Loading...
HomeMy WebLinkAboutWPO200600030 Review Comments Erosion Control Plan 2009-07-10� OF AL vIRGINIP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: SUB - 2006 - 00124, WPO- 2006 - 00030, East Ingleridge Farm Subdivision, Public Road, E &SC & SWM Plans Plan preparer: Dominion Development (fax 434 - 984 -8863) Owner or rep.: Ingleridge Farm LLC (fax 434 - 296 -3510) Plan received date: 12 June 2009 Date of comments: 14 July 2009 Reviewer: Max Greene The road, ESC and SWM plans for East Ingleridge Farm Subdivision received on 12 June 2009, have been reviewed. The plans will require the following changes /corrections prior to final approval. A site visit conducted on 7 July 2009 has determined the plans are not consistent and do not appear to match the existing site conditions. The existing road and structures are not depicted on some of the plans. Several "layers" appear to be on some pages and off on others. Complete review is not possible due to condition of submittal. Additional comments will be forthcoming upon complete and congruent submittal. A. Road and drainage plans (SUB- 2006 - 00124, original file SUB - 2005- 00061) 1. DOT approval is required. 2. VDOT street designation sign appears to be missing from the entrance area. 3. Speed limit signage appears missing. 4. EC -1's and ES -1's are required for culvert inlets. 5. Entrance culvert pipe inlet sump area will be designed for the drainage area. B. Stormwater Management and Mitigation Plan (WPO- 2006 - 00030) 1. A mitigation plan and fee will be submitted to the County. Mitigation plan can be attached to the SWM plan. [Policy] 2. Plan appears to require two bio- filters on the South and west side of the stream crossing near road station 15 +00. 3. Please extend the emergency spillway for Bio- filters 5 & 6 down the back slope of the embankment to the existing channel or a stabilized area below the outlet pipe. [DM] 4. Please label or remove what appears to be a wall in bio - filters 7 & 8. 5. Bio - filter 6 does not appear complete. 6. Please increase the 3' riser to 4' for the 24" barrel pipe connection. 7. Mitigation areas will be adjusted to exclude the SWM outfalls. 8. A completed copy of the Standard Stormwater Maintenance Agreement and fee for recordation for the stormwater facilities is required prior to final approval. [17 -304E] The forms and instructions can be found on the Community Development Department Web site on www.albemarle.org. Albemarle County Community Development Engineering Review Comments Sheet 2 of 2 C. Erosion Control Plan (WPO- 2006 - 00030) 1. Please update the E &SC narrative to current design standard requirements. [I.E. Temporary Paved construction entrance, E &SC Notes, ] 2. Culvert `B" does not appear to have adequate protection from sediment loss until after the fill operation is completed. Please refer to County Engineer comment #5 for stream crossings. http : / /www.albemarle.org/department .asp ?department= plannin &relpa ,-e =11705 3. This office recommends utilization of SWM basin #1 for E &SC control instead of constructing several different structures for the same drainage area. Please provide the additional information when the revised plans are submitted. Engineering is available from 2:30 -4 PM on Thursdays to discuss these review comments. Please contact Max Greene at 296.5832, ext. 3283, to schedule an appointment. File: CDES_rp,esc,swm_MRG_ 06 -124 East Englridge Farm Sub (aka Haffner Farm).doc