HomeMy WebLinkAboutSUB201100057 Review Comments Preliminary Plat 2011-06-06vIRG1N� County of Albemarle Department of Community Development Memorandum To: Gerald Gatobu, Current Development Senior Planner From: Phil Custer, Engineering Review Date: June 6, 2011 Subject: SUB - 2011 -00057 Glenmore Farringdon Culdesac Lot- Preliminary Plat The preliminary plat for the 5 acre lot off of Farringdon Road, received 16 May 2011, has been reviewed. Engineering can recommend approval to the plat after the following comments are addressed. 1. The proposed lot is in an area where 3 lots and a culdesac were shown on the approved rezoning plan. In order to plat one large lot in this area, a variation from the Planning Department will likely be needed. 2. This lot is within the jurisdictional area for water and sewer. Please show all existing and proposed utility lines with their existing or proposed easements. [14 -302.5 and 14- 302.13] 3. The topography used in this plat must be at a contour interval no larger than the contour interval available from the county. The county possesses topography with contour intervals of 4ft, so this plat must show 4ft contour intervals. [14- 302.12] 4. Please identify the date of the topographic survey. [14- 302.12] 5. An Erosion and Sediment control plan is currently active in the area. The plan includes the building site within the limits of disturbance. However, if a sanitary sewer line is needed in order for this lot to be constructed, an amendment to the ESC plan (WPO- 2008 - 00036) will be necessary. If the existing ESC plan is close to bond release at the time the sanitary sewer line plan is being prepared, an amendment may not be accepted and a new application will need to be submitted so the first application can be terminated. 6. Because the previously approved road construction plan (WPO- 2008 - 00036) removed approximately the equivalent amount of imperviousness that will be constructed for this lot, no stormwater management will be required for this lot. If this lot is ever subdivided so that it matches the approved rezoning plan, a stormwater facility will likely be needed at the end of the culdesac. El_ppt_PBC_ sub- 20 1 1 -00057 Glenmore Farringdon Culdesac Lot- Preliminary.doc