HomeMy WebLinkAboutWPO201200008 Review Comments Mitigation Plan 2012-05-09Philip Custer
From: Philip Custer
Sent: Wednesday, May 09, 2012 6:41 PM
To: Scott Collins (scott @collins - engineering.com) Collins; kirsten @collins - engineering.com; Adam
Long
Cc: Ana Kilmer; Ellie Ray
Subject: Engineering review of Old Trail Creekside III II
Good evening,
I have reviewed the latest submittal of the ESC, SWM, road, and mitigation plans for Old Trail Phase III Phase II (WPO-
2012 -00008 and SUB - 2012 - 00010), received 19 April 2012. The plans require slight modifications, which can be worked
out over email. When all the following changes have been made, please attach all pdfs in one email and send them to
me at the same time:
1. (SWM) The set does not contain a routing of the 100 -year storm as was previously shown on the adequate
channel exhibit. Please provide me with this routing and other supplemental information that was shown on
this sheet but was not included in the latest submittal. This can be provided in 8.5" x 11" pages.
2. (Road) Please show sidewalk on both sides of the typical cross - section on S -2.
3. (ESC and the plat) In sheets ESC -2 and ESC -3, please show the new channel downstream of the biofilter and
expand the limits of disturbance to include it. Also, this work appears on TMP 55E -4 - -A outside of the existing
easement. Both properties (TMP 55 -78 and TMP 55E -4 - -A) will need to be included on the WPO bond. This
easement may also need to be expanded on the current plat and the owner of TMP 55E -4 - -A may need to sign
the cover.
4. (ESC and the plat) It has been brought to my attention that in order to construct this subdivision as designed, a
sewer lateral will need to be built across 55E -4 - -4. There is an existing easement, but in order to grant an ESC
permit, the county must verify that the easement is adequate not to require the owner to be party to the WPO
bond. I'm not sure how long it will take the county attorney's office to review and approve this. Considering the
applicant's time sensitivity to record this plat, other alternatives will likely be quicker. One of those alternatives
is to show a sanitary sewer lateral on the construction plan, and a private easement on the plat, across
Wellbourne and the across the north end of Lot 7 to the new sanitary sewer main. Another is to remove Lot 22
from the plat and the lateral from the construction plan. Lot 22 can later be created with the Phase B plat.
(Mitigation) Eliminate Impact Area #1 and mark this facility with the note: "Sediment Trap and Future Biofilter
Location [17- 320.B] ". Increase Impact Area #2 to include all of Birchwood Hill Road construction in the stream
buffer, even the overlap with the sewer line. The net result is in the applicant's favor, but since there will be
"overmitigation ", I want to make sure it is accurately documented for the next phase.
All other technical aspects of the construction plans and plat have been addressed.
The following administrative items must be noted at this time.
6. (WPO) The last submittal was accompanied by a check for $900 that was entered with the WPO. As of today, 6
ESC or SWM reviews have occurred and 1 mitigation plan has been submitted. This requires $1950 in fees. As
of today, $2100 has been paid to this application. Please let me know the particular reason for the $900
payment. The county may need to process a $150 refund. (A third road fee will not be required because all
changes were graphical.)
7. (SWM) A Stormwater Agreement must be recorded before the plat can be approved or a grading permit can be
provided.
8. (ESC and the plat) Unless existing easements are approved by the County Attorney's Office, all properties
disturbed with this application must be party to the WPO bond —see comments #3 and #4 above. (The road
bond only needs to be posted by the owner of TMP 55 -78.)
The bonds for ESC, SWM, mitigation, and road will be provided soon. The plat cannot be approved by the county until
all bonds are posted.
Please let me know if you have any questions.
Thanks,
Phil
296 -5832 x3072