Loading...
HomeMy WebLinkAboutSDP201000074 Review Comments Minor Amendment 2010-11-01Philip Custer From: Philip Custer Sent: Monday, November 01, 2010 5:51 PM To: Summer Frederick Subject: Engineering review of SDP - 2010 -00074 Attachments: 11 -1 Escape Lane Sketch.pdf Summer, I have reviewed the minor amendment for the BB &T Bank at Fashion Square Mall (SDP- 2010 - 00074), received 16 September 2010. County Engineering offers no objection to the approval of this site plan application. I will note however that the approved SP application plan shows a distance of 19.25ft between the ATM island and the brick wall. In this minor amendment application, the width is dimensioned as 18ft but actually measures to be 16.5ft at the narrowest point. To me, this modification does not cause the plan to be in violation of the SP Condition (that the development be in general accord with the application plan), but you might want to consider this question yourself or pose it to Zoning. Section 4.12.17.c.2.a mentions a 16ft width being adequate for one direction travelways when a bypass is needed. If you or Zoning are uncomfortable with the reduction in width from the approved plan and are concerned with increased frequency of bottlenecking, I recommend that the applicant stripe the escape or bypass lane(s) (as illustrated in the attached document). Please let me know if you have any questions. Thanks, Phil