From: Oleynik, Megan (VDOT) [ Megan .Oleynik @vdot.virginia.gov]
Sent: Friday, November 02, 2012 10:38 AM
To: Megan Yaniglos
Cc: Joel DeNunzio, P.E.
Subject: SDP - 2012 -042 Edenbrook Park Preliminary
Megan,
Joel and I have reviewed the subject plan and have the following comments.
1. Manholes should be relocated outside of the pavement.
2. VDOT Road Design Manual F -84 requires a 50' entrance length where back out parking may interfere with entry
movement, such as with entrances 1 and 3 on Kimbrell Road.
3. Curb extensions /bump outs should have a minimum length of 40' according to VDOT Road Design Manual 131-
49.
4. Crest and sag vertical curves require minimum k values of 12 and 26, respectively.
5. Show stopping sight distances on road profiles. A minimum stopping sight distance of 155' is required for
25mph roads according to VDOT Road Design Manual F -34.
Please let us know if you have any questions.
Thanks,
Megan Oleynik