HomeMy WebLinkAboutSDP200900091 Review Comments Final Site Plan and Comps. 2010-01-26 (3)�'IRGINLP
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, North Wing
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4012
January 27, 2010
Scott Collins
Collins Engineering
800 E. Jefferson Street
Charlottesville, VA 22902
RE: ARB- 2009 -99: Arden Place - Final Review of a Site Development Plan
TMP 61 -124
Dear Mr. Collins:
I have reviewed your recent submittal for the above - referenced project consisting of:
Site Plan Sheets:
• Sheet 1, Cover Sheet, latest revision date 1/5/10
• Sheet 4, Site Sections from Rio Road, latest revision date 1/5/10
• Sheet 4A, Site Sections from Rio Road, latest revision date 115110
• Sheet 5, Site Sections from Rio Road, latest revision date 1/5/10
• Sheet 6, Site Plan, latest revision date 1/5/10
• Sheet 6A, Site Plan, latest revision date 1/5/10
• Sheet 7A, Landscaping Plan, latest revision date 115110
• Sheet 713, Landscaping Plan, latest revision date 115110
• Sheet 9, Lighting & Photometric Plan, latest revision date 115110
• Sheet 9A, Lighting & Photometric Plan, latest revision date 115110
• Sheet 10, Lighting Details, latest revision date 115110
• Sheet 11, Ultimate Stormwater Management Plan, latest revision date 1/5/10
Architectural Sheets:
• Sheet A0.01, Cover Sheet, latest revision date 1/6/10
• Sheet A2.10, Building Type 2, Roof Plan Building 4, date 1/6/10
• Sheet A2.15, Building Type 3, Roof Level Buildings 1 & S, latest revision date 1-
6-10
• Sheet A2.20, Building Type 4, Roof Plan Building 2, latest revision date 1 -6 -10
• Sheet A2.22, Building Type 1, Elevations Buildings 3 & 6, latest revision date 1-
6 -10
• Sheet A2.23, Building Type 1, Elevations Buildings 3 & 6, latest revision date 1-
6-10
• Sheet A2.24, Building Type 2, Elevations Building 4, latest revision date 1 -6 -10
• Sheet A2.25, Building Type 2, Elevations Building 4, latest revision date 1 -6 -10
• Sheet A2.26, Building Type 3, Elevations Buildings 1 & 5, latest revision date 1-
6-10
• Sheet A2.27, Building Type 3, Elevations Buildings 1 & 5, latest revision date 1-
6 -10
• Sheet A2.28, Building Type 4, Elevations Building 2, latest revision date 1 -6 -10
• Sheet A2.29, Building Type 4, Elevations Building 2, latest revision date 1 -6 -10
• Sheet A2.30, Building Type 5, Elevations Building 7, latest revision date 1 -6 -10
• Sheet A2.31, Clubhouse Floor Plans, latest revision date 1 -6 -10
• Sheet A2.32, Clubhouse Elevations, latest revision date 1 -6 -10
• Sheet A2.33, G -1 Garages, latest revision date 1 -6 -10
• Sheet A2.34, G -2 Garages, latest revision date 1 -6 -10
• Sheet A4.02, Perspectives, latest revision date 1 -6 -10
Outstanding issues that will need to be further addressed are shown in italics after the
original comment from the Action Letters of January 12, 2010 and January 26, 2010.
1. Revise the landscape drawings to show medium size shade trees, 2 1 /2" caliper min,
40' on center, along the full length of the eastern boundary line. Provide the
manufacturer's name and product ID for the retaining wall materials on the landscape
plan.
Issue: Sheets 7A & 7B Landscaping Plan show 15 Weeping Willow trees in a
continuous line along the eastern boundary. The Weeping Willow is a relatively short
lived and weak wooded tree that is inappropriate adjacent to a parking area. The use
of a continuous line of the same species results in a wall -like appearance that is
contrary to the Board's expressed desire for a naturalistic landscape design.
Replacing the Weeping Willow species with a species such as Willow Oak or White
Oak, interspersed with the other species shown along the eastern boundary, would be
more appropriate. Alternating (interspersing) the species for the full length of the
eastern boundary is essential in creating a naturalistic appearance. The number of
trees of the same species, shown adjacent to each other, should be limited to a
maximum of three.
Sheet 8 "Landscaping Notes and Details", containing the retaining wall detail with
product ID, was not included with this submission.
Recommendation: Revise Sheets 7A & 7B Landscaping Plan by replacing the
Weeping Willow species with a Willow Oak or White Oak species, 21 /z" caliper
minimum, 40' on center. Revise the layout of trees species along the eastern
boundary by alternating (interspersing) species so that the number of trees of the
same species, shown adjacent to each other, is limited to a maximum of three.
2. Revise the lighting proposal to include all exterior building lighting. All such lighting
with 3,000 lumens or more shall meet full cut off requirements. Revise Sheets 6 and 6
A Site Plan and Sheets 7, 7A and 7B Landscaping Plan by correcting site
lighting /tree conflicts in the following locations:
• The proposed Green Ash (FP) at the west end of Building 5.
• The proposed Allee Elm (UP) at the northeast corner of Building 4.
• The proposed Crape Myrtles (LI) at the east and west ends of the parking lot
adjoining the southeast side of Building 1.
Issue: The Luminaire Schedule, shown on Sheet 9, does not contain the proposed
building fixtures A, B, C and D. All lighting, 3,000 lumens or greater, must be in a
full cutoff style fixture.
Recommendation: Revise Sheet 9 Luminaire Schedule to include the proposed
building fixtures A, B, C and D. Provide full cutoff style fixtures for all lighting
emitting 3,000 lumens or greater.
3. Revise the landscape proposal around the pond to have a variety of native trees and
ground cover planted in a naturalistic pattern using plant material from the County's
approved list.
Issue: This issue was not addressed in this latest submission
Recommendation: Revise the landscape proposal around the pond to have a variety
of native trees and ground cover planted in a naturalistic pattern using plant material
from the County's approved list.
Please provide:
1. Two copies of the applicable drawings addressing these issues.
2. The attached "Revised Application Submittal" form. This form must be returned
with your revisions to ensure proper tracking and distribution.
When staff s review of this information indicates that all conditions of approval have
been met, a Certificate of Appropriateness may be issued. If you have any questions,
please do not hesitate to contact me.
Sincerely,
Brent Nelson
Landscape Planner
cc: Andy McGinty (via email)
File
COUNTY OF ALBEMARLE
Department of Community Development
REVISED APPLICATION SUBMITTAL
This form must be returned with your revisions to ensure proper tracking and distribution.
County staff has indicated below what they think will be required as a resubmission of revisions.
If you need to submit additional information please explain on this form for the benefit of the
intake staff. All plans must be collated and folded to fit into legal size files, in order to be
accepted for submittal.
TO:
Brent Nelson DATE:
PROJECT NAME: ARB2009 -00099 Arden Place
Submittal Type Requiring Revisions O indicates submittal
Code
County Project Number
# Copies
Erosion & Sediment Control Plan (E &S)
# Copies
Distribute To:
Mitigation Plan (MP)
2
Brent Nelson
Waiver Request (WR)
Stormwater Management Plan (SWMP)
Road Plan (RP)
Private Road Request, with private /public comparison
(PRR)
Private Road Request — Development Area (PRR -DA)
Preliminary Site Plan (PSP)
Final Site Plan (or amendment) (FSP)
Final Plat (FP)
Preliminary Plat (PP)
Easement Plat (EP)
Boundary Adjustment Plat (BAP)
Rezoning Plan (REZ)
Special Use Permit Concept Plan (SP -CP)
Reduced Concept Plan (R -CP)
Proffers (P)
Bond Estimate Request (BER)
Draft Groundwater Management Plan (D -GWMP)
Final Groundwater Management Plan (F -GWMP)
Aquifer Testing Work Plan (ATWP)
Groundwater Assessment Report (GWAR)
Architectural Review Board (ARB)
ARB2009 -99
Other: Please explain
(For staff use only)
Submittal Code
# Copies
Distribute To:
Submittal Code
# Copies
Distribute To:
ARB
2