Loading...
HomeMy WebLinkAboutSDP201200042 Review Comments Preliminary Site Plan 2012-11-02Megan Yaniglos From: Oleynik, Megan (VDOT) [ Megan .Oleynik @vdot.virginia.gov] Sent: Friday, November 02, 2012 10:38 AM To: Megan Yaniglos Cc: Joel DeNunzio, P.E. Subject: SDP - 2012 -042 Edenbrook Park Preliminary Megan, Joel and I have reviewed the subject plan and have the following comments. 1. Manholes should be relocated outside of the pavement. 2. VDOT Road Design Manual F -84 requires a 50' entrance length where back out parking may interfere with entry movement, such as with entrances 1 and 3 on Kimbrell Road. 3. Curb extensions /bump outs should have a minimum length of 40' according to VDOT Road Design Manual 131- 49. 4. Crest and sag vertical curves require minimum k values of 12 and 26, respectively. 5. Show stopping sight distances on road profiles. A minimum stopping sight distance of 155' is required for 25mph roads according to VDOT Road Design Manual F -34. Please let us know if you have any questions. Thanks, Megan Oleynik Engineering Intern VDOT - Culpeper District