Loading...
HomeMy WebLinkAboutSDP201200021 Review Comments Final Site Plan and Comps. 2012-06-12*-&A County of Albemarle Department of Community Development Memorandum Project: Westminster Canterbury — 28 parking spaces Minor Amendment (SDP2012- 00021) Plan preparer: Gloeckner Engineering [434- 296 -7612] Owner or rep.: Westminster Canterbury of the Blue Ridge [fax unknown] Plan received date: 3 April 2012 (Rev 1) on and before 11 June 2012 Date of comments: 9 May 2012 (Rev 1) 12 June 2012 Reviewer: Michael Koslow Review coordinator: Sarah Baldwin The second submittal for the Minor Amendment for the Westminster Canterbury site plan (SDP2012- 00022), received on and before 11 June 2012, has been reviewed by engineering staff. This review is for the Minor Amendment and does not include a review of Erosion & Sediment Control or Stormwater Management as submitted with WP02012- 00038. Title Information ,vide waivers for curvilinear narkinL, and one wav travel lanes as indicated on sheet . remove the note if unknown. (Rev 1) Per meeting on 10 May 2012, these notes are acceptable to maintain the history of' approved Westminster Canterbury site development plans. Comment retracted. 2. (Rev]) Please re -title Sheets], 3, 4, and 5 to be "27 Additional Parking Spaces ". Existing Conditions Information 1. Existing topography should be at least visually field verified by designer within 1 year of design submittal [18- 32.6.6,14 -302, Policy for date]. Please review existing field topography and note as much within applicable date on this plan set. (Rev 1) Comment has been addressed with 30 May written comment response. Please provide an existing benchmark location, elevation, and datum for topography. An existing utility or other known position will suffice. (Rev 1) Comment has been addressed. Proposed Plan View Information Please label proposed contour elevations for grading adjacent to parking area entrance on sheet 2. Please include existing topography 50' beyond limits of construction [18- 32.5.6d]. (Rev 1) Comment has been addressed. Please provide VDOT equivalent entrance designations or label all radii and distances for the proposed entrances and curb islands. Existing curb island appears to need to be shown as removed as it is in conflict with proposed exit. (Rev 1) Comment has been addressed. Current Development Engineering Review Comments Page 2 of 2 3. Please provide proposed landscape design or indicate if all proposed disturbed grades will be seeded with no additional trees, bushes, shrubs, or flowers. A planting plan may be required. Please contact the planning agent to verify. (Rev 1) Comment has been addressed. 4. Please provide temporary grading easement or letter of intent from adjacent property owner for proposed grading outside property limits. (Rev 1) Comment has been addressed. 5. (Rev]) Please provide atypical detail for proposed retaining wall shown on sheet 2. Plan Detail Information Please include Albemarle County General Construction Notes on sheet 1 per Design Standards Manual. (Rev 1) Comment has been addressed. Recommend deleting notes on sheet 1 which do not apply to this minor amendment. (Rev 1) Per meeting on 10 May 2012, this is not a requirement. Comment retracted. 3. Please provide a detail for proposed dog -house manholes as identified on sheet 3 (especially plan intent for connection with existing pipe). (Rev 1) Comment has been addressed. Drainage Profiles 1. Please distinguish between existing pipes and structures shown in plan and profile views. (Rev 1) Please note DI #S and DI #9 are existing inlets on drainage profile on sheet 3. Please provide a finished grade line over existing pipe runs. Please move finished grade line label appropriately. (Rev 1) Comment has been addressed. 3. Please adjust leader line to structure DI #7 -C. (Rev 1) Comment has been addressed. 4. Please provide invert elevations for structures DI - #6B, DI - #7B, and DI - #7C. Proposed invert elevations appear to be crossed out. (Rev 1) Comment has been addressed. 5. Please include a note to require inlet shaping for all proposed structures with a 4' or greater drop (appears to apply to all 3 proposed inlets). (Rev 1) Comment has been addressed. 6. (Rev]) Please adjust plan layout for storm sewer system on sheet 3 with 28 parking spaces to match plan layout on sheet 2 with 27parking spaces and proposed retaining wall. Current Development Engineering is available from 2:30 -4 PM on Thursdays to discuss these review comments. Please contact Michael Koslow at 434 - 296 -5832 ext. 3297 or email mkoslowAalbemarle.or to schedule an appointment. C: \Users\mkoslow\Documents \Current Reviews \SDP201200021 Westminster Canterbury 28 parking spaces - Minor Amendment - Copy\E2 mia MAK sdp201200021.doc