Loading...
HomeMy WebLinkAboutSDP201200007 Review Comments Preliminary Site Plan 2012-02-10*—&A County of Albemarle Department of Community Development Memorandum From: Max Greene, Current Development engineering review Date: 10 February 2012 Subject: Homewood Suites (SDP201200007) Preliminary Site plan The preliminary site plan has been reviewed. 1. VDOT approval will be required. 2. Please show the following items on the preliminary site plan: a. Date and source of topography: All topography should be at least visually field verified by the designer within the last year [18- 32.6.6, 14 -302, policy for date] b. Benchmark location, elevation, and datum for topography are required. An existing utility or other known position will suffice. [Policy] c. CG -6 for curbing that will convey stormwater flows. [18- 4.12.15.g] d. loading spaces, 12'x25' (with a minimum aisle width of 24') accessible at all times (not behind parking) [18- 4.12.13] e. Dumpster area appears to trap stormwater flows. drainage will not run across, through, or backwater in dumpster areas [ 18- 4.12.19] f. Areas of the parking lot appear to exceed the 5% slope (in any direction) [18- 4.12.15.c] 3. Prior to final approval please submit the following: a. WPO application, fees, and plans for review. Please note: a permanent diversion through the site until required stabilization is not possible. Please reconsider E &SC perimeter controls prior to WPO submittal. b. Show source of 15" PVC pipe in rear of site. Make sure this is not from off -site source and does not have an existing easement. file: CDDEl_psp_MRG_Homewood Suites.doc