The preliminary plat for Glenmore 92 -15 (SUB- 2012 - 00073), received 11 June 2012, has been reviewed.
I can recommend approval to this preliminary plat once the following comments are addressed.
1. The Subdivision Ordinance requires that all single - family detached, lots must be located on a
public road. The current proposal includes a private street and I am unsure whether the Planning
Commission will need to approve the use of a private street since a similar approval was granted in
SUB - 2010 - 00115. If it is determined that Planning Commission authorization of the current
proposal is needed, the applicant must provide a letter requesting a private street per 14 -234.
Since the default private street standards are VDOT standards for streets serving six or more lots,
the applicant should only request the private street through 14- 232.A.1, unless design standard
waivers are also requested. Engineering review will likely not recommend approval of any design
standard waiver.
2. Adjacent to the road cross - section, please state that the design speed of the street is 25mph.
3. The horizontal alignment and street cross - section is acceptable. However, the design of the
culdesac must be approved by the County's Fire and Rescue Department.
4. When an applicant uses county topographic information, he /she should use the critical slope layer
as well. County data shows a small section of critical slopes within the building site for Lot 9.
Please adjust the plat accordingly or provide a supplemental site specific survey for Lot 9.
5. Please provide a conceptual Stormwater Management Plan. The SWM facility layout plan must be
designed to capture as much of the development as practical. Please include the county's modified
simple spreadsheet for each drainage facility. A stormwater management plan for each lot is not
an acceptable proposal.
6. The deed book, page number, and owner of record for Carroll Creek Drive must be identified on
this plat. [14- 302.A.4]
7. The Zoning of TMP 94 -16 is PRD, not R2.
8. The stream buffer note of 14- 302.13.10 must be on the plat.