HomeMy WebLinkAboutWPO201100103 Review Comments Stormwater Management Plan 2012-07-20Philip Custer
From: Philip Custer
Sent: Friday, July 20, 2012 3:13 PM
To: 'Schooley, Christopher (cds7c)'; Eugene Ryang; 'Alan Franklin'
Cc: Joanne Tu Purtsezova; Mark Hopkins
Subject: Boars Head SWM Amendment (WPO- 2011 - 00103)
Good afternoon,
I have reviewed the SWM plan amendment for Boars Head Squash Facility (WPO- 2011 - 00063), received 12 July 2012.
The changes to Biofilter C are approved on the condition that a Minor Site Plan Amendment is approved. At the time
that the minor amendment approval is received, 3 updated copies of this SWM plan amendment should be provided to
me so that I may pass it off to the inspector.
In the minor amendment application, please include profiles for the new and revised drainage facilities. If a change in
horizontal or vertical direction is necessary for the pipe underneath the sidewalk, a manhole structure will be required.
A curb and a curb inlet will likely be needed now that the ditch is being removed. This may result in the water line
having to be relocated. The site plan will also need to show and label a detectable warning surface at each handicap
ramp.
Please let me know if you have any questions.
Thanks,
Phil
296 -5832 x3072