HomeMy WebLinkAboutSDP201200022 Review Comments Preliminary Site Plan 2012-04-30`J I1 pJ11 �11'] �J, r, �) ifilly Service Authority TO: Megan Yaniglos FROM: Alexander J. Morrison, EIT, Civil Engineer DATE: April 30, 2012 RE: Site Plan Technical Review for: SDP - 2012 - 00022: Albemarle Health and Rehabilitation Center — Preliminary Site Plan Tax Map /Parcel Number: 09100000001200 The below checked items apply to this site. ✓ 1. This site plan is within the Authority's jurisdictional area for: ✓ A. Water and sewer B. Water only C. Water only to existing structure D. Limited service ✓ 2. An 8 inch water line is located approximately 25' distant. 3. Fire flow from, nearest public hydrant, located distant from this site plan, is Gpm + at 20 psi residual. ✓ 4. An 8 inch sewer line is located approximately 450' distant. 5. An Industrial Waste Ordinance survey form must be completed. ✓ 6. No improvements or obstructions shall be placed within existing or future easements. 7. and plans are currently under review. 8. and plans have been received and approved. 9. No plans are required. ✓ 10. Final water and sewer plans are required for our review and approval prior to construction approval. 11. Final site plan may /may not be signed. 12. RWSA approval for water and /or sewer connections. 13. City of Charlottesville approval for sewer. ✓ Comments: • Albemarle Fire & Rescue will require 4 fire hydrants for this development. Show fire hydrants with a maximum travel way separation of 400 feet. One fire hydrant must be within 50 feet of a FDC. • Show looped waterline to support 4 fire hydrants. • Show water meter and relocation of existing water meter (from the service line that crosses the property). Water meters should be on the south side of the building to prevent stagnant water in the water line. • Provide unobstructed ACSA easement from waterline to southwest property line shared with Albemarle County Public Schools for future water connection. 168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698 www.serviceauthoriy.org `J I1 PJ11 �Ijl � ( �) filly Service Authority • Show a stub -out for the future connection. ACSA will provide materials for the stub -out outside of the paved area. • Because you will not have a secondary feed at the time of construction it is highly recommended that you include a wye connection into your domestic system. In the event of a waterline break you would be able to keep water service to your building utilizing water trucks. 168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698 www.serviceauthoriy.org