HomeMy WebLinkAboutARB201200011 Review Comments Miscellaneous Submittal 2012-02-29ARCHITECTURAL REVIEW BOARD STAFF REPORT
Project # /Name
ARB- 2012 -11: Shoppers World Renovation
Review Type
Preliminary Review of a Building Permit
Parcel Identification
Tax Map 61Parcel 1C1
Location
On the west side of Route 29 North at Shoppers World Court, across from the Fashion Square Mall and north of
Dominion Drive.
Zoned
Planned Development Shopping Center (PDSC), Entrance Corridor (EC)
Owner /Applicant
FR Shoppers World LLC/Federal Realty (Mark Hendrickson)
Magisterial District
Rio
Proposal
The applicant proposes to renovate the exterior of the shopping center. At Buildings A, B, C, D and E, roofing
shingles will be replaced, metal roofing panels will be painted, and bulkheads and miscellaneous trim pieces will be
painted. Building D renovation also includes the addition of three new tower elements (one for each tenant), wood
beams, trellises, and lighting.
Context/Visibility
The shopping center buildings are set at an angle to the EC. Distance from the buildings to the EC right -of -way varies
from 150' to 500'. The shopping center is visible from the EC, although details of the shorter, more distant buildings
(B and C) and the parts of the buildings under the colonnades, are not very noticeable. The new tower elements
proposed for Building D will be readily visible from the EC.
ARB Meeting Date
March 5, 2012
Staff Contact
Margaret Maliszewski
PROJECT HISTORY
DATE
APPLICATION
RESULT
1975
-
The shopping center buildings predate the establishment of the EC. County records indicate
1975 as the year of construction.
1992 -2011
Various
The ARB has reviewed and approved numerous signs for this shopping center over the years.
2004 -05
ARB -04 -162,
ARB -05 -09
The ARB reviewed and approved revisions to the entrances to the shopping center and its
landscaping.
ANALYSIS
REF
I GUIDELINE
ISSUE
RECOMMENDATION
EC Design Guidelines
9
Building forms and features, including roofs, windows,
The primary features of the renovation
Eliminate the center
doors, materials, colors and textures should be
are the three tower elements for
vertical element from the
compatible with the forms and features of the
Building D. The towers help break up
arched tower.
significant historic buildings in the area, exemplified by
the uniformity of the existing building,
(but not limited to) the buildings described in Appendix
and add rhythm and hierarchy to the
Consider reducing the
A [of the design guidelines]. The standard of
facade.
height of the arched
compatibility can be met through scale, materials, and
tower and adjusting the
forms which may be embodied in architecture which is
The towers are large, particularly the
size of its EIFS trim to
contemporary as well as traditional. The replication of
center tower (49' long x 15' tall),
result in more
important historic sites in Albemarle County is not the
which extends above the top of the
streamlined proportions
objective of these guidelines.
existing roof. When compared to the
as seen in the end towers.
end towers, the center tower appears
somewhat over - scaled, with chunky
Revise the glass in the
detailing. The center vertical element
end towers to an alternate
appears out of scale with the rest of the
material other than EIFS.
arched tower, and it will likely conflict
with future signage.
The end towers include glass at the top.
The original intent was to illuminate
the interior, although the tower is not a
usable space. Without a usable space
requiring illumination, the end towers
would act as beacons rather than as
integrated architectural elements. The
applicant has agreed to revise the glass
to an alternate material.
13
Any appearance of "blankness" resulting from building
The towers help relieve the blankness
None.
design should be relieved using design detail or
of the shopping center that is created by
vegetation, or both.
the uniformity of the colonnade and
roof.
14
Arcades, colonnades, or other architectural connecting
A colonnade exists. The proposal
See below for comments
devices should be used to unify groups of buildings
would augment the existing colonnade
on lighting.
within a development.
at Building D with stone and precast
concrete at the piers, wood trellises and
planters between piers, and light
fixtures.
23
Light should be shielded, recessed or flush - mounted
Two types of light fixtures are
Provide cut sheets and a
to eliminate glare. All fixtures with lamps emitting
proposed: A fixture hung from the
luminaire schedule for all
3000 lumens or more must be full cutoff fixtures.
ceiling of the colonnade and a fixture
mounted on the outer side of the piers.
proposed light fixtures.
Indicate fixture color,
25
Light should have the appearance of white light with
a warm soft glow; however, a consistent appearance
The applicant has indicated that the
lamp type, wattage.
throughout a site or development is required.
fixtures will emit less than 3000
Ensure that the luminaire
Consequently, if existing lamps that emit non -white
lumens, but final styles and colors have
schedule is coordinated
light are to remain, new lamps may be required to
not been chosen.
with the lighting
match them.
elevations. If lamps emit
3000 lumens or more,
ensure that full cutoff
fixtures are proposed.
Sign Guidelines
A comprehensive sign review was completed for this shopping center in 2000. The criteria
Update the
allow channel letter signs in white, red, yellow, green, black and colors comparable to and
comprehensive sign
compatible with existing signs in the center. The criteria also require the signs to be located on
criteria to indicate that
the shingled portion of the mansard roof. With the renovated design, signs will also be proposed
signs may also be located
on the faces of the new towers.
on the faces of the tower
SUMMARY OF RECOMMENDATIONS
Staff recommends the following as the primary points of discussion:
• The design of the tower elements
• Scale
• Detailing
• Color
o Materials
Staff recommends approval of the proposal with the following conditions:
1. Eliminate the center vertical element from the arched tower.
2. Consider reducing the height of the arched tower and adjusting the size of its EIFS trim to result in more streamlined proportions, as
seen in the end towers.
3. Revise the glass in the end towers to an alternate material other than EIFS.
4. Provide cut sheets and a luminaire schedule for all proposed light fixtures. Indicate fixture color, lamp type, wattage. Ensure that the
luminaire schedule is coordinated with the lighting elevations. If lamps emit 3000 lumens or more, ensure that full cutoff fixtures are
proposed.
5. Update the comprehensive sign criteria for the Shoppers World Shopping Center to indicate that non - illuminated tenant panel signs hung
from the ceiling of the colonnade do not require ARB review /approval and to indicate that signs may also be located on the faces of the
tower elements of Building D.
elements of Building D.
Tenant panel signs are proposed to be hung from the ceiling of the colonnade. The applicant has
Update the
indicated that these signs are not intended to be illuminated. Give the position in the colonnade,
comprehensive sign
the lack of illumination, and the distance from the EC, these signs are not expected to be visible
criteria to indicate that
from the EC.
the non - illuminated
tenant panel signs hung
from the ceiling of the
colonnade do not require
ARB review /approval.
SUMMARY OF RECOMMENDATIONS
Staff recommends the following as the primary points of discussion:
• The design of the tower elements
• Scale
• Detailing
• Color
o Materials
Staff recommends approval of the proposal with the following conditions:
1. Eliminate the center vertical element from the arched tower.
2. Consider reducing the height of the arched tower and adjusting the size of its EIFS trim to result in more streamlined proportions, as
seen in the end towers.
3. Revise the glass in the end towers to an alternate material other than EIFS.
4. Provide cut sheets and a luminaire schedule for all proposed light fixtures. Indicate fixture color, lamp type, wattage. Ensure that the
luminaire schedule is coordinated with the lighting elevations. If lamps emit 3000 lumens or more, ensure that full cutoff fixtures are
proposed.
5. Update the comprehensive sign criteria for the Shoppers World Shopping Center to indicate that non - illuminated tenant panel signs hung
from the ceiling of the colonnade do not require ARB review /approval and to indicate that signs may also be located on the faces of the
tower elements of Building D.
TABLE A
This report is based on the following submittal items:
Sheet #
Drawing Name
Drawing Date/Revision Date
-
Diagrammatic site plan
1 -23 -2012
-
"Before" photo
1 -23 -2011
-
Color perspective view
1 -23 -2012
-
Building D — Before
1 -23 -2012
-
Building D & E proposed elevations
1 -23 -2012
-
Building A & B proposed elevations
1 -23 -2012
-
Precedents (photos)
1 -23 -2012
-
Building Sections A & B
1 -23 -2012
-
Building Sections C, D & E
1 -23 -2012
-
Buildings D/E and A/B with accent lighting
1 -23 -2012
-
Materials /color board: Hardi siding, green and yellow; Stone Veneer: Eldorado
Cambria Cliffstone; Manufactured Slate: Davinci Roofing custom blend; Brick
(to match existing); Metal coping: Atas silversmith; Paint: match existing Atas
Mission Red at roof; ElFS: Dryvit Amarillo White #113
1 -23 -2012
-
Light fixture cut sheets — Titan collection
-