HomeMy WebLinkAboutSDP201000031 Review Comments No Submittal Type Selected 2010-05-18II COMMONWEALTH of VIRC NIA DEPARTMENT OF TRANSPORTATION CHARLOTTESVILLE RESIDENCY OFFICE 701 VDOT WAY CHARLOTTESVILLE, VA 22911 GREGORY A. WHIRLEY ACTING COMMISSIONER May 181h, 2010 Mr. Glenn Brooks Department of Engineering and Development 401 McIntire Rd. Charlottesville, VA 22902 Subject: Site Review Meeting Comments May 20th, 2010 site review meeting Dear Mr. Brooks: Below are VDOT's comments on the Site Plans for the May 201h, 2010 Site Review Committee Meeting: SDP - 2010 -00031 First Baptist Church -Maior (Megan Yaniglos) • Will this site cause an increase to traffic on route 605? The road currently has an ADT of 60 trips per day. SDP - 2010 -00034 Earlysville Service Center - Preliminary (Elizabeth Marotta) • This entrance has previously been reviewed and approved. SDP - 2010 -00035 West Village Preliminary Site Plan (Gerald Gatobu) 1. For the proposed road to be eligible for acceptance into the Secondary System of Roads it must meet the connectivity requirements set in Secondary Street Acceptance Requirements. The area type is rural so the road only needs to have multiple connections in varying directions in accordance with 24VAC30 -92 -60 section 3. The future extension must be constructed to the property line. 2. The proposed road needs to show the proposed functional classification and traffic volume anticipated when the land served is fully developed. This includes anticipated traffic from the adjacent property once developed. 3. Road widths need to be in accordance with the values for projected volumes 2001- 4000 in accordance with GS -SSAR. 4. The entrance on the north side of Block A lot 3 needs to show adequate sight distance. WE KEEP VIRGINIA MOVING 5. Commercial entrances need to have a minimum width of 24 feet in accordance with Appendix F of the VDOT Road Design Manual. They also need to have a throat length according to the number of egress lanes. 6. The minimum effective radius on an entrance should be 25 feet in accordance with Appendix F of the VDOT Road Design Manual. 7. Is there a speed table proposed at station 14 +00. Traffic calming should be accomplished through the geometrics of the road and not with physical measures. 8. The swale should not be located between the parking lane and the sidewalk. The sidewalk should be adjacent to the parking with a 3 foot buffer and the swale on other side of the sidewalk. 9. Final plans will need to include drainage calculations and pavement design. 10. If parking lanes are used, they should be continuous and then necked down at the intersections instead of having individual spaces along the road. SUB- 2010 -00049 Nydrie Farm - Preliminary (Megan Yaniglos) 1. Show projected traffic from the subdivision. 2. The entrance to Route 715 needs to show adequate sight distance in accordance with the Commercial Entrance Standards in Appendix F of the VDOT Road Design Manual. 3. Recommend a 20 foot dedication along the frontage of route 715 and 627. 4. The entrance needs to be designed in accordance with figure 4 -8 of Appendix F of the VDOT Road Design Manual. Please request the applicants provide a written description of revisions with re- submissions. If you have any questions or comments, please contact me prior to sharing these comments with the applicants. Sincerely, Joel DeNunzio, P.E. Staff Engineer VDOT Charlottesville Residency 434 - 293 -0011 WE KEEP VIRGINIA MOVING