Loading...
HomeMy WebLinkAboutSDP200900057 Review Comments Site Plan Waiver 2009-08-12*-&A County of Albemarle Department of Community Development Memorandum To: Gerald Gatobu, Current Development Project Planner From: Phil Custer, Current Development engineering review Date: 12 August 2009 Subject: Harris Garage Site Plan Waiver (SDP- 2009 - 00057) The site plan waiver, received on 27 July 2009, has been reviewed. The engineering review for current development can recommend approval to this application after the following changes: 1. As a condition of the critical slope waiver for this development, the applicant must provide mitigation planting in all areas within the stream buffer that is not currently forested. Please submit a WPO application and $85 fee for the review of a mitigation plan. Please also make the following corrections to the mitigation plan: - The stream buffer is not accurately represented on this site plan. And, since the stream buffer is not shown accurately, the mitigated area and number of required seedlings are not correctly calculated. After measuring the stream buffer area in the site plan, it appears that 0.18acres can be planted and, at a density of 1210 stems an acre, the required number of seedlings is 218. - Whatever the required number of seedlings within the buffer is, please provide a note stating that half of the mitigation plants must have survived after the first two growing seasons. The county will hold a bond for 5 years to assure that this minimum number of plants survives. - Please specify on the plan the species and height of the seedlings to be planted for mitigation. - Please provide a rough cost estimate for the purchase and labor of planting of these seedlings so that it can be bonded. 2. Please call out the Swale at the southeast corner of the plan and specify the material and dimensions. 3. A low maintenance, non -grass groundcover should be provided on any portion of the slope above the new retaining wall that is steeper than 3:1. Acceptable groundcovers can be found in Table 3.37C of the VESCH. 4. Please provide a note in the area of the dumpster pad that surface runoff is not to drain into or across the dumpster pad. File: El_spw_PBC_sdp200900057.doc