Loading...
HomeMy WebLinkAboutSDP201100057 Review Comments Final Site Plan and Comps. 2011-10-25ALg�,�� �'IRGINZ� COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: The Haven at Stonefield SWM and Site Plan; WPO- 2011 -00070 & SDP - 2011 -00057 Plan preparer: Mr. Herb White, PE; W & W Associates Owner or rep.: Albemarle Place EAAP LLC Date received: 29 August 2011 Date of Comment: 25 October 2011 Engineer: Phil Custer The SWM and site plans for The Haven at Stonefield (WPO- 2011 -00070 and SDP - 2011 - 00057), received on 29 August 2011, have been reviewed. The plans can be approved after the following comments have been addressed: A. Stormwater Management Review Comments 1. Please provide an approval letter from Filterra that the current layout is acceptable to them. I have concerns with a few of the structures not operating well in the field. For instance, the water running in the curb uphill of structure 104.1 would have to reverse direction in order for the Filterra to operate efficiently. A smaller facility on the curb line farther south of Inlet 104 should be looked at. 2. Please provide more spot elevations and draw a flow line on the entrance south of Inlet 131. 3. This application will require that a new Stormwater Management Facility Maintenance Agreement be recorded. Please complete this form and submit it to Ana Kilmer with a $17 recordation fee after reading the instructions online. Please include all parcels contained in this site plan on this agreement. 4. Please provide a completed Bond Estimate Request Form to the county engineer to receive an SWM bond. B. Site Plan Review Comments 1. To be consistent with the variation granted by the Director of Planning on 5/16/2011, all tree wells and planting strips must be at least 5 feet in width. Please draw these wells at 5ft in width as well. 2. Please provide stop signs at all entrances onto Inglewood Drive and at the ends of the travelway east of Inglewood Drive where sight distance will likely be limited by the 6 carriage unit building. Providing a stop sign on the entrance closest to G4 may require a redesign. 3. Please provide "Do Not Enter" signs southwest of Building E2 -III. 4. Please on the northwest and southwest ends of this site plan, please show the grading and curb limits of the proffered future connections to Commonwealth Drive so that we can confirm this site will not negatively affected by such extension. 5. Sidewalks adjacent to parking must be 6ft in width. Otherwise, bumper blocks are necessary. [18- 4.12.16.e] 6. Street furniture must be shown on Inglewood Drive, 1St Street, and 2nd Street as designated by Appendix B of the Code of Development. Location and frequency of street furniture must be approved by county staff. 7. County Engineering recommends redesigning the northeast corner of the parking lot so overland flow relief is provided. Currently, if there the storm sewer system is clogged, a portion of Building E2 -II will be flooded. 8. The Filterra 131.1 is an obstacle in the sidewalk southeast of Building E2 -III. [18- 32.7.2.8] It seems the street tree could be located loft further north. 9. Parallel parking spaces must be 9ft in width. 10. On sheet C -11, please label the depth of each parking stall as 20.1ft per the layout plan and the County Code. 11. The western slope is already graded at a 2:1 slope. In order to establish a lft deep channel, the TOW spot elevations specified by the applicant should be raised by at least lft rather than just the existing grade. The top of wall should be equal to the grade 4 -5ft behind the wall. 12. Please continue SCCI to the grate inlet at the intersection of Main Street and Inglewood Drive. File: E1_swm fsp_PBC _ wpo- 2011 -00070 sdp- 2011 -00057 The Haven at Stonefield.doc