MEMORANDUM
TO:
Summer Frederick
FROM:
Margaret Maliszewski
RE:
SDP- 09 -64: Martha Jefferson Medical Office Center 3 Minor
ARB- 09 -33: Pantops Professional Building 3
DATE:
September 18, 2009
I have reviewed the revised minor amendment plan submitted for this project. The plan consisted of sheets
1 -5, some with revision date of 9/10/09.1 have the following comments:
1. My previous comment #1 has not been addressed: Outdated wording has been used for the lighting
note included as General Note #10 on Sheet 1. The note should read as follows: "Each outdoor
luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff
luminaire."
2. Spillover exceeds .5 footcandles at the property line along Route 250. The two fixtures that appear to
be creating the spillover are identified as existing fixtures moved to these proposed locations. Because
the fixtures are being moved, the spillover must meet ordinance requirements and the plan must be
revised accordingly.
3. Fixture SG exceeds 3000 lumens and does not appear to be a full cutoff fixture. Submit written
confirmation from the manufacturer that all light emitted by the fixture, either directly from the lamp
or indirectly from the fixture, is projected below the horizontal plane. Alternatively, revise the fixture
to one that is clearly full- cutoff.
4. The Atlantic fixture labeled SC in the lighting fixture schedule exceeds 3000 lumens. A cut sheet was
not provided, so a determination cannot be made regarding its full- cutoff nature. Revise the plan to
include the cut sheet. Ensure that the fixture is a full- cutoff fixture.
5. Portions of my previous comment #4 have not been addressed: the note on detail 1 /SK -X is not
legible; include a note on the plan stating that mechanical equipment shall not be visible from the
Entrance Corridor.
6. As indicated in my previous comment #4, the site plan must be coordinated with the architect's
drawings. The architect has provided a different slope condition at the mechanical equipment area, and
it includes a timber retaining wall. Please coordinate the design of this area with the architect. Revise
the site plan to match the architect's approved drawings. Alternatively, provide updated architectural
drawings that match the site plan.