HomeMy WebLinkAboutWPO201100037 Review Comments Erosion Control Plan 2011-06-29ALg�,��
�'IRGINZ�
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4126
Project:
Plan preparer:
Owner or rep.:
Date received:
Date of Comment:
Engineer:
WPO- 2011 - 00037, Glenmore -K2B ESC Plan
Mr. Scott Collins, PE; Collins Engineering
Glenmore Associates L.P.
14 June 2011
29 June 2011
Phil Custer
The ESC plan for Glenmore -K2B, received on 14 June 2011, has been reviewed. The plans cannot be
approved as submitted and will require the following changes.
1. The 30 acre active construction limit will be monitored and enforced by the on -site ESC inspector
in conjunction with the County Engineer. Because of this, agreements in lieu of ESC plans will
not be accepted for lot construction. The current plan will add 3.43acres towards that 30acre limit.
2. The existing site is mostly wooded, not open grass field as described in Existing Condition section
of the narrative.
3. The limits of disturbance does not match up with the construction of a portion of the sanitary
sewer line.
4. Silt fence must not be used across contours because it will act as a diversion. This standard is
broken adjacent to both the water and the sewer line.
5. Construction entrances must drain to a sediment trapping measure. [VESCH 3.02]
6. Please remove the silt fence from the stream.
7. Please provide a Utility Stream Crossing symbol at the sewer line's crossing of the intermittent
stream.
8. Please detail how construction equipment will cross the intermittent stream. Please provide a
Stream Crossing symbol for this method.
9. Please provide Army Corps and DEQ approval of the stream work referenced in the previous two
comments.
10. The ESC bond will be computed after the plan has been approved and the applicant has submitted
a Bond Estimate Request Form to the County Engineer.
File: El esc PBC WPO- 2011 -00037 Glemore K2B.doc