HomeMy WebLinkAboutSDP200800127 Review Comments Preliminary Site Plan 2010-03-24vIRGIN�
County of Albemarle
Department of Community Development
Memorandum
To:
Summer Frederick, Planner
From:
Amy Pflaum, Engineering Review
Rev. 1
John P. Diez
Division:
Current Development
Date:
August 29, 2008
Rev. 1
October 24, 2008
Rev. 2
December 4, 2009
Rev. 3
March 24, 2010
Subject:
SDP200800127, SOCA Fieldhouse - Preliminary
The preliminary site plan for the SOCA Fieldhouse, received on March 4, 2009, has been reviewed. The
engineering review for current development can recommend approval once the following items are
adequately addressed:
Plans need to be stamped and signed by a licensed professional.
(Rev. 1) Comment has not been addressed
(Rev. 2) Comment has been addressed
2. Please provide benchmark information on the plans.
(Rev. 1) Comment has not been addressed
(Rev. 2) Comment has been addressed
3. Please designate the proposed dumpster location on the plan.
(Rev. 1) Comment has not been addressed.
(Rev. 2) Comment has not been addressed. Any commercial or industrial building of four
thousand (4000) gross square feet or more shall provide a dumpster pad. [18- 4.12.13e]
(Rev. 3) Comment has been addressed by the addition of a rolling dumpster on the Colvin
Alley side of the building.
4. Please verify that the pipe from the existing storm drain is sized to carry overflow from the cistern.
(Rev. 1) Comment has not been addressed.
(Rev. 2) Comment has not been addressed. Please verify the existing 30" RCP (ID: D -106 to
D -105).
(Rev. 3) This comment will be addressed with the Final Site Plan.
5. Sheet 02 specifies 88 parking spaces are required; however, only 18 spaces are shown on the
plans. Please specify and show all required parking spaces on the plans.
(Rev. 1) Comment has not been addressed. The resubmitted plans now state that 90 spaces
are required. However, only 50 spaces are shown on the plans. Please specify and show all
required parking spaces on the plans.
(Rev. 2) Comment has not been addressed. Parallel parking spaces must be 9' x 20' (with a
minimum aisle width of 20'. In addition, sidewalks abutting parking must be 6' wide
(exclusive of curb), or bumper blocks are provided. Please refer to the Design Standards
Manual.
(Rev 3.) Parallel parking spaces are correct. Sidewalk has been increased to 6 -foot width.
Parking spaces 2 and 3 have been moved away from the entrance onto Colbert Street.
Street sections approved with ZMA200400007 describe Cole and Colbert Streets as having
"Informal Parking ", but no parking lane dimensions are shown. Approved street plans for
these two streets, show 214 -foot wide travel lanes, parking is not mentioned. Zoning
Administrator must determine if these required parking spaces may use the Informal
Parking anticipated on the streets.
6. Please label the public access easement over Colvin Alley with the deed book and page number.
(Rev. 1) Comment has not been addressed
(Rev. 2) Comment has been addressed
Please label all existing drainage easements with the deed book and page number.
(Rev. 1) Comment has been addressed
8. Please verify and label the kind of surface that will be used in the hatched area by the terrace. Has
this been included in the impervious surface calculations?
(Rev. 2) Comment has been addressed
The following comments will need to be addressed before the final site plan can be approved:
9. The owner of this site needs to be a party to a Stormwater Management Maintenance Agreement
for the biofilter with the owner of Parcel K (Open Space).
(Rev. 2) Comment has been noted.
10. VDOT approval is needed for work within the VDOT right -of -way.
(Rev. 2) Comment has been noted.
\\ Cob- dts01 \cityviewlnk\Docs \2008 \SDP \SDP200800127 SOCA Fieldhouse - Preliminary\E3_psp_JPD_08 -00127 SOCA
Fieldhouse.doc