HomeMy WebLinkAboutSUB201000048 Review Comments Miscellaneous Submittal 2010-08-16r � P. F f N COMMONWEALTH EALTH ®f VIRGINIA In Cooperation with the Thomi -is Jeffet-son Health Distilet ALBE? ARLE -CHARLOTTESVILLE State Department of Health FLUVANNA COUNTY(PALMYRA) 1138 Rose Hill Drive GREENE COUNTY (STANARDSVILLE) LOUISA COUNTV(LOUISA) Phone (434) 972 -6219 P. O. Box 7546 NELSON COUNTY (LOVINGSTON) Fax (434) 972 -4310 Charlottesville, Virginia 22906 May 03, 2010 Ellizabeth Marotta, Senior Planner Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 RE: Review of Proposed Subdivision Plat and attached Soils Information for Individual Onsite Sewage System for TM 26, Parcels 33B Dear Ms. Marotta, On April 30, 2010, the County of Albemarle requested the Virginia Department of Health (via the Albemarle County Health Department) review the proposed subdivision plat identified above. This letter is to inform you that the above referenced subdivision plat is approved for individual onsite sewage systems in accordance with the provisions of the Code of Virginia, and the Sewage Handling and Disposal Regulations (12 VAC 5- 610 -10 et seq., the `Regulations "), (and local ordinances if the locality has authorized the local health department to accept private evaluations for compliance with local ordinances).. This request for subdivision review was submitted pursuant to the provisions of § 32.1 -163.5 of the Code of Virginia which requires the Health Department to accept private soil evaluations and designs from an Authorized Onsite Soil Evaluator (AOSE) or a Professional Engineer worldng in consultation with an AOSE for residential development. This subdivision was certified as being in compliance with the Board of Health's regulations by: Steven Gooch, AOSE #106. This subdivision approval is issued in reliance upon that certification. Pursuant to § 360 of the Regulations this approval is not an assurance that Sewage Disposal System Construction Permits will be issued for any lot in the subdivision identified above unless that lot is specifically identified on the above referenced plat as having an approved site for an onsite sewage disposal system, and unless all conditions and circumstances are present at the time of application for a permit as are present at the time of this approval. This subdivision may contain lots that to do not have approved sites for onsite sewage systems. This subdivision approval is issued in reliance upon the certification that approved lots are suitable for "traditional systems," however actual system designs may be different at the time construction permits are issued. This subdivision approval does pertain to the requirements of local ordinances. Sincerely, /�V- 4�� Kelly L. Donahoe Environmental Health Specialist Senior Commonwealth of Virginia Application for Subdivision Review (Page 1 of 2 to be filled out by the Owner or Agent) Owner Sheridan Estate Mailin Address 5212 Walnut Level Road VDH Use Only Health Department ID# Due Date Phone (434) 823 -186' g Phone Crozet, Virginia 22923 Fax Developer /Agent Gooch Engineering and Testing P1011e (434) 293 -7449 Mailing Address 1821 Broadway Street Phone Charlottesville, Virginia 22902 Fax AOSE Steve Gooch Phone (434) 531 -0487 Mailing Address 1821 Broadway Street Phone Charlottesville, Virginia 22902 Fax Directions to Property: From White Hall 810 towards Browns Cove, left on Slam Gate Road to property on right past Montfair Campground Name of Proposed Subdivision Tax Map 26 -33B Other Property Identification Dimension/Acreage of Property 7.42 Ac. Number of lots proposed 2 Proposed water source (note: new or existing, public or individual) new, individual General size of lots 3.71 ac. (give range if appropriate) Additional description of subdivision Overview of soils and geology (optional but encouraged) In order for VDH to process a subdivision application you must attach a plat of the property showing the location of the proposed onsite sewage disposal systems and the reserve absorption areas (if required) and the location of the water supply system on each lot, if applicable. Each plat or subsection of a subdivision shall be accompanied by specific soil information for each lot (absorption area and reserve area). If not provided by the local subdivision ordinance, the district or local health department may require the plat to show streets, utilities, storm drainage, water supplies, easements, lot lines, and original topographic contour lines by detail survey or other information as required. When the AOSE site evaluations are reviewed, the property lines, building location and the proposed well and sewage system sites must be clearly marked and the property sufficiently visible to see the topography, otherwise this application will be denied. I give permission to the Virginia Department of Health (VDH) to enter onto the property described during normal business horns for the purpose of processing this application and to perform quality assurance checks of evaluations and designs certified by an Authorized Onsite Soil Evaluator (AOSE) or a Professional Engineer (PE) as necessary until the sewage disposal ssal system has been constucted and approved. ` Signature of owner /Agent Date Commonwealth of Virginia Application for Subdivision Review (page 2 of 2 to be filled out by the county official requesting a VDH review) County Office initiating request Contact individual VDH Use Oaly Health Depanmenl IDp Due Dale Phone Local offices of the Virginia Department of Health may review subdivision applications for compliance with stale rules and regulations governing sewage treatment and dispersal and private watersupplies, compliance with Iota! ordinance governing sewage treatment and dispersal and private water supplies and potentially for compliance with other local ordinances. Please indicate the nature of review you are asking the health department to conduct. 1. Review for conformance with the Sewage Handling and Disposal Regulations 2. Review for conformance with local onsite wastewater ordinances 3. Other (describe below) Name and title ofrequestor Date ROSE Form F Revised 9/29104 COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone(434)296 -5832 Fax(434)972 -4126 April 28, 2010 Teresa Batten Virginia Department of Health 1138 Rose Hill Drive Charlottesville, VA 22906 RE: SUB- 2010 -48 Sheridan Estate- Final Dear Ms. Batten: �c A43 ENVIRONMENTAL HEALTH The County of Albemarle has received application to develop /subdivide [Tax Map 26, Parcel 33B]. This project requires Health Department approval before receiving final County approval. The applicant has provided soils information, which is attached. Please review the proposal for suitable subsurface drainfields which comply with the provisions of Chapter 18, Sections 4.2.2, 4.2.3, 4.2.4, and Chapter 14, Sections 14 -309 and 14 -310 of the Albemarle County Code. Should you have any comments please feel free to contact me. Sincerely, Elizabeth M. Marotta, Senior Planner Department of Community Development Voice: (434) 296 -5832 ext. 3432 Fax: (434) 972 -4035 3 s � Soil Study for Drain Field Sites Lots 2A and 2B A Division of Lot 2 The Mary B. Sheridan Property Albemarle County, Virginia Prepared for: Sheridan Estate c/o Leora Sheridan Vincenti 5212 Walnut Level Road Crozet, Virginia 22932 Prepared by: Gooch Engineering & Testing, Inc. �� 1821 Broadway Sheet APPRO V' Charlottesville, VA 22902 April 24, 2010 Gooch Engineering and Testing, Inc. Page 1 of AOSE Report for SUBDIVISION APPROVAL Location of property: Lot 2A Section _, Subdivision Sheridan Estate Albemarle County GPIN or Tax Map # 26 -33B Latitude /Longitude Applicant or Client and address: Prepared by AOSE (name and address): Sheridan Estate Steve Gooch 5212 Walnut Level Road 1821 Broadway Street Crozet, Virginia 22932 Charlottesville, Virginia 22902 Date of Report: 4 -24 -10 AOSE Job Number: (optional) Revision Date: , Health Dept. ID. No.: Contents /Index of this report: AOSE Cover Sheet Abbreviated Design Forms Soil Profile Sheet Survey Plat Soil Summary Report Certification Statement(s) I hereby certify that the evaluations and/or designs contained herein in E o F` were conducted accordance with the Sewage Handling and Disposal Regulations / (12 VAC5-610), the Private Well Regulations VAC5-615), and other applicable policies of the Virginia Department of Health. Furthermore, I certify that my ° PI t7JJ0 /Jejfj{��' ST E HEN G evaluation and /or design contained herein complies with all ZD applicable laws, regulations, and policies implemented by the ° o LIC. No. 1o6 Virginia Department of Health. yp rp, Q, J I reconuuend a subdivision approval be approved �t 0 JQv ���NSITE SO \�� UPROVED Soil Profile Lot 2A A Division of Lot 2 The Mary Sheridan Property Albemarle County Hole Depth Horizon Material Description Soil Texture (in.) Group 1 0 -2 A Dark gray (I OYR 4/1) loam 2 2 -29 Bt Red (1 OR 5/8) silty clay loam 3 29 -60 BC Red (1 OR 5/8) silty clay loam and yellow (10YR 7/8) clay 3 loam 60 -84 C Reddish yellow (5YR 6/8) clay loam 3 2 0 -2 A Dark gray (1 OYR 4/1) loam 2 2 -17 Bt Red (I OR 5/8) silty clay loam 3 17 -62 BC Reddish yellow (7.5YR 6/8) clay loam 3 62 -84 C Yellowish brown (I OYR 5/8) sandy loam 2 3 0 -3 A Dark gray (10YR 4/1) loam 2 3 -30 Bt Yellowish red (5YR 5/8) silty clay loam 3 30 -84 C Brownish yellow (1 OYR 6/8) sandy loam 2 4 0 -2 A Dark gray (I OYR 4/1) loam 2 2 -30 Bt Yellowish red (5YR 5/8) silty clay loam 3 30 -84 C Brownish yellow (I OYR 6/8) sandy loam 2 5 0 -3 A Dark gray (I OYR 4/1) loam 2 3 -25 Bt Red (I OR 5/8) silty clay loam 3 25 -84 C Brownish yellow (1 OYR 6/8) clay loam, some sand 3 Page --'L of .( Appendix 2 Soil Summary Report GENERAL INFORMATION Date 4 -24 -10 Submitted to Albemarle County Health Department Applicant Sheridan Estate Telephone Number Address 5212 Walnut Level Road Crozet, Virginia 22932 Owner same Address same Location Slam Gate Road Tax Map 26 -33B Subdivision Sheridan Estate Block/Section Lot 2A SOIL INFORMATION SUMMARY 1. Position in landscape satisfactory? rX Yes j- No Describe side slope 2. Slope 20 % 3. Depth to rock or impervious strata: Max. Min. None x 4. Depth to seasonal water table (gray mottling or gray color) (X No F- Yes inches 5. Free water present 1X- No r Yes range in inches 6. Soil percolation rate estimated R Yes Texture group I II (D IV F- No Estimated rate 55 min /inch 7. Permeability test performed 1- Yes Fx No If yes, note type of test performed and attach r Site Approved: Drainfield to be placed at 60„ depth at site designated on permit. (- Site Disapproved: Reasons for rejection: 1. r- Position in landscape subject to flooding or periodic saturation. 2. F- Insufficient depth of suitable soil over hard rock. 3. F- Insufficient depth of suitable soil to seansonal water table. 4. r Rates of absorption too slow. 5. f Insufficient area of acceptable soil for required drainfield, and /or Reverse Area. 6. F- Proposed system too close to well. 7. r- Other Specify (attach additional pages if ne - �ssary) PU-A q F-6 Abbreviated Design Form This form is for use with gravity, pump to gravity, enhanced flow, and low pressure distribution (LPD) sewage system designs and when applying for a certification letter or subdivision approval. This abbreviated design covets the ❑ primary and reserve area, 5?*66'ily the primary area, ❑ only the reserve area (check one) for _Sheridan Estate — Lot 2A (Property ID). Design Basis Total length of available area: 100' Total width of available area: 43' Estimated Pere. Rate: _55 at 60" in. (depth) Number of bedrooms (or GPD): 3 r 2 Conveyance Method : Gravi Distribution method (specify): Gravity s� Dispersal system basis Table 5.4 LGMI required? No (Yes/No) Effluent quality required: Primary (Primary, Secondary, Advanced Secondary) Square feet per bedroom: 412 Total trench bottom area required: 1236 Area Calculations Number of trenches 5 Length of trenches: 95' Width of trenches: 3' Center to center spacing: 10' Reserve required? yes _ Percent reserve area required: 100 Total width of absorption area required _43' Total trench bottom area provided: 1425 The required width is calculated by multiplying the center -to- center spacing by one less than the number of trenches and adding 1 trench width plus any required reserve area. If the topography is not uniform across the length of the site the trenches will need to flare apart on one end to maintain contour. When this occurs it is necessary to use a center -to- center spacing that accounts for the flair or the installer will not be able to fit the system within the approved area. It is perfectly acceptable to have more area available, especially up and down the slope, than is required. Page _ of AOSE Fom E Revised July r8, 2007 Abbreviated Design Form uF- � This form is for use with gravity, pump to gravity, enhanced flow, and low pressure distribution (LPD) sewage system designs and when applying for a certification letter or subdivision approval. This abbreviated design covers the t7 primary and reserve area, ❑ only the primary area, tff"e'lily the reserve area (check one) for Sheridan Estate — Lot 2A (Property ID). Design Basis Total length of available area: 100' Total width of available area: 30' Estimated Pere. Rate: 55 at 60" in. (depth) Number of bedrooms (or GPD): 3 r z Conveyance Method : _Gravi Distribution method (specify : Gravi 3c Dispersal system basis GMP 118A LGMI required? No (Yes/No) Effluent quality required: Secondar (Primary, Secondary, Advanced Secondary) Square feet per bedroom: 185 Area Calculations Number of trenches 3 Width of trenches: 3' Reserve required? this is reserve Total trench bottom area required: 555 Length of trenches: 100' Center to center spacing: I O' Percent reserve area required: 100 Total width of absorption area required _20' Total trench bottom area provided: 900 The required width is calculated by multiplying the center -to- center spacing by one less than the number of trenches and adding I trench width plus any required reserve area. If the topography is not uniform across the length of the site the trenches will need to flare apart on one end to maintain contour. When this occurs it is necessary to use a center -to- center spacing that accounts for the flair or the installer will not be able to fit the system within the approved area. It is perfectly acceptable to have more area available, especially up and down the slope, than is required. Page _ of AOSE Form E Revised July 18, 2007 FLAG, FLAG P r�fic3Id !y 2I C LA0 - '• _ T •FLAG PROPOSED : 05 SEPTIC •.••r••_.• :m ORAINFIELO "' 204 _... , 00 AREA 4-200 ...... .:N REVISED TRACT C MARY 8:SHERIDAN G u �- 6 0:B.3847 -320 7��00 W.13.99-444 D.B.1608 -297 & 303 0 00o, D.B.416 -477 PLAT F IRON FOUND X FLAG B1 FLAG ti;ti �N 82 ti 2W o ± : sI N`ii i? proposed Prlrn* Drair> fold X n o o p �p ✓�00 p ^� : FOUND (� N75 • p - FLAG Ncp. y; ®S 0 well Sit 2° W :�j FLAG . III`II FLAG r�\ NFL ® A2 I posed Res( Q ;Q IRON rm M FOUND 1 �, r�I ``�`` ; infield 32 ni: o 0 y00 A y : ® \� `LAG o 1NT Cn P .^ P1.. 4XU�G 9 A4 p YANT \p` A G. PRmoseG )RIDGE 247 ' �� i,9�gA,SGe' CCFS'S' �. OFiA�AEIA Ni9cS N3 412 24 PLAT o V _ ;.` ° DESC. S7 �F9 EASEMENTS s ° \qM Nag .00 00 20. f LOT 2A W 180 TEI °o \_3,71 ACRES PEI \ T9 17.65' IROP / Fq BUFFER FOUN STONE IRON7� IRON. IRON FOUND FOUND FOUND FOUND p0 '58 "W FOUND IRON C P�, 56.62' STATE FOUND , } W N S55'3E -- �AOU %E 6 C2. a 37.1 1 l� R/W NG EASEMENT N72'40'03 "W ` - SIGHT DISTANCI 75.68' (D. B. S71'14'30'W 15.91'. LINE DELTA RADIUS ARC TANGEN' Scale I" =100' •- Soil Profile Dole C1 16'16'06." 640.09 181.74 91.E C2 35''25' 11 ".. 250.24 154:69 79.5 House, Well and Drain Field Sites C3 2&'.19'46" 213.75 98.23 50. C Lot 2A A Division of Lot 2 The Mary Sheridan Property SCALE:_ V ._ 100 DATE: Albemarle County, Virginia Gooch Engineering & Testing, Inc. GRAPHIC SCALE 1821 Broadway Street Charlottesville, Virginia 22902 n Inn Pnn '4 nn Gooch Engineering and Testing, Inc. Page 1 of ;? AOSE Report for SUBDIVISION APPROVAL Location of property: Lot 2B Section _, Subdivision Sheridan Estate Albemarle County GPIN or Tax Map # 26-338 Latitude /Longitude Applicant or Client and address: Prepared by AOSE (name and address): Sheridan Estate Steve Gooch 5212 Walnut Level Road 1821 Broadway Street Crozet, Virginia 22932 Charlottesville, Virginia 22902 Date of Report: 4.24 -10 AOSE Job Number: (optional) Revision Date: Health Dept. ID. No.: 2ontents /Index of this report: 40SE Cover Sheet Abbreviated Design Forms Soil Profile Sheets Survey Plat Soil Summary Reports A,PP,qo Vj V 1 hereby certify that the evaluations and/or designs contained ��\ k herein were conducted in accordance with the Sewage Handling tI and Disposal Regulations (12 VAC5-610), the Private Well Regulations (12 VAC5-615), and other applicable policies of the pVO� f�I��JLj'� ��NG-000 r Virginia Department of Health. Furthermore, I certify that my T evaluation and/or design contained herein complies with all implemented by q 9 Z, Lie. NO. 106 applicable laces, regulations, and policies the Department Health. yp Virginia of I recommend a subdivision approval be approved 0 \V ONSITF SO J' A,PP,qo Vj V Soil Profile Lot 2B A Division of Lot 2 The Mary Sheridan Property Albemarle County Hole Depth Horizon Material Description (in.) 3 4 5 C 7 Primary Drain Field eal, z&C-8 Soil Texture Group 0 -2 A Dark gray (I OYR 4/1) loam 2 2 -5 BE Brown (7.5YR 4/3) clay loam 3 5 -50 Bt Red (I OR 5/8) silty clay loam 3 50 -72 BC Yellowish red (5YR 5/8) clay loam, some sand 3 72 -84 C Yellowish brown (1 OYR 5/8) sandy loam 2 0 -2 A Dark gray (10YR 4/1) loam 2 2 -12 BE Brown (7.5YR 4/3) clay loam 3 12 -32 Bt Red (I OR 5/8) silty clay loam 3 32 -56 BC Yellowish red (5YR 5/8) clay loam, some sand 3 56 -84 C Pink (7.5YR 7/4) clay loam, some sand 3 0 -2 A Dark gray (I OYR 4/1) loam 2 2 -9 BE Brown (7.5YR 4/3) clay loam 3 9 -44 Bt Red (I OR 5/8) silty clay loam 3 44 -60 Bt2 Red (2.5YR 5/8) silty clay loam, white feldspar 3 60 -84 C Yellow (I OYR 7/6) clay loam 3 0 -2 A Dark gray (I OYR 4/1) loam 2 2 -6 BE Brown (7.5YR 4/3) clay loam 3 6 -32 Bt Red (1 OR 5/8) silty clay loam 3 32 -46 Bt2 Red (2.5YR 5/8) silty clay loam, white feldspar 3 46 -84 C Yellow (1 OYR 7/6) sandy loam 2 0 -4 A Dark gray (1 OYR 4/1) loam 2 2 -7 BE Yellowish brown (I OYR 5/6) clay loam 3 7 -26 Bt Red (I OR 5/8) silty clay loam 3 26 -48 BC Yellowish red (5YR 5/8) clay loam, some sand 3 48 -84 C Reddish yellow (7.5YR 6/8) sandy loam 2 Reserve Drain Field 0 -2 A Dark gray (10YR 4/1) loam 2 2 -10 E Light yellowish brown (2.5Y 6/4) clay loam 3 10 -56 Bt Red (1 OR 5/8) silty clay loam 3 56 -84 C Pale yellow (2.5Y 7/4) sandy loam 2 0 -4 A Dark gray (IOYR 4/1) loam 4 -12 BE Brown (7.5YR 4/3) clay loam 12 -48 Bt Yellowish red (5YR 5/8) silty clay loam 48 -66 Bt2 Red (2.5YR 5/8) silty clay loam, olive yellow (5Y 6/8) mottles 66 -84 C Light red (2.5YR 6/8) clay loam, some sand 0 -4 A Dark gray (IOYR 4/1) loam 2 -7 BE Yellowish brown (IOYR 5/6) clay loam 7 -26 Bt Red (1 OR 5/8) silty clay loam 26 -48 BC Yellowish red (5YR 5/8) clay loam, some sand 48 -84 C Reddish yellow (7.5YR 6/8) sandy loam Page .� of Appendix 2 Soil Summary Report GENERAL INFORMATION Date 4 -24 -10 Submitted to Albemarle County Health Departmpnt Applicant Sheridan Estate Telephone Number Address 5212 Walnut Level Road Crozet, Virginia 22932 Owner same Address same Location Slam Gale Road Tax Map 26 -33B Subdivision Sheridan Estate Block/Section Lot 2B SOIL INFORMATION SUMMARY - n 1. Position in landscape satisfactory? r Yes F- No Describe side slope 2. Slope 11 % 3. Depth to rock or impervious strata: Max. Min. None x 4. Depth to seasonal water table (gray mottling or gray color) (X No I- Yes inches 5. Free water present r No r Yes range in inches 6. Soil percolation rate estimated FX Yes Texture group 1 II II IV r- No Estimated rate 75 min /inch 7. Permeability test performed r Yes No If yes, note type of test performed and attach fX' Site Approved: Drainfield to be placed at 60" depth at site designated on permit. F- Site Disapproved: Reasons for rejection: 1. I- Position in landscape subject to flooding or periodic saturation. 2. F- Insufficient depth of suitable soil over hard rock. 3. F- Insufficient depth of suitable soil to seansonal water table. 4. f Rates of absorption too slow. 5. F- Insufficient area of acceptable soil for required drainfield, and /or Reverse Area. 6. F- Proposed system too close to well. 7. 1- Other Specify (attach additional pages if necessary) Page �' of Appendix 2 Soil Summary Report GENERAL INFORMATION Date 4 -24 -10 Submitted to Albemarle County Health Department Applicant Sheridan Estate Telephone Number Address 5212 Walnut Level Road Crozet, Virginia 22932 Owner same Address same Location Slam Gate Road Tax Map 26 -33B Subdivision Sheridan Estate Block/Section Lot 2B SOIL INFORMATION SUMMARY • eX(L� 1. Position in landscape satisfactory? jx Yes F- No Describe side slope 2. Slope 10 3. Depth to rock or impervious strata: Max. Min. None x 4. Depth to seasonal water table (gray mottling or gray color) r No Fv Yes inches 5. Free water present (x No F- Yes range in inches 6. Soil percolation rate estimated FX Yes Texture group 1 II (D IV F- No Estimated rate 90 min /inch 7. Permeability test performed r Yes No If yes, note type of test performed and attach Fx Site Approved: Drainfield to be placed at 24, depth at site designated on permit. F- Site Disapproved: Reasons for rejection: 1. F- Position in landscape subject to flooding or periodic saturation. 2. r- Insufficient depth of suitable soil over hard rock. 3. F- Insufficient depth of suitable soil to seansonal water table. 4. 1- Rates of absorption too slow. 5. r Insufficient area of acceptable soil for required drainfield, and /or Reverse Area. 6. F- Proposed system too close to well. 7. F- Other Specify (attach additional pages if necessary) Put, 6 °P-8' Abbreviated Design Form This form is for use with gravity, pump to gravity, enhanced flow, and low pressure distribution (LPD) sewage system designs and when applying for a certification letter or subdivision approval. This abbreviated design covers the Ll primary and reserve area, Lily the primary area, ❑ only the reserve area (check one) for _Sheridan Estate — Lot 2B (Property ID). Design Basis Total length of available area: 100' +501 Total width of available area: _110' Estimated Pere. Rate: 75 at 60" in. (depth) Number of bedrooms (or GPD): 4 l 2 Conveyance Method : Gravl Distribution method (specify): Gravity 3e Dispersal system basis Table 5.4 LGMI required? No (Yes/No) Effluent quality required: Priman (Primary, Secondary, Advanced Secondary) Square feet per bedroom: 596 Area Calculations Number of trenches 5 100's + 6 50's Width of trenches: 3' Reserve required? yes Total trench bottom area required: 2384 Length of trenches: _100' + 50' Center to center spacing: 9' Percent reserve area required: 100 Total width of absorption area required 93' Total trench bottom area provided: 2400 The required width is calculated by multiplying the center -to- center spacing by one less than the number of trenches and adding 1 trench width plus any required reserve area. If the topography is not uniform across the length of the site the trenches will need to flare apart on one end to maintain contour. When this occurs it is necessary to use a center -to- center spacing that accounts for the flair or the installer will not be able to fit the system within the approved area. It is perfectly acceptable to have more area available, especially up and down the slope, than is required. Page _ of AOSE Poru E Revised July 18, 2007 Pa", -?'PE Abbreviated Design Form This form is for use with gravity, pump to gravity, enhanced flow, and low pressure distribution (LPD) sewage system designs and when applying for a certification letter or subdivision approval. This abbreviated design covers the ❑ primary and reserve area, O only the primary area, wily the reserve area (check one) for _Sheridan Estate — Lot 2B (Property ID). Design Basis Total length of available area: 100' Total width of available area: 40' Estimated Perc. Rate: 90 at 24" in. (depth) Number of bedrooms (or GPD): 4 I Conveyance Method : Gravi 3e Dispersal system basis GMP 118A 2 Distribution method (specify)L.— Gravity LGMI required? No (Yes/No) Effluent quality required: Secondal (Primary, Secondary, Advanced Secondary) Square feet per bedroom: _306 Area Calculations Number of trenches 5 Width of trenches: 3' Reserve required? this is reserve Total trench bottom area required: 1224 Length of trenches: 100' Center to center spacing: 9' Percent reserve area required: 100 Total width of absorption area required 39' Total trench bottom area provided: 1500 The required width is calculated by multiplying the center -to- center spacing by one less than the number of trenches and adding 1 trench width plus any required reserve area. If the topography is not uniform across the length of the site the trenches will need to flare apart on one end to maintain contour. When this occurs it is necessary to use a center -to- center spacing that accounts for the flair or the installer will not be able to fit the system within the approved area. It is perfectly acceptable to have more area available, especially up and down the slope, than is required. Page of_ ROSE Pomr E Revised July 18, 2007