HomeMy WebLinkAboutSUB201200127 Review Comments Final Plat 2013-08-07Phone: 434 - 296 -5832
, of ALg�
y� -
C � r'
�'IRGINZP
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Rd. North Wing
Charlottesville, VA 22902
Memorandum
To: Scott Collins
Owner: Central Virginia Real Estate Ventures LLC
From: Brent W. Nelson
Division: Planning
Date: November 15, 2012
Subject: SUB201200127 Glenmore Leake K2 Lots 24 -27 - Final
Fax: 434 - 972 -4126
The Planner for the Albemarle County Planning Division will recommend approval of the final
subdivision plat referenced above once the following comments have been fully addressed. Comments are
those that have been identified at this time. Additional comments may be added or eliminated upon
further review. [Each comment is preceded by the applicable reference to the Subdivision/Zoning
Ordinances and County Code.]
114- 302(A)21 Vicinity map
A map at a scale of one (1) inch equal to two thousand (2, 000) feet showing the property and
its relationship with adjoining land and streets, its relationship with landmarks in the area and, if
the subdivision is a phased subdivision, all other phases of the subdivision for which a final plat
has been approved, in detail adequate to describe the location of the property without field
review.
Initial submittal (10/22/12): Revise the vicinity map by labeling Running Deer Drive.
114- 302(A)31 Existing or platted streets
The location, width and names of all existing or platted streets and all other rights -of -way.
Initial submittal (10/22/12): Revise the plat by labeling Carroll Creek Road and labeling the right -of-
way widths of Farringdon and Carroll Creek Roads.
f14- 302(A)4; 14 -303 (L)1 Public easements/ Public utility, drainage and sight distance easements
The location and dimensions of all existing and proposed public easements outside of a street
right -of -way. Existing easements shall be labeled with the deed book and page number and the
name of the public owner of record. Proposed easements shall be labeled as "dedicated to public
use. "
1 1 —
The location and dimensions of each public utility, drainage and sight distance easement outside
of a street right -of -way; for each existing easement, include a note stating the deed book and
page number.
Initial submittal (10 /22/12): Revise the plat to include the location and dimensions of each public utility,
drainage and sight distance easement outside of a street right -of -way; for each existing easement, include
a note stating the deed book and page number — this includes the 50' wide emergency access easement (to
be abandoned) and the 20'wide overhead and underground electric easement.
[14-302W9144.2.1144.2.21 Building sites on proposed lots
The location, area and dimensions of a building site on each proposed lot complying with the
requirements of section 4.2 of the zoning ordinance. The plat shall also contain the following
note: `Parcel [letter or number] and the residue of Tax Map /Parcel [numbers] each contain a
building site that complies with section 4.2.1 of the Albemarle County Zoning Ordinance. "
Initial submittal (10/22/12): Revise the plat to include the following note: "Lots 24 -27 each contain a
building site that complies with section 4.2.1 of the Albemarle County Zoning Ordinance"
f 14- 302(A)1111 Instrument creating property proposed for subdivision
The deed book and page number of the instrument whereby the property was created, as recorded
in the office of the clerk of the circuit court of the county.
Initial submittal (10 /22/12): Revise the plat to include the deed book and page number of the instrument
whereby the property was created, as recorded in the office of the clerk of the circuit court of the county.
f14- 302(A)12; 14 -3081 Topography
[14-3041 Request for critical slopes waiver
Existing topography at the time of plat submittal at up to twenty [20] percent slope, with a
contour interval that is not greater than the interval on aerial topography available from the
county. The source of topography, including survey date and name of the licensed professional;
or a statement that topography data provided by the county was used Proposed grading, with a
contour interval equal to the intervals of the existing topography, supplemented where necessary
by spot elevations; areas of the site where existing slopes are twenty -five (25) percent or greater.
Existing topography for the entire site with sufficient offsite topography to describe prominent
and pertinent offsite features and physical characteristics, but in no case less than fifty (50) feet
outside of the site unless otherwise approved by the agent. For property in the rural areas zoning
district, the proposed grading shall show all grading on each proposed lot, including access,
clearing and all other lot improvements.
Initial submittal (10/22/12): Revise the plat to include the source of topography, including survey date
and name of the licensed professional; or a statement that topography data provided by the county was
used, proposed grading (maximum five [5] foot contours) supplemented where necessary by spot
elevations; areas of the site where existing slopes are twenty -five (25) percent or greater. Submit updated
critical slope waiver information as requested by reviewing engineer and required by Sectionl4 -304.
114- 302(B)51 Zoning classification
The zoning classification of the property, including all applicable zoning overlay districts,
proffers, special use permits and variances.
�2�
Initial submittal (10/22/12): Revise the plat by removing all references (page 2 of 3) to the proposed
rezoning of TMP 94 -73 and include a reference to ZMA- 2006 -016 and associated proffers on the cover
sheet for the zoning classification.
f14- 302(B)81 Yards
The location of all yards required by this chapter and the zoning ordinance, which may be shown
graphically or described in a note on the plat.
Initial submittal (10 /22/12): Provide the setbacks note in its entirety as required for the Glenmore PRD.
"Setbacks:
a. Front Yard: Depth of front yard shall be no less than twenty -five (25) feet except, in future cottage
sections, the front yard may be reduced to ten (10) feet.
b. Side Yard: Depth of side yard shall be no less than fifteen (15) feet except, in future cottage sections,
the depth of the side yard shall be no less than three (3) feet.
c. Corner Side Yard: Depth of side yard lots located at street intersections with common open space of a
minimum width of fifteen (15) feet between the lot and one of the street's right -of -way may be reduced to
seven and one half (7.5) feet.
d. Rear Yard: Depth of rear yard shall be no less than twenty (20) feet except in cases in which the rear lot
line abuts common open space or the golf course, then the rear yard of such lot may be reduced to ten (10)
feet.
[14-3051 Stormwater management information
Initial submittal (10/22/12): Submit stormwater management information as requested by reviewing
engineer and required by this section.
f 14- 303(H)l Monuments
The location and material of all permanent reference monuments. Monuments found or installed
prior to plat recordation may be referred to if they are permanent and undisturbed. If any
monument required by this chapter will be installed after recordation of the final plat, the
certification of the professional engineer or land surveyor shall so note.
Initial submittal (10/22/12): Revise the plat to include the location and material of all permanent
reference monuments. Monuments found or installed prior to plat recordation may be referred to if they
are permanent and undisturbed. If any monument required by this chapter will be installed after
recordation of the final plat, the certification of the professional engineer or land surveyor shall so note.
114- 303(1)1 Bearing and distance ties
A definite bearing and distance tie between not less than two (2) permanent monuments on the
exterior boundary of the property and further tie to existing street intersection where possible and
reasonably convenient.
Initial Submittal (10/22/12): Revise the plat to include a definite bearing and distance tie between not
less than two (2) permanent monuments on the exterior boundary of the property and further tie to
existing street intersection where possible and reasonably convenient.
f 14- 303(S)l Control points
�3�
At least four (4) control points, evenly distributed across the property and located at survey
property corners, and shown on each sheet depicting the property. At the option of the subdivider,
the control points may be shown on a copy of the final plat, rather than on the original final plat.
Initial Submittal (10/22/12): Revise the plat to show At least four (4) control points, evenly distributed
across the property and located at survey property corners, and shown on each sheet depicting the
property. At the option of the subdivider, the control points may be shown on a copy of the final plat,
rather than on the original final plat.
[Administrative Zoning Review: Proffer Compliance]
ZMA- 2006 -016, ZMA- 1999 - 016( ?), Others( ?)
Initial Submittal (10/22/12): In addition to distribution to the reviewers on the Site Review Committee,
this plat has been distributed to Zoning for administrative zoning review and approval. Those comments
will be forwarded to you as soon as they are received.
[ZMA- 2006 -016 Proffer #11
Initial Submittal (10/22/12): Add the note to the cover sheet of the plat that was formulated in
conjunction with Zoning previously for SUB- 2011 -056, SUB - 2011 -083, and SUB-2011-105. This note is
required for all plats reviewed in the Glenmore Leake sections, present and future.
Section K2 development shall not exceed 110 single family units (ZMA- 2006 -016, Proffer 1). 76 of these
units are in addition to and not counted as part of the total permitted in Glenmore PRD (ZMA- 1999 -016).
Revise the lot tally on Sheet 1 to show that 34 of the new lots available are dedicated to Glenmore for a
net of 55 available to Glenmore Section K2.
ZMA- 2006 -016 Proffer #6
Initial Submittal (10 /22/12): Zoning has indicated that all WPO Plans and SUB plans associated with the
30 acre limit on disturbance need to be explicitly referenced prior to plat approval, including but not
limited to SUB - 2011 -026, SUB- 2011 -056 if and when recorded, SUB - 2011 -083 if and when recorded,
and SUB - 2011 -105 if and when recorded. Engineering will be evaluating the amount of total disturbance,
however all WPOs and SUBS need to be referenced.
�4 �