HomeMy WebLinkAboutWPO201200068 Review Comments Erosion Control Plan 2012-08-15i" ,. `IRGINZP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: Plan preparer: Owner or rep.: Plan received date: Date of comments: Reviewer: North Point Sanitary Sewer Extension Townes Site Engineering Corolla Management Corp. 9 August 2012 15 August 2012 Max Greene WP0201200068 [fax unknown] [fax 804 - 748 -2590] The Water Protection Plans (WP0201200068) submitted 9 August 2012 has received Engineering Review and do not appear to meet Albemarle County minimum checklist items for approval. Please adequately address the following comments for final approval: 1. Please update the County notes on the plan. The County notes can be found @ http: // www .albemarle.org /upload/images/ forms_ center /departments /community deyglop ment/forms /design_standards _ manual/Albemarle County Design Standards Manual 02 - 12- 2010.pdf 2. Please make sure all details and notes are legible with resubmittal. 3. Silt fence on parcel 03200- 00- 00 -022EO does not appear to meet the minimum standard requirements per VESCH. A small trap is recommended in the area next to the temporary construction entrance for plan approval. 4. Silt fence shown installed down a slope does not function as designed and should be replaced with a diversion or sediment trapping structure. 5. Please add the Albemarle County Paved Construction Entrance detail to the plan. http:/ / www .albemarle.org /upload/images/ forms_ center /departments /community deyglop ment/ forms /design_standards _ manual/Albemarle County Design Standards Manual 02 - 12- 2010.pdf 6. Please provide additional details for the area of the existing SWM basin on parcel 03200 - 00- 00 -022I0 crossing. The basin appears to be temporarily breached with is proposal and will need to be reconstructed according to the approved design for "Cedar Hill Mini Storage Warehouse ". Please show this on the plans. 7. Plan appears to show a large amount of excess soil on the grading plan. Where is the excess soil going? 8. Weir outlet structure appears too close to the point of inflow and will short- circuit the system. Please show the required 2:1 inlet to outlet per Std. & Spec. 3.13, VESCH. 9. Please show "Stockpile areas" with adequate E &SC protection for "temporary" grading areas. 10. "Existing trees to be removed" are required plantings on the "Cedar Hill Minim Storage Warehouse" Site plan. Area will need to be replanted in accordance with the "Cedar Hill Minim Storage Warehouse" Site plan. Please show this on the plans. Engineering Review Comments Page 2 of 2 Once these comments have been addressed, please submit 3 copies of the revised plans, calculations, and narratives to Current Development Engineering along with the required review fee and transmittal form. Current Development Engineering is available from 2:30 -4 PM on Thursdays to discuss these review comments. Please contact Max Greene at 434 - 296 -5832 ext. 3283 or email mgreene @albemarle.org to schedule an appointment. [17- 204.f] An application for an erosion and sediment control plan that requires modifications, terms, or conditions to be included in order for it to be approved shall be deemed to be withdrawn if the owner fails to submit a revised plan addressing the omitted modifications, terms or conditions within six (6) months after the owner is informed of the omitted information as provided under paragraph (B). File: CDDEI_esc_MRG_North Pointe Sanitary Sewer Extension.doc