Loading...
HomeMy WebLinkAboutARB201100016 Review Comments Preliminary Site Plan 2011-03-14COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 May 25, 2011 Jo Higgins 2564 Mt. Torrey Rd Lyndhurst, VA 22952 RE: ARB201100016 Restore N' Station Tax Map 5513, Parcel 1 Dear Ms. Higgins: The Albemarle County Architectural Review Board, at its meeting on May 16, 2011, completed a preliminary review of the above -noted request to construct a convenience store with associated fuel pump canopies, and to construct an LED illuminated freestanding fuel sign, a gas pump canopy sign, a building entrance sign, and a wall sign in the north gable. The Board offered the following comments for the benefit of the applicant's next submittal. Please note that the following comments are those that have been identified at this time. Additional comments may be added or eliminated based on further review and changes to the plan. 1. Revise the elevation drawings to resolve the awkward appearance of the floating balcony. 2. Revise the architectural elevations to eliminate the cupola. 3. Revise 8/1 and 12/1 windows to correspond to standard local windows types for either residential or commercial structures. Revise the 16/1 windows to either be large storefront windows or a series of smaller, more residential type windows, such as 6/1 or 4/1. 4. Coordinate the window and door openings on the first and second floors of the east elevation. 5. Remove the faux window openings on the east and west elevations with the transom and shingle sheathing infill. Incorporate an alternate design treatment to eliminate any appearance of blankness along the walls. 6. Simplify, coordinate, and reduce the number of materials used for the building elevations. Limit the material palette to those commonly used for similar structures in the area. 7. Submit a material /color sample for the proposed retractable awning. 8. Include the following note on the site plan: "Dumpsters and equipment located in the dumpster and equipment court area shall not exceed 5' in height." 9. Revise the landscape plan to show plantings along the western portion of the fence closest to the dumpster pad and equipment area. 10. Indicate in the luminaire schedule the color and finish of all light fixtures and light poles for the proposed development. Dark brown, dark bronze, or black are appropriate colors for light fixtures in the EC. 11. Revise the planting scheme along the western parcel boundaryto present a more natural appearance similar to the planting scheme along the EC. Incorporate irregular spacing and diverse plant species, including flowering ornamentals. 12. Revise the rows of Abelia shrubs along the north portion of the parking area closest to the EC, the northwest corner of the parcel, the eastern portion of the development, and flanking the entrance drive, to coordinate and integrate more with adjacent plantings and to present a less linear, more natural appearance appropriate for the Rural Areas. Also, utilize a diverse planting scheme. 13. Coordinate the landscape plan and plant schedule regarding the number of Abelia shrubs proposed on the site. 14. Provide site sections to clarify the extent of visibility of the rear fuel canopy from the EC. Submit a detailed elevation drawing showing proposed materials, color, and signage. Add a note to confirm that the fascia will not be illuminated. 15. Submit drawings /images of the proposed fuel pumps for review. SIGNS Please note the wall sign proposed in the gable of the north elevation does not meet the requirements of the Zoning Ordinance as it exceeds the 30' maximum height allowed for signs on a building in areas zoned Highway Commercial (HC); therefore, this sign is not allowed. 16. Revise the monument sign drawing to show the ledgestone for the base material. 17. Revise the landscape plan to show the type of ground cover proposed around the monument sign and revise the plant schedule accordingly. 18. Indicate on the monument sign drawing the color of the aluminum cabinet frame. 19. Submit a detail of the north elevation, including measurements, showing the exact location and mounting method for the sign above the entrance to ensure the proposed location of the sign meets the EC Sign Guidelines. 20. Submit sign drawings with detailed information for the three signs proposed on the second floor of the east elevation. You may submit your application for continued ARB review at your earliest convenience. Application forms, checklists and schedules are available on -line at www.albemarle.org /planning. Revised drawings addressing the comments listed above are required. Include updated ARB revision dates on each drawing and an ARB approval signature panel. Please provide a memo including detailed responses indicating how each comment has been addressed. If changes other than those requested have been made, identify those changes in the memo also. Highlighting the changes in the drawing with "clouding" or by other means will facilitate review and approval. If you have any questions concerning any of the above, please feel free to call me. Sincerely, Eryn Brennan Senior Planner Cc: Jeffries II LLC P.O. Box 910 Crozet, VA 22932 File