Loading...
HomeMy WebLinkAboutSDP201000067 Review Comments Preliminary Site Plan 2010-10-12vIRGIN� County of Albemarle Department of Community Development Memorandum To: Gerald Gatobu, Senior Planner From: John P. Diez, Engineering Review Division: Current Development Date: September 10, 2010 Rev. 1 October 12, 2010 Subject: SDP20100067 Pantops Fire Station - Preliminary Site Plan The preliminary site plan for Pantops Fire Station, submitted on October 4, 2010, has been reviewed. Current Development Engineering has approved the plans with the following conditions: Preliminary Site Plan Comments 1. Please provide source and date of topography and survey. [18- 32.5.6a] (Rev. 1) Comment has been addressed. 2. Please provide a Simple Methods spreadsheet to illustrate removal rate requirements for the proposed site. (Rev. 1) Comment has not been addressed. Please provide the pre- and post- development drainage area for the proposed site. It appears that the area for the proposed SWM pond will suffice for water quantity. However, engineering is concerned about having anything but dirt and vegetation in this area due to having public drainage facility beneath the pond. Engineering recommends one or two biofilters to capture and treat the runoff for water quality and then to be discharged into the pond for water quantity. (Rev. 1) Comment has been addressed. Complete details and calculations will be required during Final Site Plan review. 4. Please provide a demolition plan showing the removal of the existing one -story framed building. (Rev. 1) Comment has been addressed. 5. All disturbance of critical slope require a critical slopes waiver. Please submit a request for a critical slopes waiver for review. [18- 4.2.5b] (Rev. 1) Waiver request has been submitted and is being reviewed. Final Site Plan Comments (For information purposes only) 1. Professional seal must be signed and dated. [18- 32.6.1] 2. A Water Protection Ordinance application and fee must be submitted, along with an Erosion and Sediment Control and Stormwater Management plan. 3. In order to prevent ponding on the northwest side of the structure, a grate inlet should be installed at the center, along with moving the roof drain pipe to the center of the depressed area so as all runoff is captured and directed to the pond. 4. Please provide parking surface per VDOT guidelines. [18- 4.12.15a] 5. A dumpster pad must be provided. You may submit a request to waive this requirement per section 18- 4.12.13f. The requirements of this subsection may be modified or waived in an individual case if the zoning administrator, in consultation with the county engineer, finds that the public health. safety or welfare would be equally or better served by the modification or waiver. 6. Please provide curb and gutter along travelways and in parking areas. A request for waiver may be submitted for review. [18- 4.12.15g] 7. Guardrail must be provided for any steep slopes or drop -offs along parking areas. 8. VDOT approval must be obtained prior to final site plan approval. 9. Please provide General Construction notes. \\ Cob- dts01 \cityviewlnk\Docs\2010 \SDP \SDP201000067 Pantops Fire Station Preliminary \CDE2_psp_JPD_10 -00067 Pantops Fire Station.doc