Loading...
HomeMy WebLinkAboutSP201200016 Review Comments Critical Slope Waiver 2012-07-05*—&A County of Albemarle Department of Community Development Memorandum To: Chris Perez, Current Development planning and zoning review From: Michael Koslow, Current Development engineering review Date: 5 July 2012 Subject: UVA Tier III Tower CV825 Cedar Hill (SP201200016) critical slope waiver request The critical slope waiver request has been reviewed. The engineering analysis of the request follows: Description of critical slope area and proposed disturbance: This is a proposed wireless telecommunications facility and includes a critical slope area. The applicant is proposing to include a monopole structure, two equipment cabinet platforms, a future 45 square foot concrete equipment slab within a 600 square foot gravel compound with a proposed retaining wall. Areas (sft) Total project site 1,709 Critical slopes 354 20.7% of site Critical slopes disturbed on site 354 100% of critical slopes Exemptions to critical slopes waivers for driveways, roads and utilities without reasonable alternative locations: This disturbance is not exempt. Compliance with Zoning Ordinance 18 -4.2: "movement of soil and rock" Proper slope construction, control of drainage, and vegetative stabilization should prevent any movement of soil. "excessive stormwater runoff' The proposed telecommunication facility's surface will be pervious, consisting of a layer of gravel over a meshed layer of geo- synthetic fibers. This project is unlikely to cause excessive stormwater runoff. "siltation" Proper stabilization and maintenance can help long term stability. Measures proposed include soil stabilization blankets and matting at the existing steep slopes and silt fence and construction entrance during construction. "loss of aesthetic resource" Eighteen trees are proposed to be removed as part of this project. This should cause a minimal impact to loss of aesthetic resource in the rural area of the county. "septic effluent" This project does not propose any sanitary facilities. Based on the review above, engineering recommends approval of this critical slopes disturbance waiver request. file: C:AUsers \mkoslow\Documents \Current Reviews \SP20 1 2 -000 1 6 UVA Tier III Tower CV825 Cedar MIRE I_csw_MAK_SP- 2012 -00016 UVA Tier III Tower.doc