Loading...
HomeMy WebLinkAboutWPO201200037 Review Comments Erosion Control Plan 2012-07-26�� OF A i" A COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: Giant at Pantops WP0201200037 Plan preparer: Dominion Engineering [fax 979 -16811 Owner or rep.: Hurt Investment Company [fax unknown] Plan received date: 22 June 2011 Date of comments: 26 July 2011 Reviewer: Max Greene The Water Protection Plans (WP0201200037) submitted 22 June 2012 have received Engineering Review and do not appear to meet Albemarle County nor State minimum checklist items for approval. Please adequately address the following comments for final approval: 1. Existing basin and drainage area to basin do not appear to match previously approved plan. Additional drainage area from Hickman Road has been added to basin since previous approvals. Please provide a comprehensive survey to verify compliance to VSMH and show as built conditions, and existing drainage area to basin. 2. Emergency Spillway appears to be the same elevation as Primary Spillway. This does not meet minimum requirements per VSMH. Field survey required. 3. Please provide emergency spillway detail. County Inspector has indicated there are construction concerns with existing spillways. 4. 100 -Year Freeboard does not appear sufficient per VSMH. Field survey required. 5. Spillway details for plan and profile do not appear to match. Field survey required. 6. Existing pond volumes need verification prior to approval. Field survey required. 7. Downstream embankment appears to be in excess of 2:1 slope. Field survey required. 8. Aquatic bench appears too deep per VSMH. 9. Storage /discharge graph of riser does not appear to be correct. 10. Tc for pre and post should not be identical. SCS 24hr storm must be used. Please revise and provide justification. Once these comments have been addressed, please submit 2 copies of the revised plans, calculations, and narratives to Current Development Engineering along with the required review fee and transmittal form. Current Development Engineering is available from 2:30 -4 PM on Thursdays to discuss these review comments. Please contact Max Greene at 434 - 296 -5832 ext. 3283 or email m .-reene @albemarle.ora to schedule an appointment. [17- 204.f] An application for an erosion and sediment control plan that requires modifications, terms, or conditions to be included in order for it to be approved shall be deemed to be withdrawn if the owner fails to submit a revised plan addressing the omitted modifications, terms or conditions within six (6) months after the owner is informed of the omitted information as provided under paragraph (B). Filc: CDDEI_ESC,SWM_MRG_Giant at Pantops.doc