HomeMy WebLinkAboutWPO201000041 Review Comments Erosion Control Plan 2010-08-05� OF AL ,. vIRGI1`IZP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: Old Trail Village Block 4, Final Before Preliminary Site Plan; SDP-2010-00055 Plan preparer: Collins Engineering Owner or rep.: March Mountain Properties, LLC Plan received date: 12 July 2010 Date of comments: 5 August 2010 Reviewer: Phil Custer A Water Protection Application was received at the same time as the site plan. Engineering review provides the following comments on the WPO submittal: a. Water Quantity requirements will be met by the existing detention basin northwest of Block 3 that this site drains to, as anticipated by Sheet 3 of the Rezoning Plan. b. Water Quality requirements will be met with the payment of the Lickinghole Fee. The cost for Block 4 will be calculated closer to the time of site plan approval. This payment must be provided prior to the issuance of a grading permit for the construction of the buildings. c. An ESC plan is needed for the work shown on this site plan. The ESC plan (WPO -2008- 00106) is not sufficient for the site construction shown within the plan. When the ESC plan is submitted please show the limits and all necessary measures of previously approved ESC plans. The other WPO numbers should be referenced throughout the application and clearly indicate that this ESC will rely on active plans on the Old Trail Property. d. Because no WPO reviews were performed (no ESC plan submitted and SWM requirements met without technical review), there will be a $600 credit towards this application. e. Please note that the WPO approval for Block 2 (WPO- 2009 - 00026) has expired. [17- 204.G] 2. The pipe from the 4 drainage structures within the first 100ft of Upland Drive should remain in the VDOT ROW and continue to be routed to the intersection with Claremont Drive. If these pipes must absolutely be routed through Block 4, the system will not be maintained by the County. The easement restrictions on these pipes will need to be worked out with VDOT, the applicant, and the County's Attorney's office. The easiest solution may simply be to call the easement through the property a private drainage easement. 3. The plan does not match the previously approved road plans for Upland and Claremont. It appears this site plan is contingent on the changes to the road sections of this plan. Also, because this site plan is contingent on the construction of Claremont in order to grant access to the site, the limits of the site plan must be extended to eastern ROW line of Claremont. All design information for Claremont must be included in this set as well. 4. Do the houses on Lots 33 -39 have front doors facing Upland Drive? If so, please show the sidewalk from the door to the sidewalk within the VDOT ROW. [18- 32.7.2.8] 5. The sidewalk in the "grassed mall" must connect to the sidewalk surrounding the block: a. East of the handicap parking space show a 5ft sidewalk with handicap ramp oriented towards the grass mall sidewalk. [18- 32.7.2.8] b. Similarly, provide a pedestrian connection from the south side of the grass mall to Upland Albemarle County Community Development Engineering Review Comments Page 2 of 2 Dr. If the four -unit building was switched with the three -unit building, a connection can be made between the buildings. [18- 32.7.2.8] 6. The plan indicates a curb, both graphically and with the contours, at each driveway. Please show driveways at the grade of the existing pavement in the alley. 7. The driveways for lots 6, 7, and 8 are too steep. Please flatten to 5 %. [18- 4.12.15.c] 8. Please show a private drainage easement on lot 18 for the mall drainage system that passes through it. 9. Parallel parking spaces must be 9ft wide. [ 18- 4.12.16.c.2] 10. A short 20% grade is shown on a sidewalk east of Lot 40. Are steps necessary here? Does this sidewalk need to meet ADA requirements? 11. The dead -end alleys must be 14ft from curb -to -curb. [14 -410] 12. The plan shows a sewer line that runs through Blocks 13 and 2. This sewer line must be shown on this site plan. The ESC plan for this block must include the construction of this sewer line within its limits of disturbance. 13. Please specify the structure and grate type in the Storm Sewer Profiles. [DM]