Loading...
HomeMy WebLinkAboutSDP201000028 Review Comments No Submittal Type Selected 2010-04-27c��pF AL &FA9'P �'IRGINIP County of Albemarle Department of Community Development Memorandum To: Tom Gale From: Gerald Gatobu, Principal Planner Division: Zoning and Current Development Date: April 27, 2010 Subject: SDP2010 -00028 Keswick Tennis Court Addition - Minor The County of Albemarle Division of Zoning and Current Development will grant or recommend approval of the minor site plan referred to above once the following comments have been addressed: [Each comment is preceded by the applicable reference, which is to the Subdivision /Zoning Ordinances unless otherwise specified.] ❑ 32.5.6 The minor site plan shall contain the following information 1. Please add the latest Special Use Permit number SP200800042 to the list under zoning. 2. Add to the Minor Amendment the Site Development Project number SDP201000028 to the minor amendment for future reference. 3. A photometric plan will be required. Please provide a Lighting plan that meets the requirements of section 4.17. The lighting plan must consist of a photometric plan prepared using the calculation grid method that will show light levels in foot - candles point by point distributed at regular intervals across the site. Please refer to the lighting review checklist below for guidance. 32.6 FINAL SITE PLAN CONTENT LIGHTING PLAN REVIEW CHECKLIST ❑ Lumen level (3000 or more must be full cutoff) Please indicate if any of the fixtures will emit more than 3000 lumens. If so, the fixtures need to be full cut off and cut sheets must be provided. Cut sheets have been provided, and lumen levels have been identified. This information needs to be shown on a lighting plan sheet that will be part of the minor amendment. Please contact me for examples of li htin lans . ❑ Bulb/lamp location (must be totally within house to be full cutoff) The light fixture must be totally within the house of the fixture to be full cutoff. The fixture shown is totally within the house of the fixture. Thank you. This information needs to be incorporated into a lighting plan, Luminaire schedule Please provide a luminaire schedule. The luminaire schedule on exhibit B is hard to read. Please make this larger and make it part of the Lighting Plan. ❑ Catalog # coordinated with cut sheets Catalog #'s must coordinate with provided cut sheets. The catalog numbers shown in the luminaire schedule should match those that are indicated on the cut sheets. ❑ Fixture quantity /types coordinated with quantity /types on lighting plan Fixture guantity/types on the luminaire schedule must coordinate with quantity /type on the lighting plan. Exhibit B provides some of this information but it is difficult to read. Please provide this information on a lighting plan and make the information large enough to read. ❑ Pole height/moanting height (ARB) N/A ❑ Colors /finishes (ARB) N/A ❑ Tilt (must be 0 for full cutoff) Please make sure the tilt on any of the fixtures is 0 Fixture locations ❑ Location conflicts with trees, utilities, etc. Make sure the location of fixtures does not conflict with trees, utilities, etc. ❑ Coordination with other site plan sheets Fixtures locations must coordinate with other features shown on other site plan sheets. ❑ Shielding issues (freestanding signs, wall fixtures, etc.) Make sure all wall fixtures are properly shielded. Non ro osed Photometric plan ❑ Adjacent zoning Spillover onto public roads, residential areas, and rural areas may not exceed .5 footcandles at the property line or edge of right -of -way or easement, whichever is closer to the light source. Please provide a lighting plan with a Photometric plan. ❑ Property lines Spillover on adiacent property lines need to be determined. Spillover onto public roads, residential areas, and rural areas may not exceed .5 footcandles at the property line or edge of right -of -way or easement, whichever is closer to the light source. A photometric plan is required to determine spillover at the property line and edge of the right of way. ❑ Excessive spillover Please provide a photometric plan that will help in determining the amount of spillover. ❑ Excessive lighting levels (ARB) N/A ❑ Maintenance factor = 1.0 Maintenance factor must to be 1.This number is generally located in the Luminaire Schedule. This is correctly shown, but needs to be incorporated into a lightinI4 plan that will be part of the minor amendment. ❑ Standard lighting notes Please add the standard lighting note to the site plan. "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire. The spillover of lighting from luminaires onto public roads and property in the residential or rural areas zoning districts shall not exceed one -half footcandle. "