Loading...
HomeMy WebLinkAboutSDP200900062 Review Comments Preliminary Site Plan 2009-08-31 (3)vIRGIN� County of Albemarle Department of Community Development Memorandum To: Elizabeth Marotta, Planner From: John Diez, Engineering Review Division: Current Development Date: August 31, 2009 Subject: SDP200900062, Free Bridge Office - Preliminary The preliminary site plan for Free Bridge Office, received on August 11, 2009, has been reviewed. The engineering review for current development can recommend approval once the following items are adequately addressed: A. Preliminary Site Plan Comments: 1. Please provide removal rates for the pre - development and post - development drainage areas. 2. Please provide for interparcel connectivity to the neighboring parcels as shown on the approved Whitehouse Commercial Preliminary Site Plan (SDP20080020) and the Kia Site Plan Major Amendment (SDP200500135). Please designate which critical slopes (as shown on the Existing Conditions Plan) are man -made, and designate the approved plan which created them - Olympia Drive, Kia, or Free Bridge Auto (application numbers and approval dates can be researched at the Community Development Office or on -line at Countyview Web). Designate which critical slopes, if any, are natural. The disturbance of critical slopes which were not created with an approved plan will require a waiver from the Planning Commission. 4. To provide safe circulation, it is recommended that the entrance to the lower parking lot be moved farther away from Olympia Drive. A minimum tangent of 50 -feet between the two entrances is suggested. 5. Based on the 2.5:1 slope and the greater than 10 -foot drop -off, it appears that guardrail is necessary in front of the 5 proposed parking spaces in the Free Bridge Auto lot. [DM] 6. The difference in grade created between the proposed travelway and the Whitehouse Commercial site could require a guardrail on the Whitehouse site. [DM] 7. The difference in grade created between the proposed parking lot and the existing Free Bridge Auto site could require a guardrail along the existing Auto parking. [DM] B. Final Site Plan Comments (For information purposes only): Vehicle access aisles, that are not adjacent to parking spaces, shall not exceed a grade of 10 %. [18- 4.12.17a] 9. Dumpster pad cannot have drainage running beneath it. The site must be designed so that stormwater does not run through, and drains away. 10. VDOT approval must be obtained for plans that affect right -of -way prior to final site plan approval. [DSM902B] 11. A temporary grading and construction easement will be necessary from the Whitehouse Commercial parcel prior to approval of the Final Site Plan. Please provide a letter of intent to grant the easement from the owner of this parcel. 12. The boundary line adjustment and easement plats necessary to accommodate this development must be recorded prior to approval of a Final Site Plan. 13. The final site plan is subject to County Code Chapter 17 Water Protection Ordinance. Approval of a Water Protection Ordinance Application including Erosion and Sediment Control Plans per Article II will be required. To ensure that Stormwater Management and Water Quality was accounted for with the design of the Luxor Pond, please submit the allowable impervious area (or C- value) of the site, based on the Luxor Pond plans, and the actual proposed impervious area. \\ Cob- dts01 \cityviewlnk\Docs \2009 \SDP \SDP200900062 Free Bridge 0ffice \CDE1_psp_JPD_09 -00062 Free Bridge.doc