Loading...
HomeMy WebLinkAboutSDP200900031 Review Comments Preliminary Site Plan 2009-06-18COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 June 18, 2009 Ray Burkholder Balzer & Associates 1561 Commerce Road Verona VA 24482 RE: ARB 2009 -35: Collins Medical Center Tax Map 61W, Section 2, Block B, Parcel 1 A Dear Mr. Burkholder: The Albemarle County Architectural Review Board, at its meeting on June 15, 2009, completed a preliminary review of the above -noted request to construct a single -story building and associated site improvements for an oral surgery medical practice. The Board offered the following comments for the benefit of the applicant's next submittal. Please note that the following comments are those that have been identified at this time. Additional comments may be added or eliminated based on further review and changes to the plan. 1. Provide samples of all proposed building materials and colors. 2. Revise Sheet 1 of 1 Preliminary Site Plan to show the grading contours associated with the fill slopes along the west side of the building and the cut slope (elev. 452) in the southeast corner of the parking lot rounded to meet the existing condition, with the use of a 10' minimum radius. 3. Include, with your next submission, an Erosion and Sediment Control Plan showing the method and location of tree protection. Provide a tree conservation plan with measures limiting and remedying impacts on existing trees to remain along with verification from a certified arborist that all proposed grading will not be detrimental to the health of trees designated to remain. 4. Revise Sheet 1 of 1 Preliminary Site Plan to include the location of the easement boundary for the overhead power line along the Westfield Road frontage. Revise the drawing to note the distance from the ground to the lowest line. If the mature height of the 3 proposed Winter King Hawthorn trees conflicts with the location of this line, revise the proposal to show the use of a shorter tree. 5. Designs for all freestanding signage visible from the Corridor will need to meet ARB Sign Guidelines, with locations free of conflicts with utilities and landscaping. An ARB sign application for freestanding signage is an additional application that can be submitted separately from the ARB site plan application. For building signage visible from the Corridor, provide revised elevations showing the sign location along with details, including materials, colors and dimensions, of the sign design. Wall and freestanding signs will require a sign permit in addition to ARB approval. 6. Provide a lighting photometric plan showing the location of all proposed site, building and decorative lighting. Include all lighting cutsheets in the full size drawings. Provide a luminaire schedule of all proposed exterior lighting on the photometric plan, clearly indicating all lighting options chosen, including but not limited to heights and colors proposed for all fixtures and poles. All fixtures emitting 3,000 or more lumens shall be full cutoff style fixtures. 7. Revise the drawing date for Sheet 1 of 1 Preliminary Site Plan to correctly reference the year as 4- 14 -09. 8. Revise the misspelled label PATIENCE REST. on Sheet Al -101 First Floorto read PATIENT REST. 9. Regarding the cantilevered portico on the northwest elevation: a) provide support similar to the front portico using classical elements and proportions to eliminate the cantilevered appearance b) consider either engaging or more fully disengaging the fascia line from the main roof. 10. Consider eliminating the dumpster, dumpster pad and enclosure in favor of independent trash cans fully screened. You may submit your application for continued ARB review at your earliest convenience. Application forms, checklists and schedules are available on -line at www.albemarle.org /planning. Revised drawings addressing the comments listed above are required. Include updated ARB revision dates on each drawing and an ARB approval signature panel. Please provide a memo including detailed responses indicating how each comment has been addressed. If changes other than those requested have been made, identify those changes in the memo also. Highlighting the changes in the drawing with "clouding" or by other means will facilitate review and approval. If you have any questions concerning any of the above, please feel free to call me. Sincerely, Brent Nelson Landscape Planner cc: JMC Enterprise LLC - Robert Jonas Collins 1571 Duke Road Waynesboro VA 22980 Steve Hinton Design Vision 4593 Stuarts Draft Hwy Waynesboro VA 22980 File