist. Reduce the size of the EMERGENCY sign, proposed directly beneath the cornice in the southwest corner of the proposed structure, so as not to crowd the sign area, and revise the location to one that is more coordinated with the architecture. Revise Sheet LL -1 Landscape Plan to include a landscape proposal for the area around the freestanding signs. This proposal should serve to incorporate the sign into the overall planting plan for the development. 13. Provide a lighting photometric plan showing the location of all proposed site, building and decorative lighting. Include a luminaire schedule of all proposed exterior lighting on the photometric plan, clearly indicating all lighting options chosen, including but not limited to heights and colors proposed for all fixtures and poles. All fixtures emitting 3,000 or more lumens shall be full cutoff style fixtures. If site lighting is not proposed, revise Sheet 2 of 3 Layout & Utility Plan to include a note to that effect. 14. Revise the Plant Schedule on Sheet LL -2 Landscape Plan to correctly identify the plant label for the Nellie Stevens Holly as NH. 15. Create a transition between the new construction and the existing construction to prevent juxtaposition of new and old materials. 16. Reconsider the replication of the bay window element by including otherforms that reflect the architectural character in differing ways. 17. Revise Sheet A.301 Elevations by: • Correctly identifying the drawing scale as 1" = 8'. • Correctly identifying elevation East Exterior Elevation as the West Elevation and elevation North Exterior Elevation'as the South Elevation. • Correctly identifying existing and new construction. • Revising all annotation referring to refurbishing existing EIFS to correctly reflect the applicant's intention of replacing it with the EIFS sample included in this submission. You may submit your application for continued ARB review at your earliest convenience. Application forms, checklists and schedules are available on -line at www.albemarle.ora /planning. Revised drawings addressing the comments listed above are required. Include updated ARB revision dates on each drawing and an ARB approval signature panel. Please provide a memo including detailed responses indicating how each comment has been addressed. If changes other than those requested have been made, identify those changes in the memo also. Highlighting the changes in the drawing with "clouding" or by other means will facilitate review and approval. If you have any questions concerning any of the above, please feel free to call me. Sincerely, Brent Nelson Landscape Planner cc: Ron Cottrell Martha Jefferson Hospital 459 Locust Ave Charlottesville, VA 22902 Application :* SDP200900034 si ort Review 'Comments Project Name: Martha Jefferson Outpatient Care Center (Proffitt) -Major Major Amendment Date Completed: Reviewer: Review Status: Reviews Comments: Date Completed: Reviewer: Review Status: Reviews Comments: Date Completed: Reviewer: Review Status: Reviews Comments: Date Completed: Reviewer: Review Status: Reviews Comments: 05/12/2009 Andrew Slack E911 No Objection NO OBJECTION. 05/04/2009 James Barber Fire Rescue Requested Changes Please indicate the location of fire hydrants. All portions of the building must be within 400 feet of a hydrant by way of a prepared travel way. Please indicate the fire flow from existing hydarnts and estimated fire flow (calculations) for proposed hydrants. Judith Wiegand Planning Requested Changes Long -range plannign staff has reviewed this preliminary site plan for compliance with the Comprehensive Plan, including the Neighborhood Model. The proposed use is in compliance with the Comprehensive Plan. Staff has identified the following issues and recommends the following changes: 1. Sidewalks should be shown along both Proffit Road and Leake Square. 2. The applicant should be aware that Proffit Road will be widened to a four -lane section from the intersection with US 29 west to well beyond Worth Xing / Leake Square. A roundabout will also be constructed at the intersection of Proffit/Leake/Worth Crossing. The applicant should consult with VDOT to make sure they have left enough right -of -way along Proffit Road, especially at the corner where the roundabout is proposed. 3. Also, Leake Square will become a public road and be extended as a part of the North Pointe development. The applicant should be certain they have left enough right -of -way along Leake Square for the road to be constructed to public standards. 4. Both of these road improvements may have an impact on the amount and location of parking shown on the site plan. 05/08/2009 Max Greene CommDev- Current Development Requested Changes SRC 5/21 Page: 1.00 County of Albemarle Printed On: Monday, May 18, 2009