HomeMy WebLinkAboutSDP201100038 Review Comments Final Site Plan and Comps. 2011-06-28Ellie Ray From: DeNunzio, Joel D., P.E. [ Joel .DeNunzio @VDOT.virginia.gov] Sent: Monday, June 27, 2011 3:04 PM To: Ellie Ray Cc: Philip Custer Subject: SDP - 2011 -00038 Crozet Library Phase I Final SDP - 2011 -00038 Crozet Library Phase I Final Ellie, I have reviewed the referenced plan and have the following comments: 1. The entrance was built to a CG -9A standard during the Main Street construction although the CG -11 is the standard for commercial entrances. The profile needs to be in accordance with the detail shown in the CG -9A standard with the traversable 4 foot minimum space not to exceed 2% and likely will be longer based on the Main Street plan. After the sidewalk, the first profile break needs to be a maximum 3% algebraic difference, -1 %, for a minimum 10 feet and needs to include a parabolic curve. The maximum break at that point can be up to 8% but the grade should not exceed a total of 8% because it's a commercial entrance. Show the trip generation for the library on the plan. Show the horizontal sight line triangles. 4. The minimum width of a commercial entrance is 30 feet in accordance with the VDOT Road Design Manual Appendix F -85. Please let me know if you have any questions. Thanks Joel Joel DeNunzio, P.E. VDOT Culpeper Land Development 434 - 589 -5871 ioel .denunzioCcbvdot.viroinia.4ov